The assurance of the electromagnetic compatibility of sensitive smart metering systems and power electronic converters, which introduce high-level electromagnetic interference is important factor conditioning reliable operation of up to date power systems. Presented experimental results have shown that currently binding, frequency domain tests are ineffective for the evaluation of data transmission error hazards. The proposed in this paper mathematical, time-domain model, based on Diophantine equation, enables evaluation of data transmission errors caused by interference introduced by DC-DC power electronic interfaces with deterministic modulation. In the paper there have been presented possible application areas for the proposed model.