Ograniczanie wyników
Czasopisma help
Autorzy help
Lata help
Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 108

Liczba wyników na stronie
first rewind previous Strona / 6 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  electric power
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 6 next fast forward last
1
Content available remote Is photovoltaic capable to replace heat power plants in the future?
EN
A sudden gain of power installed in Polish photovoltaics during the recent years has been undoubtedly a great surprise for all. From the marginal position few years ago photovoltaics has become the unquestionable leader in respect of the installed power value from among the different types of renewable electric energy sources. It is anticipated that in the current year, the total value of power installed in Polish photovoltaic system will exceed value of 15 GW, leaving far behind – in this respect - wind energetics, even not mentioning other renewable sources of electric energy. Obtaining such high results was mainly possible owing to the state subsidies, developed governmental programs but also to a common enthusiasm which was the share of broad masses of our society – possessing of own power plant on the roof of one’s house became, at a certain moment, something fashionable and also, something which the majority of the owners of single family houses wanted to possess (at least to impress the neighbours). A specific euphoria which appeared in connection with the photovoltaics causes that there are announced extremely ambitious plans for its further development and the anticipated future values of the power installed in the photovoltaic panels make you feel dizzy. During the mentioned discussions, we forget that the heat power plants in Poland still constitute the basis of functioning of electric energy system. They produce still more than ca. ¾ of electric energy, produced in our country. Meanwhile, we may often and often meet the publicly announced opinion that heat power plants are no longer necessary because in the nearest future, the decided majority of the electric energy consumed in the country will come only and exclusively from renewable sources; the supreme role will be, of course, played by photovoltaics. Indeed, according to the respective decisions, which were once undertaken by the governmental authorities, most of the Polish coal-fired power plants will cease completely their activity as soon as during the nearest several years. The authors of the present paper undertake the attempt to answer the question: whether photovoltaics will be able to replace, in the future, Polish heat power plants, intended for liquidation. The answer to such question is univocally negative and not only due to the seasonality of electric energy production in photovoltaic installations but, first of all, due to the impossibility to introduce a very high power (order of tens of gigawatts) to electric network at the peak moment of its generation in photovoltaic installations. The necessary balancing of such high levels of power in the national electro-energetic system is also impossible. The authors try also to give the answer to the question: where we are now in respect of the degree of advancement of investments in photovoltaics and in connection with it, how much electric power may be additionally installed in Polish photovoltaic power plants. The next problem, undertaken by the authors is the attempt to estimate what percentage of the national demand on electric energy may be covered from photovoltaic installations, with the simultaneous economic justification.
PL
Gwałtowny przyrost w ostatnich latach mocy zainstalowanej w polskiej fotowoltaice był bez wątpienia dla wszystkich sporym zaskoczeniem. Z pozycji jeszcze kilka lat temu wyraźnie marginalnej fotowoltaika wysunęła się obecnie pod względem wartości mocy zainstalowanej na niekwestionowanego lidera spośród różnego rodzaju odnawialnych źródeł energii elektrycznej. Przewiduje się, że w bieżącym roku całkowita wartość mocy zainstalowanej w polskiej fotowoltaice przekroczy wartość 15 GW, daleko dystansując pod tym względem energetykę wiatrową, a o innych odnawialnych źródłach energii elektrycznej nawet nie wspominając. Uzyskanie tak wysokiego wyniku stało się możliwe głównie dzięki dotacjom państwowym, rozbudowanym programom rządowym, ale także poprzez zwykły entuzjazm, który udzielił się szerokim masom naszego społeczeństwa - posiadanie na dachu jednorodzinnego domku własnej elektrowni stało się w pewnym momencie po prostu czymś modnym, a także czymś, co większość właścicieli budynków jednorodzinnych chciałaby koniecznie