Treatment of Municipal wastewater by Electrocoagulation (EC) process using punched aluminium and zinc electrodes was studied in a batch EC cell reactor. Response surface methodology (RSM) based on Central Composite Design (CCD) was utilized to optimize the operating parameters for the removal of % Total Suspended Solids (TSS) and % Chemical Oxygen Demand (COD) from Municipal Sewage. Effect of operating parameters such as Electrode Distance (x1), Electrolysis Time (x2) and Voltage (x3) has been optimized for the removal of TSS and COD. The prediction of removal percentage of TSS and COD in various Operational circumstances is done by using Quadratic model. The significance of each operating parameter was computed by Analysis of variance (ANOVA). To achieve the maximum removal of % TSS and % COD, the optimum conditions were Electrode distance(x1)-3 cm, Electrolysis Time (x2)-70.299 minute and Voltage (x3)-6.5V. It was observed that the performance of electrocoagulation process increased up to 61.45% for COD removal, and 73.73% for TSS removal using punched electrode compared to plane electrodes.
EN
The efficiency of the electrocoagulation process for the removal of phosphate ions (PO43--P) has been analyzed using a batch full-scale reactor with aluminum electrodes. The effects of the flow rate through the reactor applied current density, and reactor volume were the focus of the study. The initial (PO43--P) concentration was reduced by 90% after 90 min of reactor operation time. Additionally, a three-dimensional numerical model for PO43--P removal via the electrocoagulation process is developed that includes the processes of phosphate adsorption and desorption on coagulated/flocculated particles, along with particles settling. Numerical model parametrization relies on the results from the experiments.
EN
Due to the increasing problem resulting from environmental pollution with heavy metals, great emphasis is placed on the development of removal methods of these pollutants from the environment. This study presents a literature review on the methods for the removal of nickel ions from aqueous solutions such as sorption, especially using low-cost sorbents which are very popular in 21𝑠𝑡 century, electrochemical processes and membrane techniques. It is often impossible to use a single technique for efficient removal of heavy metals from wastewater as the process depends on many factors, such as wastewater composition, pH, temperature and many others. The aim of this review is to present some selected removal techniques of nickel(II) from wastewater from the point of view of their efficiency and applicability.
EN
The removal of arsenic from groundwater by continuous electrocoagulation (EC) using combined Fe-Al electrodes at its natural temperature (16.1±0.2 °C) was comprehensively evaluated. The results obtained indicated that all studied Fe-Al electrode combinations were able to reduce As concentration below 10 μg/dm3. Nevertheless, the Fe-Fe-Al-Fe electrode combination was the most suitable due to its highest arsenic removal capacity (0.354 μg As/C) for the lowest charge loading 68.4 C/dm3. The consumption of Fe was 0.0339 kg Fe/m3 and of Al electrodes 0.0145 kg Al/m3. The operating cost was estimated at 0.182 €/m3. The increase of the groundwater temperature by 8 °C from its natural temperature influenced increase of the Fe and Al electrodes dissolution rate by 30% and 17%, respectively and that of As removal efficiency by 16%. The residual Fe and Al concentrations in 500 dm3 of treated groundwater were below WHO guideline values for drinking water. Long-term field operation of the pilot-scale continuous EC reactor is required to validate effectiveness, reliability and robustness of the EC technique for arsenic removal from groundwater confirmed in laboratory conditions.
EN
This paper presents the outcomes of tests of aggregates obtained from pulp and paper industry wastewater treatment using the electrocoagulation method. The test wastewater was treated on a laboratory scale with a recirculation system. Along with the wastewater treatment parameters, the fractal properties of the obtained aggregates were determined and their size was specified. The following wastewater parameters were tested: COD, turbidity and colour. For the conducted process, the fractal dimensions fell within the range of 1.30-1.70 at 0.1 A current. The applied current and electric charge flowing through the solution determined the efficiency of wastewater treatment, and impacted the structure, size and fractal dimensions of the obtained aggregates.
