Ograniczanie wyników
Czasopisma help
Autorzy help
Lata help
Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Powiadomienia systemowe
  • Sesja wygasła!

Znaleziono wyników: 23

Liczba wyników na stronie
first rewind previous Strona / 2 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  electric current
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 2 next fast forward last
EN
In this research paper, the problem of studying the effectiveness of ozone in the process of water treatment was considered. In the course of the scientific work, a review of domestic and foreign literature was conducted; its advantages and disadvantages were considered. The research paper presented the theoretical and practical methods of water purification with ozone. The main factors influencing the efficiency of the technology in the process of water purification were also considered. It was established that as a technological method of water purification, the efficiency of the ozonation process includes not only the cost of electricity, but also the efficiency of its mixing, ozone dissolution in treated water. In addition, special attention is paid to the final stage of mixing the ozone-air mixture with treated water. From the results obtained, it can be seen that after primary ozonation, the concentrations of chromium, oxidation of permanganate, iron, petroleum products, metal ions and other pollutants significantly decreased. During further water purification, organic and inorganic pollutants are removed in the future (completely or up to the requirements of the standard). However, calcium, magnesium, sulfates, chlorides, pH value, alkalinity and hardness practically do not change. The water quality after primary ozonation according to bacteriological indicators met the requirements of the standard.
2
Content available remote Ogniwa paliwowe - zalety i problemy eksploatacji
PL
Ogniwa paliwowe są coraz szerzej obecnie stosowane zarówno w życiu codziennym, jak i w gospodarce. Omówieniu korzyści ze stosowania tych nowych źródeł prądu elektrycznego i pojawiających się wówczas niebezpieczeństw poświęcony jest niniejszy artykuł.
EN
During a study of the combustion process of a direct polarity electric arc, a directly proportional dependence of the electric current value on the degree of cold plastic deformation of carbon steel used as an electrode was found. To calculate the value of the electric current during arc burning, in the indicated ratio, it was proposed to replace the surface tension force of the liquid metal with the surface tension of ferrite of plastically deformed carbon steel. Calculation of the ferrite’s surface tension value on the deformation degree of the steel under study through the size of the coherent scattering regions was used to explain the observed dependence of the electric current during arc burning. From the analysis of the considered correlation ratios, it was found that with an increase in the cold deformation degree, the refinement of the coherent scattering regions results in the ferrite’s surface tension increase and consequently, to an increase in the electric current during arc burning. Comparative analysis of the obtained results of calculating the value of electric current during arc burning through the surface tension of ferrite of cold-deformed carbon steel showed a fairly good coincidence with experimental data. The differences did not exceed 9%.
4
Content available Właściwości elektryczne niektórych ryb
PL
Niektóre gatunki ryb, należące do rodzin: drętwy, strętwy, mruki i sum elektryczny, wyewoluowały niezależnie narządy elektryczne. Ryby te należą do gromad chrzęstno- i kostnoszkieletowych. Wytwarzane napięcie elektryczne u tych ryb służy do obezwładniania zdobyczy lub odstraszania napastników. Niektóre ryby swe narządy elektryczne wykorzystują do elektrolokacji i orientacji w środowisku.
PL
Wyłączniki różnicowoprądowe są aparatami stosowanymi jako jeden z uzupełniających środków ochrony przed porażeniami. Jako środek uzupełniający muszą być stosowane łącznie z innymi środkami ochrony. W zależności od typu mogą reagować na prąd elektryczny o różnych przebiegach. Konieczność ich stosowania wynika z przesłanek technicznych oraz z zapisów zawartych w rozporządzeniu określającym warunki techniczne dla budynków oraz przywołanych w nim Polskich Normach.
EN
Residual current devices are devices used as one of the supplementary means of protection against electric shocks. As a complementary measure, they must be used in conjunction with other means of protection. Depending on the type, they can respond to electric currents of different waveforms. The necessity of their use results from technical premises and provisions included in the regulation defining technical conditions for buildings and Polish Standards referred to therein.
