EN
A comparative analysis of filtration performance of tangential and axial inlet reverse-flow cyclone separators and vortex tube separators is presented. The study showed that vortex tube separators are characterized by a quality factor q several time higher than tangential inlet reverse-flow cyclone separators. The cyclone separators yield low separation efficiency and low filtration performance at low air flow rates at low air volumes aspired by the engine at low speed. One of the well-known and not commonly used methods to improve separation efficiency is to apply electric field. An original design of a vortex tube separator with insulators generating electric field in the area of aerosol flow is presented. High voltage was applied to the cyclone separator housing and its swirl vane. A special method and test conditions were developed for cyclone separators with electric field. Separation efficiency, filtration performance and pressure drop across the cyclone separator in two different variants were determined. The tests were carried out at five inlet velocity of cyclones υ0 = 1.75; 3.5; 7.0; 10.5; 14 m/s at an extraction rate of m0 = 10%, and at an average dust concentration in the inlet air of s = 1 g/m3. Using the electric field in the area of a swirling aerosol stream resulted in an increase (over 12% – φ c = 96.3%) in separation efficiency at inlet velocity of cyclone ranging from 1.75 to 3.5 m/s. An increase in separation efficiency at other inlet velocity of cyclone is minor and does not exceed 3‒4%.
2
Content available remote Parallel implementation of a PIC simulation algorithm using OpenMP
EN
Particle-in-cell (PIC) simulations are focusing on the individual trajectories of a very large number of particles in self-consistent and external electric and magnetic fields; they are widely used in the study of plasma jets, for example. The main disadvantage of PIC simulations is the large simulation runtime,which often requires a parallel implementation of the algorithm. The current paper focuses on a PIC1d3v simulation algorithm and describes the successful implementation of a parallel version of it on a multi-core architecture, using OpenMP, with very promising experimental and theoretical results.
EN
Analytical relations, describing the electrical fields of cylindrical piezoceramic radiators with circular polarization as a member of the cylindrical systems with the baffle in the inner cavity, using the related fields method in multiply connected regions were obtained. Comparative analysis of the results of numerical experiments performed on the frequency characteristics of the electric field of the radiating systems for different modes of radiation allow to establish a number of subtle effects of the formation of the electric field of radiators.
EN
The aim was to investigate occupational exposure to electric and magnetic fields during tasks at ground or floor level at 110 kV substations in Finland and to compare the measured values to Directive 2013/35/EU. Altogether, 347 electric field measurements and 100 magnetic field measurements were performed. The average value of all electric fields was 2.3 kV/m (maximum 6.4 kV/m) and that of magnetic fields was 5.8 µT (maximum 51.0 µT). It can be concluded that the electric and magnetic field exposure at ground or floor level is typically below the low action levels of Directive 2013/35/EU. The transposition of the directive will not create new needs to modify the work practice of the evaluated tasks, which can continue to be performed as before. However, for workers with medical implants, the exposure may be high enough to cause interference.
EN
The electromagnetic fields associated with a lightning channel can have an effect on power lines by creating induced voltages on the power networks. The shape of a channel base current especially up to the first value has a great effect on the radiation components of electromagnetic fields, while the electromagnetic fields due to lightning can be evaluated by considering the different field components. This study considers the behavior of the radiation component of the electric field versus current time front changes as the radiation component is a critical component of the electric field. The results show that the radiation component has a greater effect on the total field at far distances from the lighting channel while this effect will be larger for close and intermediate distances from the lightning channel only during the initial time periods. Furthermore, the results illustrate that the current time front has an inverse relationship with the radiation component of an electric field at different distances from the lighting channel.
PL
W artykule przedstawiono analizę wpływu zmian czoła fali prądowej, wyładowania atmosferycznego na poziom emitowanego promieniowania pola elektrycznego i oddziaływanie tego pola na linie energetyczne. Zbadano także zawartość promieniowania pola elektrycznego w całkowitym wytworzonym polu w zależność od odległości od wyładowania.
EN
The development of an arc along the polluted surface depends to a great extent on the electric field of streamer at the arc head and the current densities in the wet polluted layer and arc. To investigate the parameters that vary depending on the arc length during the development of an arc, a simplified model of development arc along the polluted surface was established. Based on the numerical calculation of characteristic quantities of electric field and current density in the simplified model, the influencing factors on the development of arc were investigated.
