EN
Increasing the presence of non-conventional clean energy sources in Electrical Power Systems (EPS) is a global strategic goal. Particularly, photovoltaic systems are attractive due to their versatility, low maintenance cost, easy installation, noiselessness, etc. However, the integration of photovoltaic systems into EPS increases the necessary regulation actions performed by system generators due to stochastic fluctuations of solar radiation, especially on cloudy days. Even using complex models that consider many variables, solar irradiation and its corresponding photovoltaic power generation are difficult variables to forecast with accuracy in cloudy day scenarios. To address this problem, Energy Storage Systems (BESS) have been proposed as a solution to mitigate the variability of photovoltaic generation, which reduce the need to use traditional spinning reserves and provide auxiliary grid services. The BESS selection required to mitigate photovoltaic generation is directly related to the worst-case daily variability of photovoltaic generation in the short term. This paper proposes a practical estimation of daily perspective photo voltage solar generation curve in Electrical Power Systems.
EN
The paper presents issues related to the implementation of back-up short-circuit protection in the final sections of an underground medium voltage distribution network. The difficulties may arise from regulatory requirements regarding the operation time of protection devices in potentially explosive areas and relatively low values of short-circuit currents compared with load currents. Sample calculations results have been presented to illustrate the problems of selecting current settings of short-circuit protection. A method to overcome these problems by using transformer stations with a circuit breaker on the primary side has been shown.
PL
W artykule przedstawiono trudności związane z z rezerwowaniem zabezpieczeń przed skutkami zwarć międzyfazowych w końcowych odcinkach dołowych sieci średniego napięcia. Trudności te mogą wynikać z wymagań normatywnych dotyczących czasu działania zabezpieczeń w pomieszczeniach zagrożonych wybuchem oraz stosunkowo niewielkich wartości prądów zwarciowych w porównaniu z prądami roboczymi. Zaprezentowano przykładowe wyniki obliczeń ilustrujące problemy doboru nastaw zabezpieczeń zwarciowych oraz przedstawiono sposób wyeliminowania tych problemów przez zastosowanie stacji transformatorowych z wyłącznikiem po stronie GN.
PL
Poruszane w artykule zagadnienia techniczne systemu elektroenergetycznego dotyczą warunków, parametrów i zachowań pracy systemu elektroenergetycznego w stanach ustalonych i nieustalonych. Wśród prezentowanych metod i narzędzi analitycznych poruszane są również bieżące zagadnienia oddziaływania nowych technologii, począwszy od układów przesyłowych, dystrybucyjnych, a skończywszy na technologiach rozproszonych i źródłach odnawialnych. Rozważane problemy skupiają się wokół interakcji pomiędzy systemem elektroenergetycznym a podsystemami i urządzeniami, a także przypadkami narażeń na oddziaływania zewnętrzne. Problemy te są często wspólne dla operatorów systemów, nie tylko w Europie, ale również w państwach pozaeuropejskich. Ciągły rozwój urządzeń, instalacji i technologii wytwórczych wyznacza nowe potrzeby i wyzwania dla przyszłych struktur systemów elektroenergetycznych. Prezentowane treści są więc wyznacznikami przyszłych kierunków badań.
EN
Technical issues mentioned in this article and concerning power systems refer to conditions, parameters and behaviors of a power system work in transient and steady states. Among the presented methods and analytic tools there are also some current topics on the impact of new technologies on various aspects of the power industry, from transmission and distribution systems to distributed technologies and renewable sources. The considered problems focus on interactions between a power system and its subsystems and appliances as well as on cases of exposure to external influences. These problems are often the common ones for system operators not only in Europe but also in other countries. The continuous development of equipment, installations and production technologies defines new requirements and challenges for the future power system structures so one could say that the presented content is the trendsetter for the future research directions.
PL
Artykuł dotyczy badania zmian parametrów pracy systemu elektroenergetycznego w warunkach narastania jego obciążenia. Wyniki tych i podobnych badań mogą prowadzić do rozszerzenia aktualnych poglądów na temat sztywności sieci, jej stabilności i warunków postawania kołysań mocy w systemie. Kołysania mocy często stanowią początek rozległych awarii systemowych.
EN
Presented is here the research on changes of a power system working parameters in conditions of the growing power flow. The results of these and similar examinations can lead to broadening of actual ideas concerning network stiffness, its stability and conditions in which the power swing in a system emerges. Power swings become often the beginning of major system breakdowns.