posiadać, chociażby po to, aby zaimponować swoim sąsiadom. Swoista euforia, która zapanowała wokół fotowoltaiki powoduje, że powszechnie głoszone są niezwykle ambitne plany dalszego jej rozwoju, a przewidywane w przyszłości wartości mocy zainstalowanej w panelach fotowoltaicznych przyprawiają wręcz o zawrót głowy. Podczas tego rodzaju dyskusji zapomina się, że w Polsce elektrownie cieplne nadal stanowią podstawę funkcjonowania systemu elektroenergetycznego i to właśnie w nich wytwarzane jest nadal około trzech czwartych produkowanej w naszym kraju energii elektrycznej. Tymczasem coraz częściej można spotkać się z wygłaszanymi na forum publicznym opiniami, że elektrownie cieplne nie są nam już więcej potrzebne, ponieważ w najbliższej przyszłości zdecydowana większość konsumowanej w kraju energii elektrycznej pochodziła będzie tylko i wyłącznie ze źródeł odnawialnych, gdzie oczywiście nadrzędną rolę odgrywać będzie fotowoltaika. Istotnie, zgodnie z ustaleniami, która zapadły swego czasu na szczeblu rządowym zdecydowana większość polskich elektrowni cieplnych opalanych węglem kamiennym bądź brunatnym ma przestać całkowicie istnieć już w przeciągu najbliższych kilkunastu lat. Autorzy artykułu podejmują próbę udzielenia odpowiedzi na pytanie, czy fotowoltaika będzie mogła w przyszłości zastąpić przeznaczone do likwidacji polskie elektrownie cieplne. Odpowiedź na tak postawione pytanie jest jednoznacznie negatywna i to nie tylko z powodu sezonowości produkcji energii elektrycznej w instalacjach fotowoltaicznej, ale przed wszystkim z powodu niemożności wprowadzenia do sieci elektroenergetycznych mocy rzędu dziesiątek gigawatów w szczycie jej produkcji w instalacjach fotowoltaicznych oraz niewykonalności koniecznego zbilansowania tak wielkich poziomów mocy w krajowym systemie elektroenergetycznym. Autorzy usiłują także udzielić odpowiedzi na pytanie, w jakim miejscu pod względem stopnia zaawansowania inwestycji w fotowoltaikę obecnie się znajdujemy i w związku z tym, ile mocy elektrycznej można w polskich elektrowniach fotowoltaicznych jeszcze dodatkowo zainstalować. Kolejną kwestią poruszoną przez autorów, jest próba oszacowania, jaki procent krajowego zapotrzebowania na energię elektryczną można maksymalnie pokryć z instalacji fotowoltaicznych, aby tego rodzaju postępowanie było jeszcze w jakikolwiek sposób uzasadnione ekonomicznie.
EN
Solar energy is a unique source of renewable energy due to its availability and the unlimited quantity. It has long attracted the attention of scientists who are conducting theoretical and experimental research into its use. Solar energy plays an increasingly important role in the context of energy conservation. With the rising cost of conventional energy sources and limited access to natural resources, interest in the use of renewable energy sources is increasing. In this context, environmental protection is another factor favoring the development of technologies based on renewable energy sources. With economic development, the significance of new environmentally friendly technologies is increasing. One of the most popular ways for the average household to utilize renewable energy sources is by installing photovoltaic panels. Such an installation allows the use of solar energy to generate electricity, which contributes to reducing energy costs and protecting the environment. The article presents the results of an analysis of the exergy efficiency of prosumer photovoltaic systems found in the area of northern Poland. The analysis presented was based on actual operating parameters over a certain time interval. A key aspect is the analysis of exergy, which is not distributed in renewable energy sources (RES) systems.
EN
Vibration Energy Harvesting is being investigated for autonomous sensors and actuators that mainly utilize ambient and machine induced vibrations. Recently mechanical motion amplification is incorporated for improving power to weight ratio of vibration harvesters. The present study is motivated to investigate mechanical motion amplification characteristics with different configurations. The parameters investigated are motion amplification ratio, force transmissibility characteristics, weight of the electrical generator, effective damping coefficient achieved and linear nature of damping. Numerical analysis has been performed to compare important characteristics of device operating without amplification to that of with amplification with different configuration. The study has been concluded with comments on application of suitable type of amplification mechanism depending on weight/space constraints and desired effective damping coefficient.