PL
W artykule opisano budowę uproszczonego modelu tworzenia się łuku elektrycznego przez zanieczyszczoną powierzchnię. Na podstawie analizy parametrów pola elektrycznego i gęstości prądu w modelu, określono i zbadano wpływ poziomu zanieczyszczeń powierzchni na rozwój łuku.
PL
Na przekroju kilkudziesięciu ostatnich lat obserwowany jest duży wzrost liczby urządzeń wytwarzających pola elektromagnetyczne, który przekłada się na coraz większe zainteresowanie społeczeństwa zakresem oddziaływania tych urządzeń na środowisko. Obok tradycyjnych źródeł pól elektromagnetycznych jakimi są przesyłowe linie elektroenergetyczne, trakcje kolejowe czy tradycyjne nadajniki radiowo - telewizyjne, masowo pojawiają się nadajniki telefonii komórkowej i inne urządzenia radiokomunikacyjne. Pracownicy i studenci Wydziału Elektrotechniki i Informatyki Politechniki Lubelskiej przeprowadzili badania terenowe w dwóch miastach, w zakresie pomiaru natężeń pól elektrycznych i magnetycznych niskich częstotliwości oraz natężenia pola elektromagnetycznego w wysokich częstotliwościach. W artykule przedstawiono wyniki pomiarów oraz ich odniesienie do dopuszczalnych limitów.
EN
The number of devices that produce electromagnetic fields is growing for decades. This translates into a growing public interest in range of influence of these devices on the environment. In addition to traditional sources of electromagnetic fields such as transmission power lines, rail traction or traditional radio- television transmitters, mass are built mobile transmitters and other radio communications equipment. Staff and students of the Lublin University of Technology measurements conducted in two cities - Lublin and Naleczow. The tests involved measuring intensities of electric and magnetic fields at low and high frequencies. The article presents the results of measurements and their reference to limits.
EN
This paper deals with the reduction of electric and magnetic field emissions caused by the single-circuit 400 kV overhead power line. These emissions are especially important on the border of the overhead power line right of way, where electromagnetic field emissions should be under prescribed limits. This paper deals with the two solutions. Firstly the usage of higher to wers is investigated, while secondly the new conductor arrangements is defined in the optimization process.
PL
W artykule poruszono problem ograniczenia emisji pola elektromagnetycznego wywolanego linią elektroenergetyczną 400 kV. Emisja ta jest szczególnie istotna na obszarze dostępnym (right-of-way) gdzie emisja pola elektromagnetycznego podlega szczególnym restrykcjom. Mykul pokazuje dwa rozwiązania: użycie wyższych slupów energetycznych lubli zastosowanie nowych ustawień przewodów energetycznych.
9
Content available remote Emissions of electromagnetic fields caused by sagged overhead power lines
EN
Nowadays people became aware of the overhead lines and their emissions of electromagnetic fields. This work presents a method for calculation of the electric field strength and magnetic field density caused by the overhead power lines at the ground le vel. The method considers the conductor sagging. It is shown that the sagged conductors can be replaced with the properly placed straight conductors without substantial decrease in accuracy of calculated results.
PL
Obecnie daje się zauważyć wzrost świadomości społecznej istnienia linii elektroenergetycznych napowietrznych i emitowania przez nie pola elektromagnetycznego. Artykuł prezentuje metodę obliczeń natężenia pola elektrycznego i strumienia magnetycznego od linii elektroenergetycznej na poziomie ziemi. Metoda uwzględnia obniżenie (zwis) przewodu. Pokazano, że zwis przewodów może zostać zastąpiony przez właściwie umieszczone proste przewody bez istotnej utraty dokładności.
PL
Transportowy system nadzoru stanowi przestrzennie ukształtowany zbiór składników współdziałających ze sobą w ramach osiągnięcia założonego poziomu bezpieczeństwa np. na dworcu kolejowym, lotniczym, porcie morskim. Występujące zakłócenia elektromagnetyczne w procesie eksploatacji systemu nadzoru mogą spowodować wystąpienie uszkodzeń katastroficznych lub mogą być przyczyną obniżenia jakości pracy systemów poprzez - np. zwiększenie prawdopodobieństwa fałszywego alarmu.