PL
W pracy przedstawiono efekty badań agregatów uzyskanych w wyniku oczyszczania ścieków celulozowo-papierniczych metodą elektrokoagulacji. Modelowe ścieki oczyszczano w laboratoryjnej skali, używając systemu recyrkulacyjnego. Wraz z wyznaczeniem parametrów oczyszczania ścieków określano właściwości fraktalne otrzymanych agregatów i oznaczano ich rozmiar. Badano takie parametry ścieków, jak: ChZT, mętność, barwę. Dla tego procesu uzyskane rozmiary fraktalne mieściły się w przedziale 1,30-1,72 przy natężeniu prądu 0,1 A. Zastosowane natężenie prądu oraz ładunek elektryczny przepływający przez roztwór wyznaczały efektywność oczyszczania ścieków i wpływały na strukturę, wielkość i rozmiar fraktalny otrzymanych agregatów.
7
Content available remote Electrochemical treatment of olive mill waste powered by photovoltaic solar energy
EN
The proposed photovoltaic electrochemical (PV-EC) process combines autonomous and environmentally friendly photovoltaic solar energy with the capability of the combined electrocoagulation/electrooxidation process to effectively remediate toxic olive mill wastewaters and simultaneously produce electrolytic hydrogen. The photovoltaic array can be connected directly to an electrochemical reactor without batteries increasing, in this way, system sustainability and eliminating the environmental threat of poor battery disposal management. The PV-EC system is proved versatile according to the instantaneous solar irradiation by adjusting the wastewater flow rate to the current intensity supplied by the photovoltaic array. Operating parameters affecting the efficiency of the proposed process, such as wastewater flow rate, conductivity, current density, electroprocessing time and solar irradiance were studied and optimal conditions were investigated. The experimental results showed that the initial COD of 21000 mg/dm3 and turbidity of 162 NTU of the olive mill waste sample, were effectively reduced to 122 mg/dm3 and 0 NTU, respectively, after treating the wastewater by both, batch wise and continuously operated electrocoagulation and electrooxidation or combination of the two processes. The proposed process is a safe method for effective treatment of toxic and recalcitrant wastes, such as oily olive mill wastewaters, especially for applications in remote and isolated locations with lack of electric grid.
EN
Two methods of Reactive Black 5 dye removal were compared in this work, namely electrocoagulation (EC) and one based on spontaneous electrochemical oxidation of zero-valent iron (ZVI). Both methods are based on electrode processes and the sorption process and allow to achieve a similar effectiveness of dye removal. In the case of ZVI, however, a longer contact time or a greater surface area of the electrodes applied is necessary. In turn, the ZVI enables to conduct the processes of dye removal with no requirement for an external source of electric current (lower exploitation inputs). The study demonstrated that the application of both the ZVI method and EC is especially advisable in the case of lower initial concentrations of dye in the solution, i.e. the higher the concentration, the lower the contribution of electrode processes in dye removal from the solution and the greater the contribution of sorption processes.
PL
W ramach niniejszej pracy porównano dwie metody usuwania barwnika Reactive Black 5. Metodę elektrokoagulacji (EC), oraz metodę opartą na samorzutnym elektrochemicznym utlenianiu żelaza na 0 stopniu utlenienia (ZVI). Obie metody wykorzystują procesy elektrodowe oraz procesy sorpcji, umożliwiając uzyskanie podobnej efektywność usuwania barwnika. W przypadku ZVI wymagany jest jednak dłuższy czas kontaktu, lub większa powierzchnia zastosowanych elektrod. ZVI umożliwia jednak przeprowadzenie procesów usuwania barwy, bez konieczności stosowania zewnętrznego źródła prądu (mniejsze nakłady eksploatacyjne). Badania wykazały, że zastosowanie zarówno metody ZVI i EC ma szczególne uzasadnienie w przypadku niższych stężeń początkowych barwnika w roztworze. Im wyższe stężenie, tym udział procesów elektrodowych w usuwaniu barwy roztworu jest mniejszy a przewagę zyskują procesy sorpcji.
EN
The results of municipal wastewater treatment by chemical coagulation with PIX and electrocoagulation in a recirculation system with aluminum electrodes were discussed and interpreted. Those processes were analyzed as: a) preliminary processing before biological treatment, or b) the only treatment procedure. The results of chemical coagulation and electrocoagulation indicate that both methods guarantee the required level of phosphorus and suspended solids removal from wastewater. Despite the above, the COD of treated wastewater decreased to only 200 mg×dm–3 which exceeds the norm for effluents discharged from treatment plants (125 mg×dm–3). Our results indicate that municipal wastewater treatment cannot rely solely on chemical coagulation and/or electrocoagulation. In successive parts of the study, wastewater was treated with significantly smaller doses of a ferric coagulant (PIX) and an aluminum electrocoagulant (Al electrodes). The above treatments lowered the phosphorus load of wastewater to a level ensuring its nearly complete removal in successive stages of biological treatment. The practical application of the resulting database was evaluated in view of the existing regulations as well as more stringent requirements which could be introduced in the future, in particular with regard to total phosphorus loads.