4
Content available Autonomous constant voltage generator
EN
The relevance of this research work is due to the fact that farms and other farms are located at a considerable distance from sources of centralized power supply. Therefore, it is necessary to introduce autonomous generators as the main units that ensure the uninterrupted functioning of energy systems. The purpose of this research work is to analyze the features of the functioning of an autonomous constant voltage generator, as well as to determine the basic physical laws that are of fundamental importance in its operation. The basis of the methodological approach in this scientific study is a combination of methods of system analysis with an analytical study of the general principles of operation of such devices, which are of fundamental importance from the point of view of ensuring the proper level of operational reliability. The main results obtained in this research work should be considered the definition of equations for calculating the instantaneous values of the three-phase excitation current, as well as the peak value of the three-phase excitation current of an autonomous constant voltage generator. The results obtained in the course of this scientific research and the conclusions formulated on their basis are of fundamental importance for developers of modern technological systems, including autonomous constant voltage generators, as well as for employees of technological services of modern industrial enterprises, whose professional responsibility includes the practical operation of such devices to solve a complex of technical tasks facing these enterprises.
PL
Ważność niniejszej pracy badawczej wynika z faktu, że gospodarstwa rolne i inne gospodarstwa położone są w znacznej odległości od źródeł scentralizowanego zasilania. Dlatego konieczne jest wprowadzenie autonomicznych generatorów jako głównych jednostek zapewniających nieprzerwane funkcjonowanie systemów energetycznych. Celem niniejszego artykułu jest analiza cech funkcjonowania autonomicznego generatora napięcia stałego, a także określenie podstawowych praw fizycznych mających fundamentalne znaczenie w jego działaniu. Podstawą podejścia metodologicznego jest połączenie metod analizy systemu z opracowaniem analitycznym ogólnych zasad działania tego typu urządzeń, które mają fundamentalne znaczenie z punktu widzenia zapewnienia odpowiedniego poziomu niezawodności działania. Za główne wyniki uzyskane należy uznać określenie równań do obliczania wartości chwilowych prądu wzbudzenia trójfazowego, a także wartości szczytowej prądu wzbudzenia trójfazowego autonomicznego generatora napięcia stałego. Uzyskane w toku badań naukowych wyniki i sformułowane na ich podstawie wnioski są bardzo ważne dla twórców nowoczesnych systemów technologicznych, w tym autonomicznych generatorów stałego napięcia, a także dla pracowników służb technologicznych nowoczesnych przedsiębiorstw przemysłowych, których odpowiedzialność zawodowa obejmuje praktyczną obsługę takich urządzeń w celu rozwiązania kompleksu zadań technicznych stojących przed przedsiębiorstwami.
PL
W artykule przedstawiono dyskusję dotyczącą definicji mocy elektrycznej stosowanej w jednofazowych obwodach elektrycznych z prze- biegami niesinusoidalnymi zapisanymi w normie IEEE 1459-2010. Struktura artykułu przedstawia najpierw krytyczny komentarz dotyczący konkretnego zapisu normy, następnie podana jest propozycja zapisu, który zdaniem autora powinien się znaleźć w normie i w końcu pokazane są wyjaśnienia i dyskusja proponowanych zapisów. Jest to kontynuacja zagadnienia, które zapoczątkowano w [1].
EN
A discussion on the definitions of electric power used in single-phase electric circuits with nonsinusoidal waveforms stored in the IEEE Standard 1459-2010 is presented in the paper. The structure of the paper is such that firstly a critical comment is given relating to a specific record of the standard, then a proposition is given which, in the author’s opinion, should be included in the standard and finally clarification and discussion of the proposed notation. This is a continuation of the issue that started in [1].