EN
The transport systems of supervision is special structured set of components that interact which each other in order to achieve the complex level of safety, for example at the railway station, airport or seaport. Electromagnetic interference that occurs in operating process of control system may cause catastrophic damage or may result in quality reduction of systems by increasing the probability of false alarm.
EN
Because the application of pressure in electro-dewatering of wastewater sludge (and consequent compression) affects processes of electroosmosis and electrophoresis, the study aimed at determining the effect of vacuum and constant electric field on the specific resistance of sludge and quality of filtrate. It was found that both the current intensity and direction affects the biogen content in sludge dewatering filtrate. An increase in the intensity of the current applied to the filtering barrier was accompanied by an increase in the effectiveness of the removal of ammonium nitrogen (filtering barrier as an anode) and orthophosphates (filtering barrier as a cathode). A constant electric field was shown to considerably affect the specific resistance of sludge filtration.
EN
We have investigated computationally (B3PW91/6-31G**) the effects of electric fields upon certain properties - dipole moments, energies, geometries and electrostatic potentials – of two prototypical energetic molecules, nitromethane and dimethylnitramine. Fields of various strengths and in different directions were considered. The stronger fields significantly polarized the molecular charge distributions, especially when applied parallel to the C-NO2 and the N-NO2 bonds. These directions correspond to the principal polarities of the ground-state molecules, which these parallel fields either reinforce or counteract. With respect to geometries, the changes are primarily conformational, e.g. rotation of the methyl groups or inversion of the pyramidal nitrogen in (H3C)2N-NO2.
13
Content available remote Visualization of dust particles motion in back discharge
EN
The back discharge takes place in an industrial electrostatic precipitation process, especially in coal-fired power plants whose operation is based on low-sulfur coal. This type of discharge occurs simultaneously with corona discharge on an electrode covered with a high-resistivity dust layer. The charge that accumulates on the dielectric layer surface is responsible for an increase in the magnitude of electric field within the dielectric layer and a decrease in the magnitude of electric field between the electrodes. The breakdown of dielectric layer increases the discharge current and the re-entraining of dust particles from collecting electrode into the flowing gas. The motion of dust particles emitted from the collecting electrode and an air flow pattern were investigated. Additionally, acrylic powder layer placed between a mica plate with a small pinhole and the plate electrode was also used in the experiments in order to generate a repeatable back discharge.
PL
Wyładowanie wsteczne występuje podczas użytkowania elektrofiltrów w przemyśle wykorzystującym niskozasiarczony węgiel. Wyładowanie wsteczne pojawia się wówczas, gdy elektrodę osadczą pokrywa warstwa pyłu o dużej rezystywności. Gromadzący się na powierzchni warstwy ładunek powoduje wzrost natężenia lokalnego pola elektrycznego w obszarze warstwy dielektrycznej oraz spadek natężenia pola elektrycznego w przestrzeni międzyelektrodowej. Wskutek przebicia warstwy dielektrycznej wzrasta natężenie prądu wyładowania oraz emisja pyłu zebranego na elektrodzie zbiorczej do przepływającego powietrza. Przedstawiono ruch cząstek pyłu emitowanych z elektrody zbiorczej oraz strukturę przepływu powietrza wokół elektrody wyładowczej. W badaniach wykorzystano również układ modelowy, w którym warstwą dielektryczną była płytka miki, a zamiast pyłu z elektrofiltru wykorzystano pył akrylowy.
14
Content available remote A space-charge problem including trapped positive charge. A case of solar cell
EN
A theoretical description of an interior of a solid for space charge is continued. Carrier generation and recombination conditions are considered. On this basis it is found that the metal-solid-metal system can act as a perfect blocking diode. A solar cell problem is discussed.
PL
Problem formowania się ładunku przestrzennego w ciele stałym jest kontynuowany. Rozważa się warunki generacji i rekombinacji nośników. Na tej podstawie stwierdza się, że układ metal-ciało niemetaliczne-metal może działać jak idealna dioda blokująca. Rozwija się problematykę baterii słonecznej.
15
EN
The paper deals with the 3-D numerical estimation of the electric field excited in the human environment by power engineering objects. A proposed mathematical model in common with the employed hybrid numerical technique combining both the boundary element technique and the charge simulation method enables the field analysis in zoned heterogeneous regions of complex geometry. The appropriate mathematical equations and formulae have been derived. Solutions of two selected practical problems have been presented.
