The aim of the present study was to develop a relationship to evaluate grip force using the electromyogram (EMG) in isometric anisotonic conditions. The EMGs of the flexor digitorum superficialis (FDS) and the extensor digitorum (ED) were recorded in 3 flexion-extension positions of the wrist (30° flexion, 30° extension, and 60° extension) associated with 3 positions of the forearm (70° pronation, prono-supination, and 70° supination). For each position, the participants had to follow linear ramp targets (2 rates of increase and decrease) displayed on an oscilloscope. The results show the best fit is a quadratic type force-EMG relationship. Some aspects such as the rate of force variation and the forearm and wrist positions are then discussed along with the limitations of the relationship.