PL
W pracy opisano i zinterpretowano rezultaty procesów oczyszczania ścieków miejskich koagulowanych chemicznie PIX-em oraz elektrokoagulowanych recyrkulacyjnie na elektrodach glinowych. Procesy te potraktowano jako: a) etap wstępny, przed biologicznym oczyszczaniem badanych ścieków oraz b) jedyne i ostateczne oczyszczanie ścieków. Wyniki badań procesu koagulacji chemicznej oraz elektrokoagulacji badanych ścieków pokazały, że metody te zapewniają wymagany poziom usunięcia zawiesin i fosforu z oczyszczanych ścieków. Jednakże ChZT tak oczyszczonych ścieków obniżało się tylko do ok. 200 mg·dm–3 przy wymaganym poziomie 125 mg·dm–3 w odpływie z oczyszczalni. Fakt ten nie pozwala więc traktować koagulacji chemicznej lub/i elektrokoagulacji jako jedynego i ostatecznego etapu oczyszczania badanych ścieków miejskich. Stąd w dalszej części badań ścieki traktowano znacznie mniejszymi dawkami koagulantu żelazowego (PIX) i elektrokoagulantu glinowego (elektrody Al). Prowadziło to do częściowego usunięcia fosforu, zapewniając takie obniżenie poziomu P, aby kolejny etap biologicznego oczyszczania mógł zapewnić stężenie tego biogenu w odpływie bliskie zeru. Dokonano oceny wartości aplikacyjnej uzyskanej bazy danych w świetle aktualnych norm i uwarunkowań, jak również w szerszej perspektywie zaostrzenia wymagań w zakresie stopnia oczyszczenia ścieków, szczególnie w zakresie usuwania fosforu.
PL
Przedstawiono istotę metody elektrokoagulacji w zastosowaniu do rozdziału emulsji O/W. Wykorzystano możliwości diagramu Venna, wskazując na złożoność możliwych interakcji mechanizmów procesów składowych. Skoncentrowano się na analizie i ocenie stanu wiedzy w zakresie modelowania elektrokoagulacji - stwierdzając brak liczbowego zachowania proporcji pomiędzy modelami deterministycznymi oraz stochastycznymi. W konkluzji wskazano na konieczność dalszych badań wykorzystujących podstawy systematyki modelowania matematycznego, ze szczególnym uwzględnieniem potencjału środowiska MOSAIC.
EN
Bases of electrocoagulation method applied in oil-in-water emulsion breaking are presented in the paper. The Venn diagram was used in the presentation of constituent processes interactions. The state-of-the-art in the field of electrocoagulation modeling was analyzed and evaluated. A lack of proportion between deterministic and stochastic modeling was ascertained. A necessity of further investigations with the application of systematic mathematical modelling was indicated, especially with the use of MOSAIC environment.
PL
Zużyte ciecze obróbkowe stosowane w obróbce wiórowej i ściernej stanowią wielokomponentowy odpad, który musi być bezwzględnie unieszkodliwiony przed zrzutem do ścieków. Przedstawiono rozważania teoretyczne oraz wyniki badań w zakresie doboru materiału elektrod do neutralizacji zużytych emulsji olejowych metodą elektrochemiczną opracowaną w IZTW. Określono optymalny skład elektrod z uwagi na kryteria minimalnego zużycia energii elektrycznej i maksymalnego jednostkowego wydatku procesu.
EN
Cutting fluids used in machining are the multicomponent waste product which must be necessarily rendered harmless before disposed into the sewer. Theoretical analysis and experimental results concerning a material choice of electrodes for neutralization of used oil emulsions by the electrochemical method worked out at IZTW are presented. The optimum composition of electrodes was determined in a context of minimum electrical energy usage and maximum unit process efficiency.
