Heat accumulation means denotes the of a material to collect and store inside a specific amount of thermal energy, which can be then returned for a period time from the material. There are many investigations devoted to finding a method to collect heat when there is an excess and to use it when there is a deficit. The parameter determining whether the returned heat long for a term will have an impact on the room temperature, is the time of emission of stored energy. For the specified amount of stored energy, the emission time cannot be too short (in such a case too much heat in the unit time is returned) or too long (in this case a too small amount of heat in the time unit is returned, for example insufficient for heating rooms). The main aim of this research is to investigate the behavior (during cooling) of natural rock materials. On the basis of research and performed calculations the evaluation of tested materials to serve as the heat accumulator was performed. This analysis would allow them to be applied for the production of components, including precast, working at elevated temperatures, in which the accumulation and transfer of heat is important (eg. housing furnaces and fireplaces).
PL
Akumulacja ciepła oznacza zdolność materiału do gromadzenia i magazynowania w jego wnętrzu określonej porcji energii cieplnej, która następnie może być przez pewien okres czasu przez ten materiał oddawana. Szuka się więc sposobów gromadzenia ciepła wtedy, gdy jest jego nadmiar oraz wykorzystania, gdy występuje deficyt. Parametrem, decydującym o tym czy oddający ciepło materiał w sposób długotrwały będzie oddziaływał na temperaturę pomieszczenia, jest czas oddawania (emisji) zgromadzonej energii. Przy danej ilości zgromadzonej energii, czas jej emisji nie może być zbyt krótki (wtedy w jednostce czasu oddawane są zbyt duże ilości ciepła) ani zbyt długi (wtedy w jednostce czasu oddawane są zbyt małe ilości ciepła, niewystarczające np. do ogrzania pomieszczenia). W niniejszej pracy zrelacjonowano eksperyment polegający na badaniu zachowania się, podczas studzenia, naturalnych surowców mineralnych. Na tej podstawie badań oraz wykonanych obliczeń oceniono jego zdolność do akumulacji cieplnej. Pozwoliłoby to na stosowanie ich do wytwarzania elementów, w tym prefabrykatów, pracujących w podwyższonych temperaturach, gdzie jest istotna akumulacja i oddawanie ciepła (np. obudowy palenisk i komików).
2
Content available Heat balance of the military vehicle
EN
In modern combat vehicles there are very often used observation devices with the capability of operating in the infrared. They allow detecting heat emission. It is very important to reduce such situation on the battlefield; therefore generated heat masking or reducing systems are used. The article presents the heat balance of the military vehicle, impact of heat amount on detectability and solutions reducing or changing the thermal image which impedes recognition.
PL
W pracy przedstawiona została propozycja oceny wielkości strumienia ciepła jawnego z powierzchni zabudowanej. Badania prowadzone były w tunelu aerodynamicznym przy przyjętych skalach podobieństwa KL = 100, KU = 2, KTx = 8 i Kt = 50. Turbulencyjny przepływ strumienia powietrza nad wymodelowanym obszarem zabudowy był rejestrowany przy wykorzystaniu wiązki światła laserowego. Określenie współczynnika struktury optycznej C2n pozwoliło ustalić wielkość współczynnika struktury termicznej C2T. Przyjmując profil prędkości wiatru o charakterze logarytmicznym wyznaczono wartość prędkości tarciowej, a w dalszej kolejności funkcji Monina - Obuchowa fT (z/zL). Na podstawie uzyskanych danych oszacowano skalę temperatury Tx i wielkość strumienia ciepła jawnego QH.
EN
The paper presents an assessment method of surface sensible heat fluxes. The study was conducted in wind tunnel with assumed similarity scales: KL = 100, KU = 2, KTx = 8 and Kt = 50. Laser beam was used to record turbulent air flow over modeled built area. Refractive index structure parameter allows determination of the temperature structure parameter. Friction velocity and Monin – Obuchow function were determined assuming logarithmic velocity profile. Obtained data allowed estimation of temperature scale and magnitude of sensible heat fluxes.
