Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Powiadomienia systemowe
  • Sesja wygasła!

Znaleziono wyników: 2

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  elektrochemiczny
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
The innovative approach to the issues of integration of an electricity storage, heat storage and an electrode heating boiler in the heating system in this paper is presented. In recent years, a growing share of renewable energy sources in heating has been observed, which may result in the dynamics of electricity price variability being greater and more frequent than in daily and annual periods. This may apply in particular to the price of heat from electrode boilers. The proposed solution to optimize heat prices at an acceptable level for end users, consisting in connecting an electrode heating boiler with heat and electricity storage facilities is presented.
PL
W artykule przedstawiono innowacyjne podejście do zagadnień integracji magazynu energii elektrycznej, magazynu ciepła i elektrodowego kotła ciepłowniczego w systemie ciepłowniczym. W ostatnich latach można zaobserwować rosnący udział odnawialnych źródeł energii w ciepłownictwie, co może spowodować, że dynamika zmienności cen energii elektrycznej będzie większa i częstsza niż w okresach dobowych oraz rocznych. Może to dotyczyć w szczególności ceny ciepła z kotłów elektrodowych. W artykule przedstawiono propozycję rozwiązania dla optymalizacji cen ciepła, na akceptowalnym poziomie dla odbiorców końcowych, polegające na połączeniu elektrodowego kotła ciepłowniczego z magazynami ciepła i energii elektrycznej.
EN
Aim: The purpose of this article is to help designers of fire detectors with the selection of a carbon monoxide (CO) sensor for a multi-sensor fire detector. Academic work on detectors provides an abundance of material about sensors suitable for CO analysis. Each sensor has its advantages and disadvantages. Therefore, choosing a suitable sensor is quite difficult. The authors, based on their extensive experience in the development and production of devices for gas analysis and fire detectors, propose most adequate solutions. Introduction: Current devices for discovering a fire, work on the principle of detecting smoke, often incorporating a temperature sensor. However, these have many disadvantages. They do not function in a discerning way in relation to smoke (aerosols, water vapour, cooking vapour and dust are all identified as smoke). A CO fire detector is free of these shortcomings, since it is selective and reacts to CO. For this reason many perspective European norms and international standards emerged, which recommend CO analysis for detection of fires. Obviously, high concentrations of CO can occur in areas where people smoke, where heating appliances utilising solid and gaseous fuels are used, in garages and in underground car parks. Multi-Sensor Detectors with two methods of detecting fire, CO and smoke, compensate shortcomings of each method. It can be confidently stated that through a simultaneous response from both detection methods, a fire will be dealt with at an early stage of development and resources will not be sidetracked by dust, water vapour, aerosols or high concentration of CO. For detection of CO, existing standards recommend the use of electrochemical sensors. Methods: The article describes the technical parameters of the most appropriate electrochemical sensors for monitoring of CO. These are electrolytic, based on acidic electrolyte and metal oxide semiconductors, namely Nap-508 (505) and TGS2442. The principles of operation and recommended circuit connection are suitably described in the article. The sensors are specially designed for use with gas fire detectors and were tested in accordance with requirements for fire detectors. It is noted that metal-oxide sensors have the most acceptable performance characteristics, across the broadest temperature range, long period of validity and absence of aggressive substances in composite elements. Among its disadvantages is a relatively high power consumption ~ 15 mW. Conclusions: Examined prospects for the development and production of metal oxide semiconductor sensors. It is indicated that the use of micro and nanotechnology in the manufacture of sensors will solve the problem of reducing energy consumption to a level sufficient for the production of self-contained smoke detectors powered by batteries. At present, Figaro has developed a sensor TGS8410 with an average power consumption of 0.087 mW.Aim: The purpose of this article is to help designers of fire detectors with the selection of a carbon monoxide (CO) sensor for a multi-sensor fire detector. Academic work on detectors provides an abundance of material about sensors suitable for CO analysis. Each sensor has its advantages and disadvantages. Therefore, choosing a suitable sensor is quite difficult. The authors, based on their extensive experience in the development and production of devices for gas analysis and fire detectors, propose most adequate solutions. Introduction: Current devices for discovering a