EN
Wastewater coagulation and electrocoagulation were investigated as sorption processes involving colloidal sorbents such as (Al(OH)3)n, (Fe(OH)3)m and (Fe(OH)2)p. An attempt was made to fit experimental data to two popular sorption models. Based on a statistical and mathematical analysis of the obtained results, the Langmuir model of chemical adsorption was regarded more probable than the Freundlich model. The highest maximum adsorption of phosphorus in the analyzed wastewater was achieved with the use of PIX, and the lowest adsorption maxima were reported for an iron electrocoagulant. PAC was most effective in reducing COD of wastewater. PAC and PIX delivered higher adsorption maxima for compounds responsible for COD than aluminum and iron electrocoagulants.
EN
The current study focused on the treatment of a ternary mixture of dyes which includes Disperse Blue 56 (DB56), Basic Yellow 28 (BY28) and Acid Violet 90 (AV90) using the electrocoagulation (EC) process with iron electrodes. In the presence of all dye molecules, the optimum pH was found to be 6, optimum NaCl concentration was 3000 mg/dm3 and optimum current density was 8.66 mA/cm2. Under the optimized conditions in the case of 100 mg/dm 3 each dye concentration, the average colour removal efficiency was reached 93%. Dye concentration dependent highest COD removal efficiency was measured as 88.70% at 150 mg/dm3 dye concentration.
EN
Decolourization of tartrazine (C.I. Acid Yellow 23, AY23) in aqueous solutions has been investigated by coupling electrocoagulation and ZnO photocatalyst methods and also by a comparison between ZnO, UV, EC, UV/ZnO, UV/EC, and EC/UV/ZnO systems in the removal of AY23 as a model contaminant. Results indicated that the decolourization efficiency was in order of EC/UV/ZnO > UV/EC > EC > UV/ZnO > ZnO > UV. Combining EC with UV/ZnO can trigger the Fenton or Fenton-like reaction, which accelerates the rate of decolourization. Desired operating conditions for decolourization of 40 mg·dm-3 AY23 solution in EC/UV/ZnO process were [ZnO] 0=650 mg·dm-3, [NaCl] = 800 mg·dm-3, light intensity = 31/2 W·m-2, current density = 120 A·m-2, electrodes distance = 15 mm, pH = 6.29, stirring rate = 900 rpm and electrodes of steel 304/A1, which yielded 99.70% colour removal in 5 min of treatment time.
PL
Celem niniejszych badań było porównanie efektów usuwania związków fosforu (ortofosforanów) z wód z dodatkiem ortofosforanów, z wykorzystaniem dwóch metod: metody elektrokoagulacji (z wykorzystaniem procesów elektrochemicznych z użyciem prądu stałego) i metody roztwarzania metali (z wykorzystaniem procesów korozyjnych).
EN
There is a search in progress for some efficient methods of removing biogenic compounds from the treated sewage. Unquestionably, effective methods of phosphorus compounds removal include precipitation methods. The most common is the chemical precipitation method based on applying iron, aluminium or calcium salt to the solution and electrocoagulation. These methods utilise low solubility of metal phosphates and their sorption on the surfaces of the forming agglomerates. The real mechanism is quite complicated and consists of transforming phosphorus compounds into insoluble forms, and then separating them from the sewage by flotation, sedimentation, filtration. The method of iron solution should also be accounted into similar physical and chemical methods. The main difference between the aforementioned methods lies in the way of applying the precipitation agent to the solution. The method of iron solution is based on similar premises as the electrocoagulation method, however, metal ions here are dissolved into the solution as a result of spontaneous corrosion processes and, due to the further transformations in the sewage environment, they are to be responsible for phosphorus removal. The article presents comparative tests on a laboratory scale. The electrocoagulation method and metal digestion method were compared with regard to the effectiveness of orthophosphates removal from synthetic sewage. The comparison of both methods suggests that they can bring similar results of removing phosphorus (ortophosphates) from sewage. The process of reduction of concentration of orthophosphates in sewage occurs faster when the electrocoagulation method is used. However, with a longer test duration, better results are achieved using the metal digestion method. It was also noted that both methods introduce different amounts of iron into the solution. The methods differ with regard to the amount of iron remaining in the sewage in a suspended form. This indicates a better use of iron ions in the metal digestion method and it slightly limits the problem of an excessive amount of sludge.