EN
Energy harvesting shock absorbers can generate about 15-20 W of electric power for normal suspension velocities. However, higher weight, fail safe characteristics and space limitations have restricted development of regenerative shock absorbers to research prototypes. Power to weight ratio of regenerative shock absorbers can be improved by incorporating motion amplification. In the presented work, an innovative design of energy harvesting shock absorber has been presented that uses motion amplification for improving harvesting efficiency. Apart from improving electric power, the proposed solution is fail safe and can be easily incorporated in existing vehicles with only marginal change in suspension layout. Study includes detailed numerical analysis for vibration transmissibility to investigate comfort and safety. Further, a prototype has been fabricated and experimentation has been performed to compute electric power generated and comfort. Simulations have been performed on real size model with utilization of harvested electric power which indicates about 19% of overall harvesting efficiency.
PL
W artykule przedstawiono technologie stosowane w magazynowaniu energii oraz zastosowanie magazynów energii w aplikacjach sieciowych i poza siecią elektroenergetyczną. Szczególny nacisk położono na technologie wykorzystujące magazynowanie energii w postaci elektrycznej i ciepła.
EN
This article presents technologies used energy storage and the use of energy storage in on-grid and off-grid applications. The focus was mainly placed on technologies that use energy storage in the form of electricity and heat.
EN
The article presents a statistical analysis of electric power supplied to the friction node and temperatures of that node. The paper examines the dependence of the temperature lag of friction node of conformal contact on the amount of electric power consumption using the Pearson’s method. To the a/m analysis R software was applied [1‒3].
EN
The paper examines the dependence of the temperature of friction node of conformal contact on the amount of electric power consumption. It presents arguments confirming the validity of Kostetsky's energy hypothesis. R software was applied to the above-mentioned analysis.
EN
Thermoelectric generators using the Seebeck effect to generate electricity are increasingly used in various areas of human activity, especially in cases where a cheap high-temperature heat source is available. Despite many advantages, TEG generators have one major disadvantage: very low efficiency of heat conversion into electrical power which strongly depends on the applied load resistance. There is a maximum of generated power between the short and the open circuit in which it is zero. That is why optimization of TEG modules is particularly important. In this paper a method of maximization of generated power in a single TEG module is presented for two cases. The first case concerns a problem with fixed heat flux flow into the hot side of the module whereas the second one concerns a problem with fixed heat transfer parameters in hot heat exchanger i.e. supply gas temperature and heat transfer coefficient. A number of optimization results performed for various values of these parameters are presented and discussed.
PL
W artykule przedstawiono analizę mocy wytwarzanej przez blok energetyczny spalający biomasę. Wykonana analiza obejmuje okres eksploatacji jednostki wytwórczej wynoszący około 6 lat. Obliczenia wykonano na podstawie próby statystycznej obejmującej kilkaset tysięcy pięciominutowych przedziałów wytwarzanej mocy elektrycznej. Na podstawie zebranych danych empirycznych przeprowadzono analizę rozkładów statystycznych wytwarzanej mocy elektrycznej oraz wyznaczono rozkłady teoretyczne, których poprawność zweryfikowano testem zgodności λ Kołmogorowa.
EN
The article presents an analysis of the power generated by the biomass-burning power unit. The analysis covers the entire lifetime of the generating unit, which is approximately 6 years. The calculations were made on the basis of a statistical sample comprising several hundred thousand five-minute intervals of electric power output. Based on the collected empirical data, the statistical distributions of the generated electric power were analyzed and theoretical distributions were determined, the correctness of which was verified by Kolmogorov's λ compatibility test.
EN
This paper presents a statistical analysis of the variation of electric power consumption of a tribological station as a consequence of the process of wear of kinematic vapor of conformal contact working in the presence of a consumable of a defined content. It contains the presentation of test conditions and design of a test rig. Tribological tests were carried out at a room temperature for one velocity of relative motion. Determined was the influence of concentration of a selected consumable in SN-150 oil base on the variation of electric consumption of a tribotester. The statistical analysis was carried out on the basis of R software.