PL
Podstawowym czynnikiem, który ogranicza maksymalną siłę pociągową na obwodzie kół napędnych oraz największą wartość siły hamowania jest przyczepność występująca w styku koła lokomotywy z szyną. W artykule przeanalizowano możliwe sposoby zwiększenia współczynnika przyczepności oraz zaprezentowano autorskie rozwiązanie dla lokomotyw spalinowych wykorzystujące przepływ prądu elektrycznego z prądnicy przez strefę styku koła z szyną. Przedstawiono wyniki badań teoretycznych, w tym schematy elektryczne układu, laboratoryjnych na stanowisku badawczym oraz otrzymane z badań eksploatacyjnych układu w lokomotywie spalinowej. Wyniki badań wykazały zwiększenie współczynnika przyczepności przy oddziaływaniu prądem elektrycznym na powierzchnię styku koła z szyną.
EN
The basic factor that limits the maximum tangential tractive effort and the greatest value of braking force is the adhesion occurring in the contact of the locomotive wheel - rail. The article analyzes possible ways to increase the coefficient of adhesion and presents a proprietary solution for diesel locomotives using the flow of electric current from a generator through the wheel-rail contact zone. The results of theoretical tests, including electrical diagrams of the system, laboratory tests on the test stand and obtained from operational tests of the system in the diesel locomotive are presented. The test results showed an increase in the coefficient of adhesion when electric current flows through the contact surface of the wheel - rail.
7
Content available remote Analiza wpływu prądu elektrycznego na organizmy żywe
PL
W artykule przedstawiono podstawowe definicje związane z wpływem prądu elektrycznego na organizmy żywe oraz skutki przepływu prądu elektrycznego. Uwzględniono również graniczne dopuszczalne napięcia i prądy rażeniowe dla ludzi i zwierząt hodowlanych.
EN
The article presents basic definitions related to the influence of electric current on living organisms and the effects of electric current flow. There are also included the permissible voltage limits and currents for humans and farm animals. Title: Analysis of the influence of an electrical current on a living organisms.
8
Content available Prąd elektryczny zagrożeniem dla strażaków
PL
Strażacy, prowadząc działania ratowniczo-gaśnicze w budynkach, w wypadkach związanych z ruchem drogowym lub kolejowym, narażeni są na zagrożenia wynikające z obecności urządzeń i instalacji pod napięciem. Sieci i instalacje elektryczne są nieodzownym elementem nowoczesnej infrastruktury. Użytkownicy urządzeń elektrycznych mogą być narażeni na różnego rodzaju zagrożenia, zależnie od budowy urządzeń i odbiorników energii elektrycznej, sposobu wykonania instalacji, niedopasowania urządzeń do warunków technicznych eksploatacji i otoczenia oraz od niezadowalających umiejętności personelu obsługującego te urządzenia. W związku z tym strażak przystępując każdorazowo do działań, zobligowany jest do wyeliminowania zagrożeń wynikających z możliwości wystąpienia przepływu prądu elektrycznego przez jego ciało podczas akcji. Z reguły sprowadza się to do odłączenia akumulatorów w pojazdach mechanicznych, odłączenia sieci lub instalacji elektrycznych doprowadzonych do budynku przez Pogotowie Energetyczne lub wyłączenia zasilania z użyciem wyłącznika głównego prądu. Jednakże różnorodność urządzeń oraz instalacji elektrycznych funkcjonujących w obrębie konkretnego obiektu może budzić wątpliwości, czy „wszystko” odłączono i nie występuje niebezpieczeństwo porażenia prądem elektrycznym. Na tą ewentualność każdy strażak wyposażony jest w odpowiedni sprzęt, obuwie dielektryczne oraz detektory prądu przemiennego. Niemniej jednak, ważne jest, aby każdy strażak posiadał elementarną wiedzę na temat zasad postępowania w obrębie czynniej sieci elektroenergetycznej oraz negatywnego oddziaływania prądu elektrycznego na jego organizm. W artykule zawarto informacje na temat wpływu przepływu prądu elektrycznego przez organizm człowieka, metod ograniczania jego negatywnych skutków oraz zasad postępowania podczas zdarzeń z udziałem prądu elektrycznego, w aspekcie przepisów prawa i ochrony osobistej strażaków.