PL
W artykule przedstawiono numeryczną metodę wyznaczania rozkładów pola elektrycznego wytwarzanego w środowisku człowieka przez obiekty elektroenergetyczne. Zaproponowany model matematyczny pola w powiązaniu z hybrydową metodą numeryczną łączącą metodę elementów brzegowych z metodą ładunków symulowanych umożliwia analizę pola w obszarach o skomplikowanej geometrii. Wyprowadzono wzory i równania matematyczne wykorzystywane w omawianej metodzie obliczeniowej. Przedstawiono wyniki analizy pola dla dwóch wybranych przykładów praktycznych.
EN
A model allowing determination of the electric field and potential in the presence of a space charge (positive ions) determined on the basis of the knowledge of efficient ionisation factor alpha(-) has been developed. The distribution of the space charge is done in spherical concentric volumes. The calculation is developed in a hyperboloidal point-barrier-plane arrangement under a positive voltage. The polarisation field is taken into account. To calculate the electric field the finite element method has been applied. Results show that electric stress in the air gap decreases due to the space charge left in the point-barrier gap, but it increases suddenly at the handle of the avalanches and on the barrier surface facing the point. This latter effect related to the presence of the dielectric barrier is due to the polarisation charge. The space charge variation is not smooth. It presents a sudden increase when alpha(-) changes.
PL
Przedstawiono model umożliwiający obliczenia rozkładu potencjału i pola elektrycznego w obecności dodatniego ładunku przestrzennego, wyznaczonego w oparciu o znajomość efektywnego współczynnika jonizacji alfa(-). Ładunek przestrzenny występuje w wyodrębnionej przestrzeni kulistej. Analiza dokonywana jest w układzie elektrod ostrze hiperboloidalne - bariera - płyta z dodatnią biegunowością ostrza. W analizie uwzględniono pole polaryzacyjne bariery. W obliczeniach polowych wykorzystano metodę elementów skończonych. Uzyskano potwierdzenie, że ładunek przestrzenny powoduje zmniejszenie natężenia pola, które wzrasta gwałtownie w przypadku procesów lawinowych, gdy powierzchnia ładunku przestrzennego dociera do ostrza. Taki efekt bariery dielektrycznej związany jest z polaryzacją ładunku. Wartość ładunku przestrzennego zmienia się gwałtownie ze zmianą współczynnika alfa(-).
17
Content available remote Artificial neural network approach to mixed boundary conditions identification
EN
The electric field model of a copper electrodeposition process on printed circuit board (PCB) by means of ultrasonic field is presented in this paper. The problems of copper plating, the current distribution in through-holes and ultrasonic intensification of the electrodeposition process are the subject of many investigations. The result of our measurement experiment indicates that a copper layer in a through-hole grows faster than on the flat surface of PCB. On the basis of measurements, the numerical (FEM) model has been proposed. The inverse problem have been formulated for those two coupled fields (by boundary conditions), making us possible to control the current density and the layer thickness. To solve this problem the artificial neural network (ANN) has been applied.
PL
Praca dotyczy modelowania procesu galwanicznego osadzania miedzi w polu ultradźwiękowym na płytkach obwodów drukowanych. Zagadnienia związane z osadzaniem miedzi wewnątrz wąskich otworów przelotowych i związane z tym trudności otrzymania warstw odpowiedniej jakości są wciąż przedmiotem badań. Zastosowanie pola ultradźwiękowego w tych procesach ma na celu przyspieszenie osadzania oraz poprawę jakości warstw. Przeprowadzone na modelu fizycznym płytki obwodu drukowanego doświadczenia wykazały, że w obecności pola ultradźwiękowego grubość otrzymanej w otworze warstwy jest większa niż na płaskiej powierzchni płytki. Na podstawie wyników pomiarów został stworzony model numeryczny układu. Dla pola elektrycznego procesu elektrolizy sprzężonego poprzez warunki brzegowe z polem ultradźdwiękowym sformułowano zagadnienie odwrotne. Rozwiązanie tego problemu daje możliwość kontroli rozkładu gęstości prądu na granicy faz metal - elektrolit, a tym samym grubości nanoszonej warstwy. Problem rozwiązano stosując metodę sztucznych sieci neuronowych.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.