Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 8

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  electrical impedance
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
The article presents the concept of using VNA (Vector Network Analyzer) to measure the temperature of the MOS transistor junction. The method assumes that the scattering parameters of the network consisting of the transistor depend on the temperature. The tests confirmed the influence of temperature on the S11 parameter and the input network capacity during ambient temperature changes in the range of 35-70°C. Measurements were made for the gate-source (G-S) input of the system. The measurements were carried-out with the transistor in the ON/OFF states. In order to validate the measurements, the temperature of the tested element was recorded with the MWIR Cedip-Titanium thermal imaging camera.
PL
W artykule przedstawiono koncepcję wykorzystania wektorowego analizatora sieci VNA (ang. Vector Network Analyzer) do pomiaru temperatury złącza tranzystora MOS. Metoda zakłada, że parametry rozpraszania sieci elektrycznych wewnętrznych struktur tranzystora zależą od temperatury. Badania potwierdziły wpływ temperatury na parametr S11 oraz na pojemność wejściową przy zmianie wartości temperatury otoczenia w zakresie 35-70°C. Pomiary wykonano dla wejścia bramka-źródło (G-S) układu. Pomiary przeprowadzono z tranzystorem w stanach ON/OFF. W celu walidacji pomiarów, temperaturę badanego elementu rejestrowano kamerą termowizyjną MWIR Cedip-Titanium.
PL
Przedstawiono wyniki wstępnych prac doświadczalnych mających na celu wykrycie i różnicowanie obiektów zanurzonych w środowisku wodnym. Do detekcji wykorzystano pomiar impedancji elektrycznej w zakresie niskich częstotliwości. Wyniki pracy wskazują, że możliwe jest odróżnienie organizmów żywych (ryby) od przedmiotów martwych (kamienie, pęcherzyki) w sposób pewny. Metoda tego typu nie była dotąd stosowana a jej wyniki wskazują, że może być ona przydatna w sytuacji, gdy inne metody (hydroakustyczna, optyczna) nie są w stanie udzielić istotnych informacji o obiekcie zanurzonym.
EN
Results of preliminary experiments with the detection and recognition of objects submerged in water are presented. Measurements of the electrical impedance in low frequency range were used. Results of experiments confirmed that living organism like fish can be reliably recognized from other objects (stones, bubbles, etc.). The presented method was not applied for the detection of submerged objects up till now and seems to be interesting alternative, and can give reliable results when other methods (hydroacoustic, optical) are unable to give usable information.
3
Content available remote Układy do pomiaru impedancji elektrycznej w zastosowaniach biomedycznych
PL
Przedstawiony niżej tekst opisuje metody pomiarowe stosowane do pomiaru impedancji elektrycznej używane w zastosowaniach biomedycznych. Opisano również opracowany przez autora układ do cyfrowego pomiaru zespolonej impedancji elektrycznej.
EN
These articles describe principles of most often used methods of electrical impedance measurements for biomedical purposes. Modern digital device for complex impedance measurement, designed by author, also has been presented.
PL
Celem artykułu jest przedstawienie problemów, które stoją przed konstruktorami urządzeń do transmisji danych cyfrowych poprzez sieci energetyczne niskiego napięcia. W artykule zaprezentowano też prototypowe urządzenie realizujące taką transmisję i opisano zadania, jakie ma realizować jego oprogramowanie. Przeprowadzone testy pozwoliły wyciągnąć wnioski co do warunków, które muszą być spełnione, aby transmisja przebiegała poprawnie.
EN
The scope of the paper is the presentation of problems to be solved by constructors of devices for digital data transmission using a low voltage power line. The paper presents a prototype device built for this purpose and describes tasks for the software. Conclusions on the correct transmission conditions are drawn from the results of the conducted tests.
5
Content available remote Advances in electrical impedance methods in medical diagnostics
EN
The electrical impedance diagnostic methods and instrumentation developed at the Gdansk and Warsaw Universities of Technology are described. On the basis of knowledge of their features, several original approaches to the broad field of electrical impedance applications are discussed. Analysis of electrical field distribution after external excitation, including electrode impedance, is of primary importance for measurement accuracy and determining the properties of the structures tested. Firstly, the problem of electrical tissue properties is discussed. Particular cells are specified for in vitro and in vivo measurements and for impedance spectrometry. Of especial importance are the findings concerning the electrical properties of breast cancer, muscle anisotropy and the properties of heart tissue and flowing blood. The applications are both important and wide-ranging but, for the present, special attention has been focused on the evaluation of cardiosurgical interventions. Secondly, methods of instrument construction are presented which use an electrical change in conductance, such as impedance pletysmography and cardiography, for the examination of total systemic blood flow. A new method for the study of right pulmonary artery bloodftow is also introduced. The basic applications cover examination of the mechanical activity of the heart and evaluation of many haemodynamic parameters related to this. Understanding the features that occur during blood flow is of major importance for the proper interpretation of measurement data. Thirdly, the development of electrical impedance tomography (ElT) is traced for the purposes of determining the internal structure of organs within the broad field of 2-D and 3-D analysis and including modelling of the organs being tested, the development of reconstruction algorithms and the construction of hardware.