EN
Firefighters, while carrying out rescue and extinguishing operations in buildings, in cases related to road or rail traffic, are exposed to hazards resulting from the presence of electric voltage equipment and installations. Electrical grid and installations are an indispensable element of modern infrastructure. Users of electrical devices may be exposed to various types of hazards, depending on the construction of devices and electric energy receivers, the method of installation, equipment mismatches for the technical conditions of use and surroundings, as well as the unsatisfactory skills of the personnel operating these devices. Therefore, each time a firefighter joins the action, they are obliged to eliminate threats resulting from the possibility of electric current flow through his body during the action. As a rule, this amounts to disconnecting the batteries in motor vehicles, disconnecting the network or electrical installations brought to the building by the Energy Emergency Service or switching off the power supply using the main power switch. However, the diversity of devices and electrical installations functioning within a particular facility may raise doubts whether "everything" has been disconnected and there is no danger of electric shock. For this eventuality, every firefighter is equipped with appropriate equipment, dielectric footwear and AC detectors. Nevertheless, it is important that every firefighter has an elementary knowledge of the rules of conduct within the active power grid and the negative impact of electricity on his body. The article contains information on the impact of electric current flow through the human body, methods of limiting its negative effects and rules of conduct during events involving electric current in the aspect of law and personal firefighters protection.
PL
W artykule przeanalizowano wypadki przy pracy, które związane były z porażeniem prądem elektrycznym w latach 2005–2017 w zakładach górniczych. Zaprezentowano także dane statystyczne dotyczące wypadków związanych z elektrycznością przez dotyk bezpośredni. Analizę przeprowadzono na podstawie danych udostępnionych przez Główny Urząd Statystyczny oraz Wyższy Urząd Górniczy.
EN
Mechanisation and automation of the extractive processes in mining and the spread of higher-performance machines, are connected with significant increase in electricity demand. Usage of faulty, damaged or incorrectly adjusted euqipment and energy installations may cause to humans employed by mining enterprises some dangerous accidents, caused by the impact of electric current on the human body. Electrical risks manifest in accidents as the possibility of electrical shock or burning from arc flash. The article analyses accidents at work, all electrical shock-related, over the period 2005–2017 at mining plants. There have been also presented the statistical data concerning some electricity accidents by direct contact. The analysis was carried out using data provided by the Statistics Poland and the State Mining Authority.
PL
Opisano historię poznania właściwości elektrycznych ciała człowieka. Przedstawiono badania wartości impedancji ciała człowieka oraz skutków powodowanych prądem rażeniowym.
EN
The article discusses the history of recognition the electrical property of human body. The article discusses the studies of value of impedance of human body and of effects from defeat current.
PL
W pracy zaprezentowano światłowodowy czujnik polarymetryczny wykorzystujący efekt Faradaya zmieniający płaszczyznę polaryzacji światła liniowo spolaryzowanego pod wpływem oddziaływania płynącego prądu w przewodniku. Przedstawiono wyniki analizy wpływu indukowanej dwójłomności w światłowodzie jednomodowym na podstawowe parametry opisujące polaryzację na wyjściu czujnika prądu. Do analizy stanu polaryzacji wykorzystano macierze Jonasa opisujące wszystkie elementy toru optycznego. Dokonano obliczeń numerycznych parametrów stanu polaryzacji: natężenie światła, azymutu i eliptyczność wiązki wyjściowej dla trzech konfiguracji polarymetrycznego czujnika natężenia prądu. Przedstawione wyniki badań stanowią materiał źródłowy przy wyborze konkretnego układu pomiarowego światłowodowego czujnika prądu wykorzystującego polarymetr.
EN
In this latter the fiber optics polarimetric current sensor using Faraday effect, which changes the polarization plane of linear polarized light is presented. The results of analysis of the impact of linear birefringence induced in singlemode fiber on the basic parameters describing the polarization on the output of the current sensor were described. For the analysis of the state of polarization on the output of the sensor the Jones matrix which describe all the elements of the optical circuit were used. The numerical parameters of the state of polarization of light intensity, azimuth and ellipticity of the output beam for the three configurations polarimetric sensor current were calculated. The results are the basis to the selection of a particular measurement system using fiber optic current sensor polarimeter.
