Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 2

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  electron capture detector
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
1
Content available remote Detection of atmospheric hydrogen using ECD detector doped with N2O
EN
Atmospheric concentrations of molecular hydrogen are commonly measured with the aid of commercial reduction gas analysers (RGA). An alternative technique of H, detection has been proposed and tested. It is based on commercial automated gas chromatograph equipped with a μ-ECD detector doped with N2O. The main advantage of the presented method is its suitability for high-precision monitoring of atmospheric H2. Typical precision of single analysis, which was obtained in the tests of the system, is in the order of l nmol mol-1. This value is comparable to the precision offered by commercial RGA detectors. The (j-ECD detector investigated in this study revealed linear response in the range of H, concentrations encountered in atmospheric monitoring. The main disadvantage of the method is high sensitivity of the &mu-ECD detector to the impurities in gases used in the analytical system.
PL
Pomiary stężenia wodoru cząsteczkowego w atmosferze są prowadzone na świecie od wielu lat ze względu na wpływ wodoru na budżet innych gazów, w tym także gazów czynnych w efekcie cieplarnianym. Najczęściej wykorzystuje się do tego celu detektory rtęciowe, które jednak z powodu znacznej nieliniowości nie są rozwiązaniem optymalnym. W niniejszej pracy zaprezentowano alternatywną technikę pomiaru zawartości H2 w atmosferze, w której wykorzystano detektor wychwytu elektronów domieszkowany podtlenkiem azotu. Drogą eksperymentalną wyznaczono warunki pracy detektora zapewniające wysoką precyzję pomiaru wodoru (ok. 1 nmol mol-1) przy bardzo dobrej liniowości w pełnym zakresie pomiarowym stężeń tego gazu w troposferze.
EN
In analytical methods based on external standards, different averaging and interpolation methods yield different precision and accuracy. Gas chromatography measurements of freon F-l 1 in air were used to illustrate the influence of different averaging and interpolation methods on the accuracy and precision of measurements. The following methods: the average values of the standard peak areas for 6, 12 and 24 measuring points, the Newton 2-point interpolation method, and the Lagrange 3-point and 5-point interpolation were used and compared. It is shown that for an instrument of good stability the Newton 2-point interpolation method is usually sufficient. For an instrument of poor stability the 5-point Lagrange interpolation method is shown to yield the best precision and accuracy.
PL
W metodach analitycznych opartych na standardzie zewnętrznym różne sposoby uśredniania i interpolacji wpływają na dokładność i precyzję. W pracy na przykładzie chromatograficznych ciągłych pomiarów stężenia freonu F-11 w powietrzu pokazano wpływ metod uśredniania i interpolacji na dokładność i precyzję pomiarów. Porównano metodę uśrednionych wartości powierzchni pików standardu z 6, 12, 24 punktów pomiarowych oraz metody interpolacji: 2-punktową Newtona, 3-punktową i 5-punktową Lagrange'a. Pokazano, że dla stabilnej pracy aparatury pomiarowej 2-puktowa metoda interpolacji Newtona jest wystarczająca. Dla mniej stabilnej pracy aparatury metoda 5-puktowej interpolacji Lagrange'a pozwala uzyskać lepszą dokładność i precyzję pomiarów.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.