Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 7

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  electric networks
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
The purpose of this research work is to study the issues of the protection of 6–10 kV lines and access ways overvoltage in the electrical networks of modern enterprises of high-energy intensity, as well as the search for real technical opportunities to improve the protection of power lines directly in conditions of their operation. The methodology of this scientific research is based on a combination of methods of system analysis of the principles of the functioning of electric networks of energy-intensive enterprises with an analytical study of the fundamental aspects of ensuring the protection of 6 to 10 kV lines and access ways from overvoltage. The results of the conducted scientific research indicate the relevance of the issues of ensuring the protection of lines and electrical networks of energy-intensive enterprises from overvoltage and the need to develop special technical devices to ensure the proper level of such protection in real conditions. The results and conclusions of this research work are of significant importance for developers and designers of electric networks of enterprises with increased energy capacity, as well as for employees of various power supply systems who, by their occupation, face the tasks of servicing electric networks, which include lines and access ways with specified operating voltage parameters and ensuring the proper level of safety and practical use of these electric networks of energy-intensive enterprises.
PL
Celem pracy badawczej jest zbadanie problematyki ochrony linii 6–10 kV i przepięć w miejscach dostępu w sieciach elektroenergetycznych nowoczesnych przedsiębiorstw o dużej energochłonności, a także poszukiwanie realnych technicznych możliwości poprawy ochrony linii elektroenergetycznych bezpośrednio w warunkach ich eksploatacji. Metodologia niniejszych badań naukowych opiera się na połączeniu metod analizy systemowej zasad funkcjonowania sieci elektroenergetycznych przedsiębiorstw energochłonnych z analitycznym badaniem podstawowych aspektów zapewnienia ochrony linii od 6 do 10 kV oraz miejsc dostępu do nich od przepięcia. Wyniki przeprowadzonych badań wskazują na istotność zagadnień zapewnienia ochrony linii i sieci elektrycznych przedsiębiorstw energochłonnych przed przepięciami oraz konieczność opracowania specjalnych urządzeń technicznych zapewniających właściwy poziom tej ochrony w warunkach rzeczywistych. Wyniki i wnioski z tej pracy badawczej mają istotne znaczenie dla wykonawców i projektantów sieci elektrycznych przedsiębiorstw o podwyższonej energochłonności, a także dla pracowników różnych systemów zasilania, którzy z racji wykonywanego zawodu mają do czynienia z zadaniami serwisowania sieci elektrycznych obejmujących linie o określonych parametrach pracy oraz odpowiadają za odpowiedni poziom bezpieczeństwa i praktycznego użytkowania tych sieci elektrycznych przedsiębiorstw energochłonnych.
EN
The peculiarities of the operation of distributed generation systems lead to a change in the requirements for the reliability and safety of the power distribution systems in which they are integrated. To meet the increased requirements, continuous monitoring of the insulation parameters (active resistance and capacitance to ground) is often used with operating artificial non-industrial frequency operational signals introduced into the network. In the case of a sudden touch, such a system is not effective, since the response time of the protection device, which consists of the signal processing time and the operating of the actuator, is crucially important. For the used operational signals with a frequency of 100 and 200 Hz, the processing time using the Fourier transform is 10 ms for 100 Hz and 5 ms for 200 Hz. Considering that the response time of the fastest actuators (based on vacuum switches) is from 3 to 7 ms, this is a rather significant period of time. To develop an effective resolver system, the capabilities of the Matlab environment were used to determine the most successful design of an analog prototype (Butterworth, Bessel, Chebyshev and Cauer of 6th order) for an operational signal with a frequency of 200 Hz. As a result, the processing time was established, which varies widely from 3.5 to 19 ms. Taking into account the known indicators, namely the frequency and number of operational signals, a signal processing system was developed using the vector-matrix analysis method. As a result of modeling the processing characteristics of functional signals (at a sampling rate of 1 kHz), the system quick-response was 3 ms, with the possibility of its further decrease as its productiveness increases.