6
Content available remote Analysis of non-linear properties of cardiomyocyte cellular membranes
EN
Non-linear properties of cardiomyocyte membranes are poorly understood. We model a cell membrane using the Beeler-Reuter model with the Drouhard-Roberge modification (the BRDR model). Simulations are performed using AC voltage test excitation of 1 or 100kHz frequency and 1 or 10mV RMS. Values of currents flowing through the cell membrane are considered to be the response. The BRDR response is presented at the fundamental frequency and at its second and third harmonics. The response is mainly contributed to by the time-independent potassium current (iK1) during resting membrane potential. The level of currents varies strongly during the period of action potential. However, the linear response from the membrane capacitance is relatively high. The second and third harmonics of the 1kHz/10mV probing voltage carry some information about the action potential. In particular, it may be used to investigate the process of repolarization and its disorders.
PL
W pracy oceniono przydatność zastosowania techniki pomiaru zmian impedancji elektrycznej środowiska hodowlanego dla prognozowania mikrobiologicznego aktywności metabolicznej mieszanej kultury bakterii z rodzaju Bacillus, podczas procesu biodegradacji ścieków przemysłu ziemniaczanego. Dynamikę zmian impedancji elektrycznej opisano matematycznym modelem Gompertza oraz parametrami modelu (maksymalną szybkością zmian impedancji Imax oraz czasem jej osiągnięcia XI), które następnie porównano z chemiczną oceną zdolności mikroorganizmów do biodegradacji oczyszczanych ścieków, wyrażoną wielkością redukcji chemicznego zapotrzebowania tlenu (ChZT).
EN
The usefulness of electrical impedance changes analysis during biodegradation of potato industry wastewaters for microbiological prediction of Bacillus mixed culture metabolic activity was estimated. The dynamic of electrical impedance changes was described by Gompertz mathematical model and its two parameters: maximal impedance changes rate (Imax) and the duration of time in which the Imax) is achieved (XI). The parameters were compared with the ability of microorganisms for wastewater biodegradation, expressed as COD reduction.
PL
Istotą problemu jest wykorzystanie elektrycznej impedancji zbrojenia do jego nagrzewania w celu polepszenia warunków zwilżania. Celem jest udoskonalenie technik wprowadzania dyspersyjnych komponentów zbrojących. Optymalizacja temperatur powierzchni kontaktu powinna zmniejszyć wielkość niezbędnych naprężeń ścinających, występujących w ciekłym metalu podczas mechanicznego mieszania komponentów. Pozwoli to na skrócenie czasu mieszania i zmniejszenie jego intensywności. Wśród technologii stosowanych w wytwarzaniu kompozytów dyspersyjnych szerokie zastosowanie posiadają techniki wykorzystujące powierzchniową, fizykochemiczną aktywacje zbrojenia. Proponowana technologia służy inicjowaniu i intensyfikowaniu zjawisk powierzchniowych - dokładnie w centrum zachodzących procesów. Technologia może stanowić uzupełnienie przemysłowej techniki pneumatycznego wprowadzania cząstek zbrojących, których wykorzystanie jest szczególnie uzasadnione dla kształtowych odlewów kompozytowych. Do tej pory jednym z głównych elementów procesu wprowadzania cząstek było ich nagrzewanie w lancy. Nagrzewanie następowało w sposób pośredni od ścian lancy z jednoczesnym nagrzewaniem gazu nośnego. Według prezentowanej technologii, nagrzewanie zbrojenia powinno następować przez wykorzystanie ciepła Joule'a-Lenza z uwzględnieniem elektrycznych cech zbrojenia. W opracowaniu porównano metody nagrzewania indukcyjnego i bezpośredniego tzw. „naboju zbrojenia", będącego walcową próbką o stałej objętości, poddaną działaniu prądu elektrycznego.
EN
The essential ot problem is using electrical impedance of reinforcement to heating it in order to improve wetting conditions. The aim is improvement of technique injection of dispersion reinforcement component. The optimization of contact surface temperatures should to decrease value of indispensable shearing stresses, which occurs in liquid metal during mechanical mixing of components. This permits to shorten mixing time and to decrease it intensity. Among technologies using to producing dispersion composites the wide application heaving techniques which use physical and chemical surface activation of reinforcement. The proposed technology permits to initiate and intensify surface phenomena exactly in center of proceeding processes. Technology may present completion of industrial technique pneumatic injection of reinforcement particles, which using is especially justified for form composites casting. Until now one of general elements of particles injection process was a heating its in lance. The heating followed in indirect way from lance wall with heating carrier gas. According to presented technology the heating of reinforcement should follow by using Joule-Lenz heat with taking into account electrical characteristic of reinforcement. In work was compared an induction heating method and direct heating so-called ..reinforcement cartridge" which is expose a cylindrical specimen with constant volume to electrical power action. Figure 1 shows requirements parameters process of heating and resistance method of reinforcement activation.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.