5
Content available remote Tajemnicze ograniczniki przepięć typów B + C lub B + C + D
PL
Przeznaczeniem urządzeń do ograniczania przepięć SPD (ang. Surge Protective Device) jest ochrona instalacji i urządzeń przed działaniem przepięć atmosferycznych indukowanych, przepięć wewnętrznych oraz przed bezpośrednim oddziaływaniem cząstkowego prądu piorunowego. Od kilku lat projektanci i wykonawcy instalacji elektrycznych napotykają w katalogach firm ograniczniki typów B+C B+C+D lub klas I+II, I+II+III. Początkowo stosowanie takich wyrobów i oznaczeń, można było uzasadnić wymogami norm niemieckich i brakiem norm krajowych. Obecnie jest to sprzeczne z ustaleniami norm, a stosowanie takich oznaczeń może być świadomie lub nieświadomie wykorzystywane do tworzenia mitu ograniczników, które są w stanie zapewnić ochronę tworzoną dotychczas przez wielostopniowe systemy SPD. W artykule przedstawiono podstawowe informacje dotyczące właściwości ochronnych SPD, zasad ich doboru i stosowania.
EN
The purpose of SPD (Surge Protective Device) is to protect electric power systems and equipment against lightning induced surges, switching surges in power system and direct influence of lightning current. For several years, designers and installers have been offered in cataloques SPD types B + C, B + C + D, or class I + II, I + II + III. Initially the use of these products and symbols can be justified requirements of German standards and absence of national standards. Currently it is not in compliance with the standards. This article presents the basic information on the overvoltage protective properties of the SPD, their tasks, places of installation and the required range of research.
EN
In this paper it is proposed a technique to identify the relevant neighbouring electric power systems using the Horizontal Network scheme. The developed methodology was applied to study the IEEE 118 test power network and the Iberian systems. All simulations were performed using the computational software package PSSŽE developed by the Siemens/PTI. From the simulation results, some conclusions that provide a valuable contribution to the understanding of the impact of the cross-border interconnections between the countries will be pointed out.
PL
W niniejszej pracy zaproponowano technikę w celu określenia sąsiadujących systemów elektroenergetycznych przy realizacji programu Network. Opracowana metodyka została zastosowana do testu IEEE 118 sieci energetycznej i systemów Iberyjskiego. Wszystkie symulacje zostały przeprowadzone przy użyciu pakietu oprogramowania obliczeniowego PSSŽE opracowany przez Siemens/PTI.
PL
W artykule rozpatrzono dwa problemy badawcze. Pierwszy odnosi się do modelowania elementów i układów energoelektronicznych stosowanych w układach elektroenergetycznych oraz optymalnego doboru parametrów i opcji sterowania załączaniem zaworów. Drugi rozpatrywany problem to optymalizacja struktury sieci, w której zastosowano elementy i układy energoelektroniczne oraz rozproszone źródła energii. Dla każdego przypadku zaproponowano zastosowanie odpowiedniej metody obliczeniowej.
EN
Two investigation problems will be discussed in the paper. The first one relates to the modeling of the power electronics system elements as well as optimal parameters and control options for electronic valves switching The second discussed problem relates to the optimization of the power network structure including power electronics elements and systems as well as distributed energy sources. For each case an appropriate calculation method has been proposed.
EN
The paper shows the new hierarchical approach to the management of the complex power systems. The solution presents new methods of state space estimation and optimization of the model of the power system at the incompleteness or low accuracy of the arriving information. The exchange of energy between parts of the system is treated as the problem of parameter veracity. The method unifies the mathematical models of subsystems of lower levels into more reliable and accurate final dispatcher system.
PL
Praca dotyczy problemów związanych z konstrukcją programu sterującego przepływem mocy w złożonych systemach elektroenergetycznych. Zaprezentowano nowe podejście hierarchiczne, przedstawiając metodę estymacji zmiennych stanu i optymalizacji trybów pracy poszczególnych części systemu w warunkach niekompletności lub małej dokładności informacji wejściowej. Zaproponowana procedura podejścia scala modele obwodowe stworzone dla podsystemów niższego poziomu, pozwalając na uzyskanie większej dokładności i pewności działania systemu.
EN
In the paper, the OZZEE software developed by the authors to compute the unreliability indicators of the electrical energy delivery to the customers and to support the reliability analysis of electric power systems is described. Basing on a given reliability structure and on the integrated elements parameters, the program can found the mean annual downtime, mean annual failure rate as well as the power supply unreliability coefficient. In analysis of the complex structures, the computation model based on the mean failure cuts (MFC) method has been applied. The assumptions applied when constructing the algorithm of computations as well as examples of the program applications in analysis of the complex grid systems have been presented.