EN
When comparing the performance indicators of electrical networks with different types of neutral grounding, along with the fulfilment of the requirement to ensure reliability of power supply to consumers, serious attention is drawn to the main network parameters influencing the performance of power supply systems. Analysis of research and its results, reported above, on the influence of the neutral ground of power networks on the reliability and electrical safety conditions of the power supply systems as a whole, on the damage of distribution networks and electrical equipment as well as on the working capacity of relay protection devices, provides an opportunity to estimate each specific operation mode of the neutral and to develop recommendations aimed at strengthening the positive indicators of the corresponding modes. Other things being equal, reliability of power supply to electrical receivers or reliability of distribution networks is mainly determined by the damage to network elements and the performance of relay protection devices. The degree of influence of these factors on the reliability of distribution networks depends on the neutral mode, which in turn determines the level of internal overvoltages and the nature of transient processes at earth fault.
EN
Introduction and aim: Analysis of percolation current on electric networks (i.e. triangular, square, and hexagonal) in matrix notation has been presented in this paper. It is a new proposition of matrix analysis for specific electric circuits. The elaborated percolation models were verified on the base of given percolation thresholds. Material and methods: Some current characteristics for the right networks have been determined in dependence of random shorted bounds. Both analytical and numerical methods in MathCAD program were shown in the paper. Results: If the number of bounds in the network is higher, than the value of percolation current is smaller. It was observed, that the curves of percolation current have the familiar forms and increasing trend. The value of percolation current for given lattice and the same number of loops is dependent from its structure of bounds. Conclusion: For selected number of shorted bounds of all analysed lattices its decreasing means a decreasing of percolation current value.
PL
Wstęp i cel: W niniejszej pracy została pokazana analiza prądu perkolacji na sieciach elektrycznych (tj. trójkątnej, kwadratowej i sześciokątnej). Jest to nowa propozycja analizy macierzowej dla wybranych sieci elektrycznych. Opracowane modele perkolacji zostały zweryfikowane na podstawie podanych progów perkolacji. Materiał i metody: Pewne cechy prądu dla odpowiednich sieci zostały określone w zależności od przypadkowego zwierania oczek sieci. W artykule zostały przedstawione zarówno metoda analityczna jak i numeryczna w programie MathCAD. Wyniki: Jeśli liczba w oczek sieci jest duża, to wartość prądu perkolacji jest mała. Stwierdzono, że krzywe prądu perkolacji mają podobny kształt i trend wzrastający. Zwiększenie związanego liczby powoduje pewne wygładzenie przesączania aktualnej krzywej. Wartość prąd perkolacji dla danej siatki i tej samej liczbie oczek zależy od jej struktury wiązań. Wniosek: Dla wybranej liczby zwartych oczek wszystkich analizowanych sieci jej spadek oznacza obniżenie wartości bieżącej wartości prądu perkolacji.
PL
Podano obowiązujące przepisy określające parametry energii elektrycznej. Omówiono źródła i skutki zakłóceń w sieciach energetycznych oraz znormalizowane wymagania dotyczące metod pomiarowych i aparatury wykorzystywanej do oceny jakości energii. Przedstawiono przykładowe wyniki pomiarów przeprowadzonych w sieciach i obiektach ZE Opole.
EN
List of the obligatory regulations specifying the parameters of electric energy. Sources and effects of disturbances in electric networks. Standardized requirements on the measuring methods and instruments used for assessment of the quality of energy. Examples of the results of measurements made in networks and the Opole electric power station.
PL
Większość analityków widzi szansę na rozwój krajowego sektora stacjonarnych publicznych sieci telekomunikacyjnych w postępującej liberalizacji rynku oraz w stale rosnącym zainteresowaniu świadczeniem usług dostępu do sieci internet. Jednakże nowe firmy operatorskie czeka wiele niespodzianek, w tym niekoniecznie przyjemnych.
7
Content available remote Linear 2-D Systems of the Siepiński Gasket Type
EN
The paper is aimed on 2-D models for fractal linear structures composed of identical passive elements and connected into the Sierpiński triangle. A new approach for evaluation of the distribution of appropriate signals within the whole structure is established. The efficiency of the method is demonstrated and well proved. Distinguished properties of the established distribution are demonstrated. Illustrative example is also presented.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.