PL
W artykule opisano historię poznania właściwości elektrycznych ciała człowieka. Pierwsze eksperymenty działania prądu elektrycznego na człowieka były wykonywane dla sensacji. Rozwój elektrotechniki przyczyniał się do poznania wpływu prądu na ciało człowieka. Przedstawiono badania wartości impedancji ciała człowieka oraz skutki spowodowane prądem rażenia. Uwzględniono badania elektropatologiczne wykowywane w ostatnich latach.
PL
Artykuł omawia kolejno zagadnienie wytwarzania napięcia elektrycznego przez niektóre gatunki ryb, narządy elektryczne u ryb i zjawisko elektrolokacji występujące u ryb. Następnie autor opisuje bliżej 11 gatunków ryb zdolnych do wytwarzania prądu elektrycznego i relacjonuje historię badań ryb elektrycznych. Artykuł kończy się krótkim podsumowaniem i wykazem literatury zawierającym 9 pozycji.
EN
The article discusses in turn the problem of generation the electric voltage by some kinds of fishes and phenomenon of electrolocation by fishes. Than author describes precisely 11 kinds of fishes capable tor generation the electric voltage and relates history of research of electric fishes. In the end of article is the short recapitulation and list of literature contained 9 elements.
PL
W artykule przedstawiono dane statystyczne dotyczące przyczyn wypadków przy pracy związanych z elektrycznością oraz przeanalizowano wypadki będące odchyleniem od stanu normalnego związane z elektrycznością przez dotyk bezpośredni w latach 2005–2012. Wyszczególniono ponadto przyczyny techniczne, organizacyjne i ludzkie wypadków przy pracy oraz przeprowadzono ich analizę na podstawie danych udostępnionych przez Główny Urząd Statystyczny.
EN
The article presents the statistics concerning the causes of accidents at work due to electricity and the analysis of accidents which are a deviation from the normal state related to the direct contact with electricity in 2005–2012. The article also specifies the technical, organizational and human causes of accidents at work and presents their analysis based on data provided by the Central Statistical Office.
PL
W pracy przedstawiono wyniki badań eksperymentalnych dotyczących korelacji pomiędzy niepowtarzalnością pracy indykowanej (jednym z głównych parametrów pracy silnika spalinowego), a fluktuacjami prądu elektrycznego wytwarzanego w agregacie prądotwórczym zasilanym LPG. Omówiono stanowisko badawcze, metodykę pomiarów oraz przedstawiono wyniki badań korelacji fluktuacji pracy indykowanej z fluktuacjami natężenia prądu. W przypadku jednocylindrowego agregatu prądotwórczego stwierdzono bardzo wyraźny związek między pracą indykowaną silnika spalinowego, a energią elektryczną obliczoną w przedziale czasowym odpowiednio przesuniętym kątowo względem początku cyklu pracy silnika. Nieco gorsza jest korelacja między amplitudą prądu elektrycznego i pracą indykowaną.
EN
The results of investigation of the correlation between fluctuation of indicated work (one of the main parameters of the work internal combustion engine) and fluctuation of electric current from generating set fueled LPG gas are presents. The test stand, measurement methodology and the results of the correlation between fluctuations of indicated work and current fluctuations are showed. A clear relationship between engine indicated work and an electric energy calculated in time interval angularly shifted regarding the beginning of engine cycle was stated in the case of single-cylinder generating set. A little worse correlation between amplitude of electric current and indicated work was achieved.
PL
Już w średniowieczu marzeniem człowieka było stworzenie czegoś z niczego. Wystarczy wspomnieć o złocie. Wtedy nikomu się to nie udało, a dziś jest rzeczywistością. Dowodem tego jest ekspansywny trend budowy coraz to nowych instalacji biogazu. Dzięki inteligentnemu zastosowaniu surowców odnawialnych w połączeniu z niezawodną techniką sterowania powstają samowystarczalne jednostki, które automatycznie dostarczają prąd niemal prosto z pola.
PL
Wyłączniki różnicowoprądowe to jeden ze środków ochrony przeciwporażeniowej przed dotykiem pośrednim oraz przed pożarem w sieciach niskiego napięcia. Są one obecnie jednym z najbardziej rozpowszechnionych sposobów ochrony życia ludzkiego przed porażeniem prądem elektrycznym.
first rewind previous Strona / 2 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.