PL
Omówiono wyniki prac Komitetu Studiów C1 CIGRE dotyczące planowania rozwoju systemów elektroenergetycznych w warunkach niepewności związanych z prognozowaniem zapotrzebowania na energię, lokalizacją nowych źródeł wytwarzania energii elektrycznej oraz modernizacją istniejących, a także skutkami restrukturyzacji energetyki w warunkach rynkowych. Stwierdzono konieczność wprowadzenia nowych metod prognozowania.
EN
Discussed are results of the C1 Study Committee CIGRE works referring to electric power systems development planning in uncertainty conditions relating to prognosing the demand for energy, localization of new electric energy production sources and modernization of the already existing ones, as well as to the results of power industry conversion in market conditions. Ascertained is the necessity to introduce new prognosing methods.
PL
Przedstawiono rozwój systemu przesyłowego i uzasadnienie inwestowania w system przesyłowy, metody projektowe służące zapewnieniu odporności systemów energetycznych na awarie, w tym narzędzia umożliwiające efektywne planowanie, a także wystarczalność i bezpieczeństwo wytwarzania i przesyłu energii w kontekście przyszłej struktury i lokalizacji wytwarzania.
EN
Presented is development of transmission systems and justification of investing in them, designing methods serving to ensure failure resistance of electric power systems including tools enabling effective planning. Discussed is also sufficiency and safety of energy generation and transmission in the context of future structure and location of generation places.
PL
Najbardziej znaną charakterystyką generatora synchronicznego jako źródła mocy w SEE jest charakterystyka Q(P) określająca obszar pracy generatora synchronicznego. Dla takiej charakterystyki parametrem jest napięcie na szynach stacji na którą dany generator pracuje. Dla lepszego zobrazowania wpływu napięcia na zdolności wytwórcze mocy biernej można posłużyć się mało znaną w praktyce charakterystyką U(Q) określającą jak zmienia się moc bierna generatora przy zmianach napięcia na szynach stacji w wyniku oddziaływania pozostałej części SEE. Dla takiej charakterystyki parametrem jest moc czynna. W referacie wyprowadzono wzory na charakterystykę U(Q) i zwrócono uwagę na fakt bardzo silnej zależności mocy biernej generatora w stanach znacznego obniżenia się napięć w SEE. Ma to znaczenie dla interpretowania zjawisk przy awariach systemowych o charakterze napięciowym.
EN
The most widely known characteristic of a synchronous generator is the power capability curve Q(P) that describes the area of operation of the synchronous generator. The power capability curve uses the substation terminal voltage as a parameter. A better illustration of the influence of voltage on the capability of a generator as the source of reactive power is a less known U(Q) characteristic that illustrates how the generated reactive power changes as the terminal voltage changes due to the influence of the rest of the system. The U(Q) characteristic uses real power as a parameter. In this paper equations for the reactive power capability curve U(Q) have been derived emphasising a strong dependence of the generated reactive power on the voltage when the voltage is strongly depressed. The latter is especially important when interpreting phenomena accompanying voltage-related system disturbances.
PL
Prowadzone prace badawczo-rozwojowe doprowadziły do opracowania i zastosowania wielu technologii i urządzeń pozwalających wykorzystywać metan jako paliwo w specjalnych instalacjach ciepłowniczo-energetycznych. Z polskich kopalń węgla kamiennego duże ilości metanu w powietrzu wentylacyjnym są odprowadzane do atmosfery, dlatego potrzebne jest pilne podjęcie prac analitycznych, projektowych i przedsięwzięć inwestycyjnych umożliwiających utylizację metanu.
EN
The methane accompanying the mining extraction of coal as the basic mineral and not recovered by a methane drainage system is released, in its greater part, into the ventilation air and mixes with it, thus producing a methane-air mix with different methane concentration level. For economic and ecologic reasons the utilization of methane from coal seams is very important. However, the utilization and economic applications of the mine air methane presents a great problem not only in the Polish coal mining but in the world coal mining in general. The research and development works conducted have lead to developing and implementing a number of technological procedures and designs of equipment enabling the usage of methane as a fuel for special thermal and electric power systems.
PL
Przedstawiono koncepcję wyznaczania impedancji systemu elektroenergetycznego w warunkach ruchowych.
EN
An idea of evoluation of electric power system short-circuit impedance in operational conditions.