PL
Przeprowadzono analizę rozkładu temperatur w przypowierzchniowej strefie Ziemi na podstawie danych satelitarnych NASA (http://earthobservatory.nasa.gov/GlobalMaps/). Bezpośredni wpływ oświetlenia słonecznego, pokryw śniegowych oraz lodów wyeliminowano przez wykorzystanie tylko średnich nocnych temperatur miesięcznych z czerwca, lipca, sierpnia i września z lat 2000 i 2012. Pobierane były obrazy globalne z tego okresu w przedziale EO° do E360° i N-63° do N63°; dla Polski przyjęto lądowy obszar E14° do E25°/N49° do N55° oraz obszar NW Polski od E14° do E18°/ od N51° do N55°. Miesięczne średnie temperatur nocnych były pobierane z całych wymienionych obszarów oraz dla porównania z profili diagonalnych NW-SE i SW-NE. Stwierdzono wyraźne podwyższenia temperatury w obszarach miejskich i przy zbiornikach wód otwartych. Mniej wyraźne, ale nieprzypadkowe odchyłki negatywne temperatur średnich stwierdzono w obszarach spiętrzeń morenowych i w obszarach górskich. Mniejszy wpływ na odchyłki temperatur powierzchni terenu ma zróżnicowanie pokryw roślinnych. Stwierdzona regionalizacja rozkładu anomalii średnich może mieć związek ze zróżnicowaniem intensywności naturalnego strumienia cieplnego Ziemi (por. Szewczyk i Gientka 2009). Badania są dopiero zainicjowane, ale pierwsze wyniki wykazują przydatność tego źródła danych w określaniu: wstępnych parametrów ujęć geotermalnych, temperaturowych anomalii antropogenicznych oraz trendów krótkotrwałych zmian klimatycznych.
EN
The Earth's superficial temperature distribution in Poland was analyzed based on the NASA satellite data (http://earthobservatory.nasa.gov/GlobalMaps/). The direct impact of sunrays, snow cover and ices was eliminated by using only night pictures from the months without snow — June to September 2000 and 2013. Geographically, data images were acquired from images covering the following areas: global EO° to E360°/N —63° to N63°; for Poland E14° to E25°/N49° to N55° and for the NW Poland E14° to E18°/N51 ° to N55°. Average monthly temperature data were collected from the entirety of the mentioned areas and, for the control, from the diagonal profiles NW-SE and SW-NE: Urbanized areas and peripheries of open waters were characterized by higher temperatures then average, while lower than average were temperatures of glacial end moraines and mountain areas. Vegetation cover has a lesser impact on night temperatures on land. The apparent regional distribution of temperature variances may represent some manifestations of variables in the natural heat flow from the deeper subsurface spheres of the Earth (see Szewczyk and Gientka 2009). The presented analyses have only just been initiated, but preliminary results point to the prospective applicability of global temperature data in geothermic studies, land use planning, and delineating of global temperature trends.
PL
W artykule przedstawiono wyniki symulacji wpływu prędkości strumienia wentylacyjnego w wyrobisku na rozwój dymu i emisji ciepła podczas pierwszej fazy rozwoju pożaru przenośnika taśmowego. Symulacja prowadzona była w programie Fire Dynamics Simulator (FDS) z modułem graficznym Pyrosim. Program FDS należy do grupy programów Computational Fluid Dynamics – CFD. Symulację prowadzono dla zmiennych wartości prędkości strumienia powietrza: od 0 m/s, 0,25 m/s, 1 m/s do 3 m/s. Dla przyjętych założeń i uproszczeń wykazano, że relatywnie duże wartości prędkości powietrza mogą się przyczynić, do zmniejszenia chwilowej emisji ciepła podczas pierwszej fazy pożaru, oraz do uniknięcia powstania wstecznego przepływu dymu pod stropem.