fire, work on the principle of detecting smoke, often incorporating a temperature sensor. However, these have many disadvantages. They do not function in a discerning way in relation to smoke (aerosols, water vapour, cooking vapour and dust are all identified as smoke). A CO fire detector is free of these shortcomings, since it is selective and reacts to CO. For this reason many perspective European norms and international standards emerged, which recommend CO analysis for detection of fires. Obviously, high concentrations of CO can occur in areas where people smoke, where heating appliances utilising solid and gaseous fuels are used, in garages and in underground car parks. Multi-Sensor Detectors with two methods of detecting fire, CO and smoke, compensate shortcomings of each method. It can be confidently stated that through a simultaneous response from both detection methods, a fire will be dealt with at an early stage of development and resources will not be sidetracked by dust, water vapour, aerosols or high concentration of CO. For detection of CO, existing standards recommend the use of electrochemical sensors. Methods: The article describes the technical parameters of the most appropriate electrochemical sensors for monitoring of CO. These are electrolytic, based on acidic electrolyte and metal oxide semiconductors, namely Nap-508 (505) and TGS2442. The principles of operation and recommended circuit connection are suitably described in the article. The sensors are specially designed for use with gas fire detectors and were tested in accordance with requirements for fire detectors. It is noted that metal-oxide sensors have the most acceptable performance characteristics, across the broadest temperature range, long period of validity and absence of aggressive substances in composite elements. Among its disadvantages is a relatively high power consumption ~ 15 mW. Conclusions: Examined prospects for the development and production of metal oxide semiconductor sensors. It is indicated that the use of micro and nanotechnology in the manufacture of sensors will solve the problem of reducing energy consumption to a level sufficient for the production of self-contained smoke detectors powered by batteries. At present, Figaro has developed a sensor TGS8410 with an average power consumption of 0.087 mW.
PL
Cel: Celem artykułu jest udzielenie wskazówek konstruktorom czujek pożarowych odnośnie wyboru czujników tlenku węgla w komorze wielosensorowej czujki pożarowej. W monografiach poświęconych tej tematyce znaleźć można wiele czujników nadających się do analizy CO. Każdy czujnik ma swoje zalety jak i wady. W związku z tym wybór odpowiedniego czujnika jest dość trudny. Autorzy, na bazie wieloletniego doświadczenia w projektowaniu i produkcji przyrządów do analizy gazowej i czujek pożarowych, zaproponowali najbardziej adekwatne rozwiązania. Wprowadzenie: Obecnie do wykrywania pożarów bardzo często wykorzystywane są czujki dymu (zwykle z czujnikiem temperatury). Mają one jednak wiele wad – nie działają w sposób selektywny na dym (rozpoznają jako dym aerozole, parę wodną, parę powstającą przy gotowaniu, kurz). Czujka pożarowa CO nie ma takich wad, ponieważ reaguje wyłącznie na CO. Dlatego powstało wiele perspektywicznych norm europejskich i standardów międzynarodowych, które do wykrywania pożarów przewidują analizę CO. Oczywiście, duże stężenia CO mogą powstać w pomieszczeniach, w których pali się papierosy, również tam gdzie znajdują się urządzenia ciepłownicze na paliwo stałe lub gazowe, w garażach i parkingach podziemnych. Wielosensorowe czujki, wykorzystujące dwie komory wykrywania pożaru – CO i dymu, rekompensują wady każdej z tych komór. Przy jednoczesnej aktywacji obu, można z pewnością stwierdzić, że mamy do czynienia z pożarem we wczesnym stadium rozwoju, a nie z kurzem, parą wodną, aerozolem lub po prostu dużym stężeniem CO. Do wykrywania CO odpowiednie nomy rekomendują użycie czujników elektrochemicznych. Metody: W artykule opisano parametry techniczne najbardziej odpowiednich do kontroli CO czujników elektrochemicznych na bazie elektrolitów kwasowych i półprzewodników tlenkowych, a dokładnie Nap-508 (505) и TGS2442. Opisano również zasady pracy i zalecane schematy połączeń. Czujniki te były opracowywane specjalnie do wykorzystania w pożarniczych czujkach gazu i przeszły wszystkie badania zgodnie z wymogami dla czujek pożarniczych. Zaznaczono, że czujniki tlenkowe mają najbardziej akceptowalne charakterystyki eksploatacyjne – najszerszy zakres temperatur, długi termin ważności, brak w składzie elementów środowiska agresywnego. Do ich wad należy względnie duże zużycie energii ~ 15 mW. Wnioski: Rozpatrzono perspektywy rozwoju technologii produkcji półprzewodnikowych czujników tlenkowych. Wskazano, że zastosowanie mikro- i nanotechnologii przy produkcji tych czujników rozwiązuje kwestię zmniejszenia zużycia energii do poziomu dostatecznego do przygotowania autonomicznych czujek pożarniczych zasilanych baterią. Już teraz firma Figaro opracowała czujkę TGS8410 za średnim zużyciem prądu 0,087 mW.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.