PL
Przedstawiono koncepcję tworzenia ogólnokrajowej sieci wybiórczego odciążania awaryjnego systemu elektroenergetycznego.
EN
The paper presents an idea of country-wide network for selective unloading of electric power system in the case of failure.
PL
Przedstawiono nowoczesny system zbierania, archiwizacji i wizualizacji przebiegów, opracowany i oferowany przez Energotest-Energopomiar. Omówiono zagadnienia pojawiające się z chwilą obróbki i prezentacji na wspólnym wykresie czasowym przebiegów z różnych rejestratorów, mechanizmy do filtracji przebiegów z wybranego obiektu, dostępne funkcje, możliwości zastosowania w systemie rozproszonym.
EN
Presented is modern acquisition and recording system of transients and presenting them in visual form elaborated and offered by Energotest-Energopomiar. Discussed are problems occurring at treatment and presentation of the transients achieved from various recorders on common time curve, filtration mechanisms of transients from chosen object, accessible functions and possibilities of use in dispersed system.
EN
Electric market dynamics is important for market administrators to maintain market reliability, forecast problems and take remedy actions. Equilibrium analysis models have been built in the past to find market equilibrium. However, to achieve the goal of deregulation, not only should market equilibrium be identified, but also achievability of equilibrium and market transition process to equilibrium should be known. These properties cannot be got without studying interactions between market participants, which were not included in equilibrium analysis. Interactions between Generation Companies (GENCOs) are major source of market dynamics. They are particularly important for electric market and GENCOs decision making because there are few participants in electric market and current electric markets are oligopolistic. This paper models GENCOs decision making and interactions between different GENCOs from a control point of view. GENCO decisions that are evolving with time are modeled as control processes and electric markets are modeled as control systems. Corresponding market dynamics and properties are studied. An oligopolistic market is used to illustrate the ideas and numerical examples are provided for all cases. Results showed new models can provide conclusions that are difficult or impossible to get by pure equilibrium analysis.
PL
Przedstawiono koncepcję sterowania predyktywnego w zastosowaniu do automatycznej regulacji mocy czynnej częstotliwości (ARCM) dla potrzeb regulacji wtórnej jako nietypowy przypadek metodologii sterowania predyktywnego wg modelu (MPCI. Przypadek ten opiera się na predykcji silnie krótkoterminowej sygnałów regulacyjnych: wejścia i wyjścia regulatora centralnego (konwencjonalnego) jako modele autoregresji z integratorem (ARp. Zaproponowana koncepcja kontrolera predyktywnego usprawni działanie centralnego regulatora ARCM. Jego działanie zweryfikowano pod względem efektywności za pomocą metod symulacyjnych z wykorzystaniem modelu inkrementalnego.
EN
A conception of the predictive control in application to load - frequency control in an electric power system as an untypical case of the model based on the methodology of predictive control (MPC) is presented in the paper. This model is based on very short prediction modelling of the control signals being input and output of the central (conventional) regulator with models as auto-regressive ones with the integrator (ARII. Proposed concept improves the regulator action. The efficiency of its action is verified with the use of the power system incremental model in the simulation procedure.
PL
Przedstawiono niektóre opinie o jakości północnoamerykańskiego systemu elektroenergetycznego, zarys metodyki badania awarii oraz jej przebieg. Krótko rozważono czy krajowy system elektroenergetyczny jest narażony na podobny rodzaj awarii.
EN
Some opinions concerning the quality of the North American electric power system are presented, as well as the outline of the failure research methodology and the failure description. It is briefly analyzed whether the domestic electric power system is endangered by similar types of power failures.
PL
Opisano kolejność pojawiania się awarii energetycznych w USA dnia 14 sierpnia br. W odniesieniu do polskiego systemu przesyłowego stwierdzono m.in., że jest on rozwinięty słabo, a jego połączenia z systemem 110 kV powodują szereg problemów technicznych, ekonomicznych i własnościowych. Obserwuje się znaczne przepływy kołowe. Ceny rynkowe energii nie skłaniają do inwestycji w nowe moce wytwórcze, a w strategii rozwoju elektroenergetyki brakuje mechanizmów stymulujących takie inwestycje.
EN
A sequence of power failures in the USA, on the 14th August 2003, is described. With reference to the Polish national grid it is stated among other things that it is poorly developed and its connections with the 110 kV system cause various technical, economic and ownership problems. Considerable circular flows are noticeable. Market energy prices do not encourage investment in new power capacity, and the development strategy for electric power engineering does not include mechanisms which stimulate such investment.
first rewind previous Strona / 2 next fast forward last