EN
The results of simulation into the influence of air stream velocity on smoke spread and heat release during first stage of belt conveyor fire have been presented in the article. Fire Dynamics Simulator (FDS) with graphical mode Pyrosim was the tool of simulation. FDS belongs to the group of Computational Fluid Dynamics software – CFD. Simulation was set for different air velocities: from 0 m/s, 0,25 m/s, 1 m/s to 3 m/s. For given assumptions and simplifications it was proven that relatively high values of air stream velocity can decrease temporary heat release during the first stage of fire and can avoid reversed smoke flow under the roof.
EN
The subject of the paper is heat exchange in the system casting - riser - ambient. The examinations were focused on evaluating temperature dependence of the coefficient of heat exchange from open (not shielded) top surface of riser to ambient. The examinations were carried out on the open surface of cast steel riser, of temperatures 1000-1500°C. On the basis of the performed examinations it was stated that heat emission coefficient changes its mean values by about 50% during feeding process of the mild steel casting, i.e. from about 0.28 in liquid state to about 0.42 at temperatures close to solidus. This wide range of surface heat emissivity changes should be taken into account when boundary conditions are formulated in elaborated models of solidification and in designing risering systems.
PL
Przedmiotem artykułu jest wymiana ciepła w systemie odlew - nadlew - otoczenie. Celem badań było wyznaczenie temperaturowej zależności współczynnika wymiany ciepła z odkrytej, nieizolowanej powierzchni nadlewu do otoczenia. Badania wykonano dla odlewu staliwnego z odkrytym nadlewem, dla zakresu temperatury powierzchni nadlewu 1000-1500°C. Na podstawie wykonanych badań stwierdzono, iż współczynnik emisji ciepła z nieizolowanej powierzchni nadlewu do otoczenia zmienia swą wartość w badanym zakresie temperatury o około 50%, tj. od około 0.26 - 0.30 dla metalu w stanie ciekłym do około 0.42 - 0.46 dla metalu w stanie stałym, w pobliżu temperatury solidus. Powyższy szeroki zakres zmian emisyjności powinien być uwzględniany w budowanym modelach symulacji procesu krzepnięcia i projektowania systemów zasilania krzepnących odlewów.
PL
Ciepło radiogeniczne określane jest standardowo w profilach otworów wiertniczych za pomocą wzoru Rybacha - na podstawie wyników profilowania gęstościowego i spektrometrycznego profilowania gamma. Wymienione profilowania nie są wykonywane we wszystkich otworach wiertniczych, czasem badane są tylko fragmenty profilu otworu. W związku z tym, istnieje konieczność konstrukcji modeli matematycznych uwzględniających zależność wydzielanego ciepła radiogenicznego od litologii skał, ich składu mineralnego i parametrów petrofizycznych, takich jak: porowatość, przewodność cieplna i prędkość propagacji fali akustycznej. Opracowaną metodykę zastosowano do ilościowej oceny ciepła radiogenicznego w profilach wybranych otworów wiertniczych.
EN
Radiogenic heat is normally estimated in well profiles by the means of the Rybach formula - on the basis of the density log and spectral gamma log. These logs are not always performed, and sometimes only part of the well profile is logged. That.s why there is the necessity to generate mathematical models connecting radiogenic heat with the lithology of rocks, their mineral composition and petrophysical parameters such as: porosity, heat conductivity and velocity of elastic wave propagation. The obtained models were used to estimate values of radiogenic heat in the profiles of the investigated boreholes.
8
Content available remote Infra-red measurement of temperature and spectral filters application
EN
The temperature and heat measuring problems as well as infra-red radiation are discussed. The modern termovision systems have been used.
PL
W pracy przedstawiono analizę metod pomiaru temperatury i ciepła. Do pomiarów używano system termowizyjny.
PL
W poprzednim numerze RI rozpoczynając cykl pod wspólnym tytułem „Ogólne zasady projektowania” wskazano, że najlepsze rezultaty przy eliminowaniu emisji ciepła i zanieczyszczeń do środowiska powietrznego pomieszczeń daje pełne obudowanie przestrzeni tych źródeł, połączone z odsysaniem powietrza. W związku z tym obudowy powinny być stosowane wszędzie tam, gdzie jest to tylko możliwe.