PL
W artykule przedstawiono analizę statystyczną zmiany poboru mocy elektrycznej stanowiska tribologicznego w wyniku procesu zużywania pary kinematycznej o styku konforemnym, pracującej w obecności preparatu eksploatacyjnego PE o zdefiniowanym składzie. Omówiono warunki badań oraz budowę stanowiska badawczego. Badania tribologiczne wykonano w temperaturze pokojowej dla jednej prędkości ruchu względnego. Określono wpływ stężenia wybranego PE w bazie olejowej SN-150 na zmianę poboru mocy elektrycznej tribotesteru dla wybranej prędkości ruchu względnego. Analizę statystyczną wykonano w oparciu o program R.
EN
An electric power steering system (EPS) is a new type of steering system developed after a mechanical hydraulic power system (MHPS) and electric-hydraulic power steering system (EHPS). In order to coordinate and solve the portability and sensitivity of the steering system optimally, taking an induction power steering system as the research object, the control algorithm of induction motor control under the EPS is studied in this paper. In order to eliminate the feed-forward performance degradation caused by the change of feed-forward parameters, an on-line identification algorithm of feed-forward parameters is proposed. It can improve the control performance of online identification among three feed-forward parameters in the T-axle motor, it improves on the robustness of feed-forward control performance, at the same time it also gives simulation and test results. This method can improve the control performance of the three feed-forward parameter online identification of the T-axis motor and improve the robustness of feed-forward control performance. At the same time, simulation and test results are given. The simulation results show that the algorithm can significantly improve the response speed and control accuracy of EPS system control.
PL
Produkcja energii elektrycznej na bazie źródeł odnawialnych systematycznie rośnie. Coraz częściej uważa się, że w długiej perspektywie zastąpią one tradycyjne źródła energii, jakimi są paliwa kopalne oraz energetyka jądrowa. Celem artykułu jest identyfikacja czynników technicznych i ekonomicznych warunkujących rozwój produkcji energii elek-trycznej na bazie źródeł odnawialnych. Zwrócono uwagę na zasoby surowcowe (konwencjonalne i odnawialne), wady i zalety odnawialnych źródeł energii elektrycznej oraz wpływ polityki energetycznej państwa na rozwój produkcji energii na bazie tych źródeł.
EN
Electricity production based on renewable energy sources is growing steadily. It is more and more of ten believed that in the long run they will replace traditional energy sources, which are fossil fuels and nuclear power. The purpose of this article is to identify technical and economic factors influencing the development of electricity production based on renewable energy sources. The attention was drawn to natural resources (conventional and renewable), the advantages and disadvantages of renewable energy sources and the impact of national energy policy on the development of energy production based on these sources.
15
Content available remote An experimental study of wind data of a wind farm in Kosovo
EN
In Kosovo, 97% of energy is generated from lignite-fired power plants. Apart from the energy generation, the combustion process emits around 8000 ktCO2/yr and 1.5 Mt of ash in the form of the fly and bottom ash. In Kosovo there is no MWh power generated from wind energy, i.e. this energy source is not utilized. Here, a proposed project for one location in Kosovo has been analysed in detail with the aim of installing the thirteen wind generators. The wind farm has successfully passed the testing period as foreseen by law. The wind farm is located near to Kamenica region. The wind measurements are carried out by the potential investor, wind speed at the installed site gives very promising wind data. In this issue, we have given different of power given in different highness of the wind turbine. After all, we conclude that based on the average wind speed from a wind turbine (60 m highness) we will have 1015.371kW which turns out to be satisfactory when it is multiplied by the number of turbines to be placed (thirteen) equal to 13,199 MWh, that will significantly reduce energy consumption from fossil fuels.
PL
Przedstawiono projekt farmy wiatrowej zlokalizowanej w Kosowie (w miejscowości Kamenica) wykorzystującej trzynaście generatorów. Analizowano wwpływ wysokości trubin wiatrowych – wybrano wysokość 60 m. Uzyskano moc rzędu 1015 kW. System trzynastu turbin generuje energię rzędu 13 MWh.
PL
W artykule przedstawiono dyskusję dotyczącą definicji mocy elektrycznej stosowanych w jednofazowych obwodach elektrycznych z przebiegami sinusoidalnymi zapisanych w normie IEEE 1459-2010. Struktura artykułu jest taka, że najpierw podany jest krytyczny komentarz odnoszący się do konkretnego zapisu normy, następnie podana jest propozycja zapisu, który zdaniem autora powinien się znaleźć w normie i w końcu wyjaśnienie i dyskusja proponowanych zapisów.
