Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 10

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  electric safety
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
The aim of the considerations presented in the article was a stand-alone groundbased photovoltaic power plant. The article is devoted to the qualitative analysis of some lightning protection configurations. These types of constructions often require an individual look at the design and execution of lightning protection installations, which causes problems with the selection of optimal solutions. These problems relate primarily to the way the lightning rods are arranged to create protection zones, but also to the way they are attached: to the supporting structure for PV modules or as free-standing. Another problem raised in the article is the way how lightning current is discharged from rods to the ground and how it is dispersed there. Due to the vast area of such facilities and the requirements for electrical safety, it is necessary to consider and design a ground system with optimal electrical parameters, but also technical and economic ones. All these elements have their impact on the value of voltages induced in the electrical installation, which is also presented in the content of the article as the magnetic field distribution and calculation of induced voltages in an exemplary configuration. Finally, this article will compare described technical solutions encountered in selecting the best protection method for this type of photovoltaic installation.
PL
W artykule przedstawiono najistotniejsze problemy związane z ustanawianiem służebności przesyłu na terenach, przez które przebiegają funkcjonujące od wielu lat linie napowietrzne o różnym poziomie napięcia. Wskazując na obszar, na którym należy rozważyć ustanowienie służebności przesyłu, przeanalizowano możliwości wykonywania różnego rodzaju zabiegów eksploatacyjnych, w tym związanych z koniecznością usunięcia awarii linii.
EN
Articles presents most important issues associated with establishment of transmission easment along long operationg power lines of varying voltage levels. It nominates areas designated for transmission easment and analyses different options for line maintenance including line breakdown.
PL
Stworzenie warunków zapewniających poprawne i bezawaryjne działanie nowoczesnych i coraz bardziej rozbudowanych systemów elektrycznych i elektronicznych wymaga zastosowania rozwiązań chroniących te systemy przed oddziaływaniem piorunowego impulsu elektromagnetycznego.
PL
Kontynuujemy analizę niezawodności urządzeń stacyjnych SN, które nie biorą bezpośredniego udziału w przetwarzaniu oraz przesyłaniu energii elektrycznej. Są one jednak elementem niezbędnym do prawidłowego funkcjonowania sieci i stacji średniego napięcia. W tej części więcej uwagi poświęcimy przekładnikom prądowym oraz układom elektroenergetycznej automatyki zabezpieczeniowej i sterowniczej (EAZiS). Uszkodzenia tych urządzeń wpływają na awaryjność sieci, w których są zainstalowane.
PL
Pierwsza część artykułu omawia znaczenie norm w Unii Europejskiej oraz oznaczenia norm dotyczących elektroenergetycznych sieci rozdzielczych i instalacji. Następnie omawia zakres i wybrane postanowienia normy PN-EN 61140, tj. zasady ochrony przed porażeniem elektrycznym, prądy dotykowe, prądy przewodu ochronnego PE w instalacjach i urządzeniach niskiego napięcia i inne wymagania tej normy. Następnie są omówione nowe zasady i wymagania stawiane ochronie przeciwporażeniowej w normie PH-HD 60364-4-41 tj. zakres tematyczny tej normy, wymagania podstawowe, wymagania wspólne dla układów TN i TT stawiane środkowi (systemowi) ochrony - samoczynne wytaczanie zasilania. Omówiono też dobór i montaż wyposażenia elektrycznego instalacji niskiego napięcia w normie PN-HD 60364-5-51, tj. zakres tematyczny tej normy i sposoby oznaczania barwami przewodów PEN i żył przewodów wielożyłowych oraz schematy, tablice i wykresy.
EN
The first part of the article discusses the importance of standards in the European Union and designations of standards concerning the power engineering installations and distribution networks. Then it discusses the range and selected provisions of standard PN-EN 61140 i.e. principles of electric shock protection, touch currents, rotective conductor currents PE in installations and devices of low voltage and other requirements of that standard. Then the new principles and requirements concerning the shock protection in standard PH-HD 60364-4-41are presented i.e. the thematic range of that standard, the basic requirements, the common requirements for systems TN and TT concerning the device (or the system) of protection - automatic switch off the supply. The selection and montage of electric equipment of low voltage installations in accordance with the standard HD 60364-5-51 was also discussed i.e. the thematic range of that standard and the methods of marking with colours the conductors PEN and cable conductors in many-core cables and schemes, tables and diagrams.
PL
Przedstawiono ogólną ocenę stanu istniejącego i dylematy rozwoju krajowej elektroenergetyki w okresie do 2030 roku. Zwięźle opisano wybrane problemy wyboru technologii ze szczególnym uwzględnieniem gazowych technologii wytwarzania energii i ich wpływu na usługi regulacyjne.
EN
The general problems of present stage and dilemmas of Polish power sector development up to 2030 are presented. The problems regarding the technology choice due to gas fueled power plants are shortly described. The influence of gas fueled power plants regarding ancillary services for power system are presented.
PL
W Polsce budowanych jest coraz więcej samoobsługowych stacji benzynowych. Konsekwencją braku stałej obsługi ludzkiej na takich stacjach są zwiększone wymagania bezpieczeństwa jej obsługi przez klientów, w tym również kwestia odpowiednich zabezpieczeń elektrycznych.
PL
Artykuł przedstawia analizę działania powszechnie stosowanych wyłączników różnicowoprądowych o wyzwalaniu niezależnym od napięcia sieci przy znamionowej i podwyższonej częstotliwości prądu różnicowego. Zaprezentowano konstrukcje obecnie stosowanych wyłączników i charakterystyki ich działania w warunkach określonych przez odpowiednie normy przedmiotowe oraz w warunkach odbiegających od znormalizowanych, a które mogą pojawić się na przykład w obwodach z przemiennikami częstotliwości. Z analizy wynika, że podwyższenie częstotliwości obniża czułość zabezpieczenia, a w niektórych przypadkach zabezpieczenie w ogóle nie reaguje na prąd różnicowy. Znajomość rzeczywistych charakterystyk działania stosowanych powszechnie wyłączników różnicowoprądowych, przy różnych częstotliwościach prądu różnicowego ma duże znaczenie dla bezpieczeństwa użytkowania urządzeń elektrycznych niskiego napięcia.
EN
The paper presents an analysis of the commonly used voltage independent residual current circuit breakers (RCCBs) for rated and higher frequency of residual current. Typical construction and operation characteristics in normal and specific conditions which may occur in circuits with frequency converters are described. This analysis indicates that earth fault current frequency exceeding rated value often causes improper operation of residual current devices. In some cases the protective device may not trip at all. For effectiveness of protection against electric shock in low voltage networks it is important to know the true residual current device tripping current versus frequency.
PL
Omówiono poziom izolacji jako czynnik decydujący o prawidłowej pracy sieci zasilania gwarantowanego. Przedstawiono metody monitoringu stanu izolacji oraz stosowane urządzenia.
EN
Insulation level is described as the decisive factor of correct operation of guaranteed supply. Monitoring methods and equipment used are presented.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.