This study evaluated the applicability of probability of detection (POD ) analyses to eddy current tests for the detection of corrosions. Forty-three ferromagnetic plates with various corrosions were prepared, and eddy current inspections were performed to gather signals due to the corrosions using an absolute type pancake probe. The probe scanned the surface of the plates two-dimensionally with a constant lift-off to simulate nondestructive inspection of corrosion under insulating coatings. Subsequent POD analyses adopted two models: a conventional one wherein a flaw was characterized using a single parameter, and a multi-parameter model based on the combinational use of numerical simulations and measurements. The analyses demonstrated that the conventional model would overestimate the probability of detecting small corrosions. In contrast, the multi-parameter model characterized POD more reasonably while its confidence interval was comparable to that of the conventional model.
PL
Dokonano oceny przydatności analiz prawdopodobieństwa wykrywania (POD ) do wykrywania korozji na podstawie badań metodą prądów wirowych. Przygotowano czterdzieści trzy płytki ferromagnetyczne z różnym stanem skorodowania. Następnie przeprowadzono inspekcje metodą prądów wirowych i zebrano sygnały uzależnione od korozji za pomocą absolutnych sond typu „pancake coil”. Sonda skanowała powierzchnie płyt w dwóch wymiarach na stałej wysokości nad materiałem, tak by zasymulować nieniszczącą inspekcję korozji w elementach pokrytych powłokami izolacyjnymi. W kolejnych etapach analizy POD przyjęto dwa modele: konwencjonalny, w którym wada była charakteryzowana za pomocą pojedynczego parametru, a także model wieloparametrowy oparty na kombinacyjnym zastosowaniu symulacji numerycznych i pomiarów. Analizy wykazały, że model konwencjonalny prowadził do przeszacowania prawdopodobieństwa wykrycia małych korozji. Natomiast model wieloparametrowy charakteryzował POD bardziej racjonalnie, a jego przedział ufności był podobny jak w przypadku modelu konwencjonalnego.
EN
Magnetic adaptive testing is a powerful way of nondestructive evaluation. Minor magnetic hysteresis loops are systematically measured and evaluated. In the present work this technique was applied for detection of local thinning of ferromagnetic plates. The same plate with a given artificial slot was tested by different size magnetizing yokes. A definite maximum of magnetic descriptors was found, as a function of yoke size, which made possible the optimization of the yoke size for a given size of defect. The character of the maximum also revealed that the measurement is not sensitive for the geometrical parameters: the same yoke is suitable for detection of defects in a wide range. It was proved by simulation that the change of the magnetic flux density in the yoke − due to local thinning − was responsible for the observed effect. Good correlation was found between simulation and experimental data. The result of this work will help to find the optimal parameters of the experimental arrangement.
PL
Magnetyczne testy adaptacyjne są skutecznym sposobem oceny nieniszczącej. W ich trakcie mniejszościowe pętle histerezy magnetycznej są systematycznie mierzone i oceniane. W niniejszej pracy zastosowano tę technikę do wykrywania miejscowego przewężenia płytek ferromagnetycznych. Ta sama płyta ze sztucznymi defektami została zbadana przy wykorzystaniu jarzma magnetyzującego o różnych rozmiarach. Określono maksymalną liczbę deskryptorów magnetycznych, zależnych od wielkości jarzma, co umożliwiło optymalizację rozmiaru jarzma dla danej wielkości defektu. Uzyskana charakterystyka ujawniła również brak wrażliwości wyników pomiaru na parametry geometryczne: to samo jarzmo nadaje się do wykrywania defektów w szerokim zakresie. Udowodniono, że za obserwowany efekt odpowiedzialna była zmiana gęstości strumienia magnetycznego w jarzmie - będąca wynikiem lokalnego przerzedzania. Stwierdzono dobrą korelację między symulacją a danymi eksperymentalnymi. Uzyskane wyniki umożliwią wyznaczenie optymalnych parametrów układu pomiarowego.