In rotating machinery, actions of the moving parts take place at specific angular positions rather than at specific times. For this reason, having a geometrical reference, such as the one provided by an encoder, and studying the Instantaneous Angular Speed (IAS) variations can provide a large amount of information about the health status of the machine. In fact, from the variation of the IAS during the machine loads’ cycle it is possible to identify defects and faults. The current work focuses on the estimation of the IAS through the Elapsed Time (ET) method, using a counter in order to measure the time elapsed between the pulses of an encoder. Both IAS and vibration measurement are conducted on an asynchronous four poles electrical motor driven by 50Hz line current, without load. The study compares the order analysis of both signals. The bearing’s Fundamental Train Frequency is detected using IAS estimation.