EN
Introduction and aims: The results of analysis for surface geometry of Weller endoprosthesis heads removed from the aseptic loosening of artificial hip joint are presented in the paper. A dependence between the values of amplitude parameters and time period of endoprosthesis exploitation are shown in this paper. Moreover the dependence between the various amplitude parameters of analysed heads surface is described in the paper. Material and methods: It was tested the surface of 37 heads of Weller endoprosthesis, which were exploited from 5 to 20 years. Measurements of geometrical structure were realized by using the Rank Taylor Hobson Talyscan 150 apparatus. The scanning region of Weller endoprosthesis heads had the range of 1,5-2,0 mm2 scanning velocity about 5,0 mm/s. Obtained data were saved and analysed by the Talymap 3.0 computing program. Results: The effect of exploitation of Weller endoprosthesis heads refers to decreasing the values of analysed parameters St, Sz, Sa and Sds. That fact means not only the worse work conditions in the wear point “polyethylene cup - head” of Weller endoprosthesis but also early occurring of aseptic loosening in implanted artificial joint. Conclusions: The dependence between the parameters Sds and St, and also between the parameters Sds and Sz showed rather little correlation with decreasing trend [p<0,05]. The relations between the parameters values Sz and St describing the heads surface of Weller endoprosthesis and time period of their exploitation showed some significant decreasing dependence [p<0,001]. From comparison of parameters St, Sz and Sds implies that each pair of analysed parameters has negative directly proportional relation.
PL
Wstęp i cele: W pracy przedstawiono wyniki analizy geometrii powierzchni głów endoprotez Wellera usuniętych z powodu aseptycznego obluzowania sztucznego stawu biodrowego. W pracy przedstawiono zależność między wartościami parametrów amplitudy i czasem eksploatacji endoprotezy. Ponadto opisano zależności między różnymi parametrami amplitudy powierzchni analizowanych głów. Materiał i metody: Testowano powierzchnię 37 głów endoprotez Wellera, które były eksploatowane od 5 do 20 lat. Pomiary struktury geometrycznej zrealizowano za pomocą aparatu Rank Taylor Hobson Talyscan 150. Obszar skanowania głów endoprotez Weller miał zakres 1,5-2,0 mm2 z prędkością skanowania około 5,0 mm/s. Uzyskane dane zostały zapisane i przeanalizowane przez program obliczeniowy Talymap 3.0. Wyniki: Wpływ eksploatacji głów endoprotez Wellera odnosi się do obniżenia wartości analizowanych parametrów St, Sz, Sa i Sds. Fakt ten oznacza nie tylko gorsze warunki pracy w punkcie zużycia „polietylenowa panewka - głowa” endoprotezy Wellera, ale także wczesne pojawienie się aseptycznego obluzowania w wszczepionym sztucznym stawie. Wnioski: Zależność między parametrami Sds i St, a także między parametrami Sds i Sz wykazywała raczej niewielką korelację z tendencją malejącą [p<0,05]. Zależność między wartościami parametrów Sz i St opisującymi powierzchnię główek endoprotezy Wellera a okresem ich eksploatacji wykazała istotną zależność malejącą [p<0,001]. Z porównania parametrów St, Sz i Sds wynika, że każda para analizowanych parametrów ma ujemną wprost proporcjonalną zależność.
2
Content available remote Parameters of unimplanted and explanted surfaces of Weller endoprosthesis stems
EN
40 samples of stem surfaces of the Weller endoprosthesis of hip joint removed because of aseptic loosening were tested. The patients between the ages of 61 and 87 were examined and the exploitation time of endoprosthesis ranged from 1 to 20 years. The material analysed was as follows: I group - exploitation 1-3 years (5 surfaces), II group - exploitation 5-8 years (11 surfaces), III group - exploitation 10-14 years (14 surfaces), and IV group - exploitation 16-20 years (10 surface)). Additionally group 0 covered 4 unexploited endoprostheses. We analysed the 2-4 mm2 surfaces of the Weller endoprosthesis stems, with the scan velocity of 500 um/s. A decrease in stem amplitude parameters means some increase in stem microdisplacements in relation to cement. During the first three years, the decrease in the roughness of endoprosthesis surface was larger compared with that in further exploitation period. In the case of unexploited surfaces of stems, the values of fractal dimension are lower (2.34). During exploitation time the Sfd parameter decreases negligibly (2.28-2.24).
3
Content available remote Struktura geometryczna powierzchni zużytych głów endoprotez Wellera
PL
W pracy przedstawiono wyniki badań SGP (St, Są i Sds) zużytych 36 głów sztucznych stawów biodrowych Wellera usuniętych operacyjnie z powodu aseptycznego obluzowania po 5-7 latach (11 głów), 10-14 latach (19 głów) oraz 18-20 latach (6 głów). Skaningi powierzchni głów wykonano indukcyjną głowicą Tałyskan 150 z diamentową końcówką pomiarową firmy Rank Taylor Hobson. Skanowaniem objęto obszar na głowach wielkości 1 x 1,0-1,5 mm2. Otrzymane dane poddano obróbce komputerowej za pomocą programu Talymap Expert. W badaniach stwierdzono znamienne zmniejszenie wartości liczbowych wszystkich badanych parametrów amplitudowych w miarę wzrostu czasu obserwacji [p < 0,001]. Najwyższe wartości liczbowe SGP stwierdzono na powierzchniach eksploatowanych najkrócej, najniższe na głowach usuniętych po 18-20 latach. Z porównania parametrów amplitudowych SGP badanych głów (Sz od St, Sds od St i Sds od Sz) wynika, że pomiędzy nimi występowały znamienne zależności [p < 0,01-0,001]. Ze wzrostem wartości liczbowych jednego parametru zwiększała się wartość porównywanego parametru.
EN
In the paper are described the research results SGP (St, Sa, Sds) of worn cement heads of artificial Weller hip joints operated from 5-7 years (11 heads), 10-14 years (19 heads), and 18-20 years (6 heads). The scanning of head surfaces have been performed with induced Talyskan 150 head equipped with diamond contact tip made by Rank Taylor Hobson Company. The area covered by scanning was 1 x 1,5 mm2. The data received have been handled by computer program Talymap 3.0. The researches results certify that all numerical values of amplitude parameters decrease significantly as duration of observation time rises [p < 0,001]. The highest numeric values of parameters were detected on head surfaces which had been exploited the shortest time and the lowest on the heads exploited the longest time. The significant dependence between parameters results from the comparison of amplitude parameters SGP of heads [p < 0,01 - 0,001]. While numeric value of one parameter turn then increases the numeric value of compared parameter.