Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 3

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  electricity quality
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
Striving for the so-called climate neutrality, i.e. the reduction of carbon dioxide emissions resulting, inter alia, from the production of electricity, is now a great opportunity for the development of widely understood sources of distributed generation, such as wind farms or photovoltaic farms. These sources, however, are characterized by high variability and a work profile that is difficult to predict, which may adversely affect the power grid to which they are connected. The purpose of the research described in this article is to assess the impact of the reconfiguration of the MV network with distributed generation on the voltage values in its nodes. The article describes the course of research and the results of simulation tests for the real existing 15 kV distribution grid with different variants of generation units and loads.
PL
Dążenie do tzw. neutralności klimatycznej, czyli redukcja emisji dwutlenku węgla powstającej między innymi wskutek produkcji energii elektrycznej jest obecnie dużą szansą dla rozwoju szeroko rozumianych źródeł generacji rozproszonej, takich jak farmy wiatrowe czy fotowoltaiczne. Źródła te charakteryzują się jednak dużą zmiennością i trudnym do przewidzenia profilem pracy, co może niekorzystnie wpływać na sieć elektroenergetyczną, do której są podłączone. Celem badań opisanych w niniejszym artykule jest ocena wpływu rekonfiguracji sieci SN, w której występuje generacja rozproszona, na wartości napięć w jej węzłach. Opisano przebieg badań i podano wyniki eksperymentów symulacyjnych rzeczywistej, istniejącej sieci 15 kV, z różnymi wariantami pracy jednostek wytwórczych i różnymi obciążeniami sieci.
PL
W artykule przedstawiono wpływ oświetlenia LED na jakość pobieranej energii elektrycznej. LED-owe źródła światła zostały podzielone na trzy podstawowe grupy. Pierwsza, to oświetlenie domowe, do których zaliczamy różnego rodzaju wymienne żarówki. Druga grupa, to oprawy przemysłowe stosowane w biurach, zakładach przemysłowych, czy w budynkach użyteczności publicznej. Trzecia grupa, to oprawy stosowane do oświetlenia zewnętrznego ulic, skrzyżowań, chodników, parków. Przetestowano kilkanaście różnego rodzaju źródeł LED-owych, w których zmierzono prąd, napięcie oraz moc czynną, bierną i pozorną podstawowej harmonicznej, jak również wyższe harmoniczne prądów i napięć. Na tej podstawie sporządzono wykresy procentowej zawartości wyższych harmonicznych prądów oraz THDi pobieranego z sieci elektroenergetycznej. Przedstawiono przesunięcia kąta fazowego pomiędzy napięciem i prądem dla podstawowej harmonicznej skutkującym poborem mocy biernej pojemnościowej. Zarejestrowano również przebiegi prądów i napięć pokazujące nie tylko odkształcenie prądu, ale również charakterystykę rozruchu opraw przemysłowych i drogowych.
EN
The article presents the impact of LED lighting on the quality of electricity consumed. LED light sources have been divided into three basic groups. The first is home lighting, which includes various types of replaceable bulbs. The second group includes industrial luminaires used in offices, industrial plants or public utility buildings. The third group includes luminaires used for outdoor lighting of streets, crossroads, sidewalks and parks. A dozen or so different types of LED sources were tested, in which the current, voltage and active, reactive and apparent power were measured, as well as the higher harmonics of currents and voltages. On this basis, graphs of the percentage of higher harmonic currents and THDi collected from the power grid were drawn up. The phase angle shifts between voltage and current for the fundamental harmonic, resulting in the consumption of capacitive reactive power, are presented. Current and voltage waveforms were also recorded, showing not only the current distortion, but also the starting characteristics of industrial and road luminaires.
EN
The increase in the number of photovoltaic (PV) systems integrated with low voltage (LV) grids has led to a great need to analyse the impact of these systems on the quality of electricity and the reliability of its supply. This paper presents and compares the energy quality requirements imposed by various countries on photovoltaic plants. Then, based on real object tests and simulation in DIgSILENT PowerFactory, the impact has been identified of insolation on the generation output, range of harmonic emissions, changes in voltage levels, and total harmonic distortion (THD) in current and voltage. The results depended on the micro-source power and location, and the grid load.
PL
Wzrost liczby systemów fotowoltaicznych (PV) zintegrowanych z sieciami niskiego napięcia (nn) spowodował ogromną potrzebę analizy wpływu tych systemów na jakość energii elektrycznej i niezawodność jej dostaw. W artykule przedstawiono i porównano wymogi jakości energii, jakie różne kraje nakładają na instalacje fotowoltaiczne. Następnie na podstawie przeprowadzonych badań na rzeczywistym obiekcie i symulacji w programie DIgSILENT PowerFactory określono m.in. wpływ nasłonecznienia na generację, zasięg emisji harmonicznych, zmiany poziomów napięcia, współczynnik całkowitej zawartości harmonicznych (THD) w prądzie i napięciu. Wyniki uzależniono od mocy mikroźródła, jego umiejscowienia oraz od obciążenia sieci.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.