PL
Celem pracy było zbadanie możliwości usuwania sulfonamidów ze ścieków za pomocą procesów koagulacji chemicznej i elektrochemicznej. Zamierzano również optymalizować proces elektrokoagulacji ze względu na usuwania sulfonamidów. W trakcie badań stosowano próbki rzeczywistych ścieków komunalnych aplikowanych mieszaniną sulfadiazyny, sulfanilamidu, sulfametoksazolu i sulfatiazolu o stężeniach od 1 do 10 mg/dm3. Jako koagulant chemiczny stosowano wyłącznie roztwór FeCl3. Skuteczności koagulacji wyznaczano na podstawie obniżenia mętności ścieków oraz stopnia usunięcia wybranych do badań sulfonamidów. Porównano efekty uzyskiwane metodą koagulacji chemicznej i elektrokoagulacji oraz określono w szerokim zakresie wpływ pH i zastosowanej dawki koagulantu. W przypadku elektrokoagulacji określono dodatkowo wpływ rodzaju zastosowanej anody, gęstości prądowej, czasu trwania elektrolizy, natężenia prądu oraz wyjściowego stężenia sulfonamidów. W trakcie badań określono również wydajność prądową procesu. Stwierdzono, że zarówno klasyczna koagulacja chemiczna, jak i elektrokoagulacja są mało efektywnymi metodami usuwania sulfonamidów ze ścieków. W przypadku elektrokoagulacji można uzyskać nieznaczne zwiększenie usunięcia sulfonamidów, obniżając natężenie prądu i przedłużając czas trwania elektrolizy. Stwierdzono również, że proces usuwania sulfonamidów ze ścieków zachodzi bardziej efektywnie z użyciem anody wykonanej z żelaza niż z glinu. Ponadto konieczne jest każdorazowe eksperymentalne ustalanie optymalnej wartości pH roztworu poddawanego elektrokoagulacji.
EN
The aim of this study was to evaluate the possibility of removal of sulfonamides from wastewater using chemical and electrochemical coagulation processes. It was also intended to optimize the process of electrocoagulation from the viewpoint of sulfonamides removal. In the experiments, mixtures of sulfadiazine, sulfanilamide, sulfamethoxazole and sulfathiazole at concentrations from 1 to 10 mg/dm3 were added to real wastewater. FeCl3 solution was used as a chemical coagulant. Effectiveness of coagulation was determined based on the reduction in turbidity of wastewater and the degree of removal of selected sulfonamides. Moreover, the effects obtained by chemical coagulation and electrocoagulation were compared and effect of a wide range of pH and applied coagulant dose were determined. In the case of electrocoagulation the specific additional effect, such as the type of anode used, current density and intensity, time of electrolysis, and the initial concentration of sulfonamide were determined. In these experiments, the current efficiency of the process was also estimated. It was found that both the classical, chemical coagulation and electrocoagulation are low effective methods for the removal of sulfonamides from wastewater. In the case of electrocoagulation, a slight increase in the removal of Usuwanie sulfonamidów ze ścieków metodą elektrokoagulacji 485 drugs can be obtained by reducing current intensity and prolonging the time of electrolysis. The sulfonamides removal from wastewater occurred more efficiently with the use of iron than aluminum anode. Moreover, the experimental determination of the optimal pH in solution before electrocoagulation process was necessary each time.
PL
W niniejszej pracy przedstawiono wyniki elektrochemicznego oczyszczania ścieków celulozowo-papierniczych. Elektrolizę prowadzono w układzie statycznym z użyciem elektrod glinowych. Badania prowadzono przy dwóch wartościach gęstości prądu na elektrodach: 3,125 i 6,25 mA/cm2. Po elektrokoagulacji i sedymentacji mierzono w roztworze ChZT, mętność, barwę oraz zawiesiny. Jednocześnie określono właściwości fraktalne otrzymanych agregatów-kłaczków osadu ściekowego i oznaczono ich rozmiary fraktalne.
EN
Results of the electrochemical treatment of pulp and paper wastewater have been described in this paper. The electrolysis was conducted in static system on aluminium electrodes. The wastewater purification was carried out at two values of the current density 3.125 and 6.25 mA/cm2. After electrocoagulation the COD, turbidity, suspended solids and color of the supernatant were measured. The fractal dimension of the aggregates-flocs of the sludge obtained was determined too.