EN
A discussion on the definitions of electric power used in single-phase electric circuits with sinusoidal waveforms stored in the IEEE Standard 1459-2010 has been presented in the paper. The structure of the paper is such that firstly a critical comment is given relating to a specific record of the standard, then a proposition is given which, in the author's opinion, should be included in the standard and finally clarification and discussion of the proposed notation have been submitted.
PL
Artykuł dotyczy zastosowania programowania ewolucyjnego do optymalizacji niezawodności elektroenergetycznych sieci dystrybucyjnych. W artykule przedstawiono koncepcję i opis proponowanej metody oraz algorytm obliczeniowy. W końcowej części zaprezentowano przykładowe rezultaty obliczeń dla wybranej elektroenergetycznej sieci dystrybucyjnej.
EN
In the article is presented the evolutionary programming using the optimization of reliability the power distribution grids. The article presents the conception and description the evolutionary programming. The final part of the article describes sample calculations for power distribution grids using the developed method.
PL
Artykuł przedstawia zastosowanie hybrydowej metody ewolucyjnej do optymalizacji rozwoju sieci dystrybucyjnych energii. Zaproponowana metoda bazuje na algorytmie genetycznym współpracującym ze strategią ewolucyjną. W artykule zawarto koncepcję opracowanej metody oraz opis proponowanych algorytmów a także przedstawiono obliczenia opracowaną metodą dla wybranej elektroenergetycznej sieci dystrybucyjnej.
EN
The article represents to optimization of development of electric power nets the use of hybrid evolutionary method. Proposed method applies co-operation of genetic algorithms with evolutionary strategy algorithm. The article contains the results and description of calculations for chosen the electric power nets.
PL
W niniejszym artykule przedstawiono wyniki pomiarów parametrów określających jakość energii elektrycznej pobieranej przez nowoczesne urządzenia spawalnicze, spawające z wykorzystaniem metod: a) metoda MAG standard –stosując urządzenia transformatorowe i inwertorowe, b) metoda SpeedPulse - stosując urządzenia inwertorowe, dla dwóch stanów pracy. Dokonano również pomiarów energochłonności dla rozważanych metod.
EN
In this article we present the result of measuring the parameters defining the quality of electrical energy consumed by the modern welding equipment. The following welding methods were investigated: a) MAG standard method using transformer and inverter, b) SpeedPulse method using inverter, in two states of operation. Measurements of energy consumption for these methods were also conducted.
EN
Researched were the regularities in formation of the risk of occupational disease in staff caused by industrial-frequency electromagnetic field in extra-high voltage electric installations for further evaluation. Considered were the main conditions of electrical safety systems (optimum, permissible, harmful, dangerous) and possible transitions between them depending on the magnitude of the electric power, absorbed by employee’s body. Proposed are new levels of working conditions associated with electric power effect under proposed techniques. Set forth are the results of evaluation of occupational disease risk using probit-function and the recommendations regarding the arrangements aimed at reduction thereof.
PL
W pracy badano regularność w występowaniu ryzyka choroby zawodowej pracowników, spowodowane przez pole elektromagnetyczne, o częstotliwości przemysłowej w wysokonapięciowych instalacjach elektrycznych. Rozpatrywane były główne warunki bezpieczeństwa instalacji elektrycznych (optymalne, dopuszczalne, szkodliwe, niebezpieczne) oraz możliwe przejścia między nimi, w zależności od wielkości energii elektrycznej, pochłanianej przez ciało pracownika. Zaproponowano nowe poziomy warunków pracy, związane z oddziaływaniem mocy elektrycznej, związanych z proponowanymi technikami. W pracy podano wyniki oceny wystąpienia ryzyka choroby zawodowej z wykorzystaniem modelu probit oraz zalecenia, dotyczące ustaleń mających na celu ich zmniejszenie.
first rewind previous Strona / 6 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.