Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 4

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  electromagnetic transient
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
During the operation of EHV lines, the overwhelming proportions of single-phase short circuits can be eliminated in the cycle of a shortterm no-current pause, followed by the restoration of the normal circuit. Thus, SPAR refers to the most important measure that increases the reliability of EHV power transmission. The success of elimination of arc short circuits in the SPAR cycle on the one hand, are determined by the characteristics of the secondary arc arising in long air gaps, and on the other hand - the effectiveness of used on lines of methods for reducing secondary arc currents and recovering stresses in the place of arc burning after its extinction. Implementation of SPAR is difficult the presence of recharge of the short circuit from the side of the non-disconnected phases. The paper shows how by proper adjustment of the operating parameters that determine the conditions for extinguishing the secondary arc we get an additional reduction in losses in the transmission line due to more accurate compensation of charging power.
PL
Podczas eksploatacji linii najwyższych napięć, przeważająca część zwarć jednofazowych może być wyeliminowana w cyklu krótkotrwałej przerwy bezprądowej, po której następuje przywrócenie normalnej pracy. JSPZ jest więc najważniejszym środkiem zwiększającym niezawodność przesyłu energii elektrycznej w sieci najwyższych napięć. O powodzeniu likwidacji zwarć łukowych w cyklu JSPZ z jednej strony decydują charakterystyki łuku wtórnego powstającego w długich przerwach powietrznych, a z drugiej strony skuteczność stosowanych na liniach metod ograniczania prądów łuku wtórnego i odtwarzania napięć w miejscu wystąpienia łuku po jego zgaśnięciu. Realizację JSPZ utrudnia obecność wyładowań zwarciowych od strony faz nie rozłączonych. W artykule pokazano jak poprzez odpowiednie dobranie parametrów pracy określających warunki gaszenia łuku wtórnego uzyskujemy dodatkowe zmniejszenie strat w linii przesyłowej dzięki dokładniejszej kompensacji mocy obciążającej.
EN
This paper presents fast transient analysis application for HV power systems with shunt reactors. It is proposed how to speed up analysis of transient processes by using digital filters method and modelling of power lines by wave equations. Proposed methodology enables to transform complicated power system by the abundance of elements to the simplified equivalent and adequate system. It is investigated auto-reclosing operation cases during the fault period, circuit breaker’s phase asynchronous switching influence to overvoltages and overcurrents.
PL
Przedstawiono aplikację do analizy szybkich stanów przejściowych w systemach elektroenergetycznych WN (wysokiego napięcia) z dławikami kompensacyjnymi. Pokazano jak przyspieszyć analizę za pomocą filtrów cyfrowych i modelowania linii elektroenergetycznych równaniami falowymi. Metodologia polega na zastąpieniu złożonego systemu elektroenergetycznego równoważnym układem uproszczonym. Analizowano operacje automatycznego ponownego zamykania po eliminacji zwarć oraz wpływ niejednoczesnego łączenia faz przez wyłącznik na przepięcia i przetężenia.
EN
The future of smart grid protections is related to identification of fast electromagnetic transient in the electric grid. Many algorithms are developed over the world; however some physical processes are common for the overhead transmission line which makes influence to the algorithms reliability. The aim of the article is to show the corona influence on the traveling wave based line protection distance to the fault measurement error. Transmission line model with corona effect was used as the digital filter. Distance to the fault calculation errors dependence on applied voltage trigger level for different overhead line was presented. The influences of environmental conditions to the measurement error were investigated.
PL
Celem artykułu jest pokazanie wpływu zjawiska korony na błąd pomiaru na podstawie fal wędrownych odległości wystąpienia uszkodzenia linii. Przedstawiono dla różnych linii napowietrznych zależność błędów obliczeń odległości do miejsca uszkodzenia od przyjętego poziomu napięcia wyzwalającego. Badano wpływ warunków środowiskowych na błąd pomiaru.
PL
W artykule przedstawiono zagadnienie modelowania układu generator indukcyjny (klatkowy) - sieć elektroenergetyczna dla celów symulacji elektromagnetycznych stanów przejściowych, przydatnych m.in. z punktu widzenia oceny parametrów jakości zasilania. W modelu uwzględniono układy energoelektroniczne w postaci kompensatora kluczującego D-STATCOM i łącznika hybrydowego (HTS), umożliwiającego tzw. soft-start generatora. W odniesieniu do układu D-STATCOM, który może stanowić środek poprawy jakości zasilania, tj. prewencji zapadów napięcia i kompensacji mocy biernej, zaproponowano procedury optymalizacji parametrów sterujących kompensatora, m.in. z punktu widzenia minimalizacji wahań napięcia w punkcie jego przyłączenia podczas skokowych zmian napięcia wywołanych np. zwarciem w sieci.
EN
The paper discusses the problem of electromagnetic transients simulation analysis (e.g. for the quality of energy supply estimation) with use of the model of the system: induction (squirrel cage) generator-power network. The simulation model comprises the power electronics-based compensator D-STATCOM or the hybrid transfer switch enabling so called soft-start of the generator. Considering the D-STATCOM, which may be an additional mean of voltage sags prevention and reactive power compensation, the procedures of compensator parameters optimization have been proposed in order to minimize voltage fluctuations in the point of common coupling (PCC) during sudden voltage changes caused e.g. by a fault in the network.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.