EN
Results of the electrochemical treatment of pulp and paper wastewater have been described. The electrolysis was conducted in static system on aluminium electrodes. The wastewater purification was carried out at two values of the current density 3.125 mA/cm2 and 6.25 mA/cm2. After electrocoagulation the COD, turbidity, suspended solids and color of the supernatant were measured. The fractal dimension of the aggregates-flocs of the sludge obtained was determined, too. The examined process of statical electrocoagulation turned out to be an efficient method for pulp and paper wastewater purification. The aggregates-flocs measured were recognized as self-simil objects.
PL
W niniejszej pracy przedstawiono wyniki elektrochemicznego oczyszczania ścieków celulozowo- -papierniczych. Elektrolizę prowadzono w układzie statycznym, z użyciem elektrod glinowych. Badania prowadzono przy dwóch wartościach gęstości prądu na elektrodach 3,125 mA/cm2 i 6,25 mA/cm2. Po elektrokoagulacji i sedymentacji mierzono w roztworze ChZT, mętnosć, barwę oraz zawiesiny. Jednoczesnie określono właściwości fraktalne otrzymanych agregatów-kłaczków osadu ściekowego i oznaczono ich rozmiary fraktalne. Badany proces elektrokoagulacji okazał się skuteczną metodą oczyszczania ścieków celulozowo-papierniczych. Badane agregaty-kłaczki były obiektami „samopodobnymi”.
19
Content available Statyczna elektrokoagulacja ścieków modelowych
PL
Przedstawiono wyniki elektrochemicznego oczyszczania ścieków modelowych. Porównano parametry oraz efekty elektrolitycznego oczyszczania ścieków w warunkach chronopotencjometrycznych (CHRP), tj. przy stałym natężeniu prądu (I = const), oraz chronoamperometrycznych (CHRA), tj. przy stałym napięciu (U = const). Elektrolizę prowadzono w układzie statycznym z użyciem elektrolizera z elektrodami glinowymi. Zastosowano 6-elektrodowy (3 katody i 3 anody) elektrolizer. Po elektrokoagulacji i sedymentacji osadu w roztworze oznaczano chemiczne zapotrzebowanie na tlen ChZT, mętność, barwę, zawiesiny oraz stężenie fosforu ogólnego.
EN
This paper presents the results of electrochemical treatment of model wastewater. Parameters and results of electrolytic treatment of the model wastewater under chronopotentiometric (CHRP) conditions, ie at constant current (I = const), and under chronoamperomtric (CHRA) conditions, ie at constant voltage (U = const), were compared in the study. Electrolysis was performed in a static system, using an electrolyser with aluminium electrodes. Six-electrode (three cathodes and three anodes) electrolyzers were applied. Chemical oxygen demand (COD), color, turbidity, suspended solids and total phosporus concentration were measured after electrocoagulation and sludge sedimentation. The process of static electrocoagulation was found to be an effective method for model wastewater treatment.
EN
This study presents the results of electrochemical treatment of model wastewater. It compares the parameters and the results of wastewater electrolysis performed by chronopotentiometric electrocoagulation (CHRP) at constant current intensity (I = const) and chronoamperometric electrocoagulation (CHRA) at constant voltage (U = const). Electrolysis was carried out in a static system with the use of an electrolyzer with aluminum electrodes. A six-electrode electrolyzer (three cathodes and three anodes) was applied. The chemical oxygen demand (COD), turbidity, color intensity, suspended solids and total phosphorus concentration of the solution were determined after electrocoagulation and sludge sedimentation.
PL
Przedstawiono wyniki elektrochemicznego oczyszczania ścieków modelowych. Porównano parametry oraz efekty elektrolitycznego oczyszczania ścieków w warunkach chronopotencjometrycznych (CHRP), tj. przy stałym natężeniu prądu (I = const) oraz chronoamperometrycznych (CHRA), tj. przy stałym napięciu (U = const). Elektrolizę prowadzono w układzie statycznym z użyciem elektrolizera z elektrodami glinowymi. Zastosowano 6-eIektrodowy (3 katody i 3 anody) elektrolizer. Po elektrokoagulacji i sedymentacji osadu w roztworze oznaczano chemiczne zapotrzebowanie na tlen ChZT, mętność, barwę, zawiesiny oraz stężenie fosforu ogólnego.