Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 3

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  emisja jonów
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
The paper deals with the subject related to the assessment of the influence of the axis angle of the metal components of the hip joint on the emission of cobalt ions. The tribological tests were carried out with the use of a simulator for the examination of hip joint endoprostheses, the structure of which enables the fixation of endoprosthesis components in accordance with the anatomical structure of the human hip joint. During the tests, the simulator performs flexion and extension movements as well as loads occurring in the human hip joint while walking. Loss-wear tests were carried out for nine variants of the “head–cup” system settings. These settings were determined on the basis of CT images obtained from patients after arthroplasty. After the tribological tests were completed, samples of the lubricating fluid with the wear products suspended in it were collected in order to determine the concentration of cobalt ions, which was carried out using the atomic absorption spectrometry method. As a result, the influence of the head antetorsion angle (α) and the acetabular anteversion angle (β) on the concentration of cobalt ions was analysed.
PL
W pracy poruszono problematykę związaną z oceną wpływu kątów elementów endoprotezy stawu biodrowego na emisję jonów kobaltu. Badania tribologiczne przeprowadzono przy użyciu symulatora do badania endoprotez stawu biodrowego, którego konstrukcja umożliwia mocowanie elementów endoprotezy zgodnie z budową anatomiczną stawu biodrowego człowieka. Podczas testów symulator wykonuje ruchy zgięcia i wyprostu oraz obciążenia występujące w stawie biodrowym człowieka podczas chodzenia. Testy zużycia przeprowadzono dla dziewięciu wariantów ustawień układu „głowa–panewka”. Ustawienia te zostały określone na podstawie obrazów CT uzyskanych od pacjentów po endoprotezoplastyce. Po zakończeniu badań tribologicznych pobrano próbki cieczy smarującej z pozostałymi w niej produktami zużycia w celu oznaczenia stężenia jonów kobaltu, co przeprowadzono metodą atomowej spektrometrii absorpcyjnej. W rezultacie przeanalizowano wpływ kąta antetorsji głowy (α) i kąta antewersji panewki (β) na stężenie jonów kobaltu.
EN
Energetic ions emitted from plasmas produced by the interaction of intense laser pulses with solid targets are currently a subject of growing interest due to the possibility of unique applications in accelerator technology, nuclear physics, material science and medicine. Depending on the kind of application, different parameters of the ion fluxes are required, and various conditions of laser-target interaction must be considered. In this paper, selected results of our recent studies of ion emission from plasmas produced by laser pulses of duration from ~ 1 ps to ~ 1 ns and of intensities from 10^10 W/cm^2 to 10^17 W/cm^2 are reviewed. The characteristics of both heavy ion fluxes emitted from massive high-Z targets and proton beams generated from thin foil targets of various structures are presented. Some basic properties of ion fluxes produced in various experimental conditions are discussed. The effect of external magnetic field on the ion emission is demonstrated.
3
Content available remote Site symmetries of rare-earth and transition metal ions in Li₂B₄O₇ glasses
EN
Absorption and emission spectra of Eu and Dy, Yb and Ti ions in Li₂B₄O₇ glasses grown in oxygen and hydrogen gas atmospheres were measured for valency states and lattice-sites in oxygen and hydrogen gas atmospheres were measured for valency states and lattice-sites analysis. For the Li₂B₄O₇ glass doped with Eu²⁺, Eu³⁺ and Dy³⁺ ions (grown in oxidizing and reducing atmospheres), absorption and emission bands due to these ions were investigated before and after gamma irradiation. For the Yb³⁺ - doped Li₂B₄O₇ glass, a week, broad band was observed near the sharp 976,3 nm absorption band. The origin of this band is discussed in comparison with other glasses. Moreover, irradiation experiments using γ-rays were also performed in order to investigate the possibility of valency change of Yb ions. Coexistence of Yb²⁺ and Yb³⁺ ions was observed after gamma irradiation. It was found that Ti⁴⁺ ions, which are produced under oxidizing atmosphere, change to Ti³⁺ ions after gamma irradiation with a dose of 10⁵ Gy. An additional absorption band observed at about 500 nm is due to the Ti³⁺ ions accompanied by charge-compensating vacancy and does not give any emission.
PL
Zmierzono widma absorpcji i emisji jonów Eu, Dy, Yb oraz Ti w szkłach Li₂B₄O₇ otrzymanych w atmosferach tlenu i wodoru, w celu analizy symetrii położeń i stanów walencyjnych. Dla szkieł domieszkowanych Eu²⁺, Eu³⁺ i Dy³⁺ (wzrost w atmosferze utleniającej i redukującej) zmierzono widma absorpcji i emisji przed i po naświetleniu kwantami gamma. Dla szkła domieszkowanego Yb w widmie absorpcji zaobserwowano szerokie pasmo w pobliżu ostrej linii 976,3 nm. Zanalizowano pochodzenie tej linii, porównując szkło Li₂B₄O₇ z innymi szkłami. Ponadto przeprowadzono naświetlenie próbki kwantami gamma w celu zmiennej walencyjności jonów Yb³⁺. Stwierdzono, że jony Ti⁴⁺, które powstały przy wzroście w atmosferze utleniającej przechodzą w jony Ti³⁺ po naświetleniu próbek kwantami gamma dawką 10⁵ Gy. Powstałe dodatkowe pasmo absorpcji ok. 500 nm pochodzi od jonów Ti³⁺ otoczonych oktaedrycznie z kompensującym ładunek wakansem tlenowym i nie daje żadnej emisji.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.