Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 7

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  ejektor
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
In this work, a new dual-evaporator CO2 transcritical refrigeration cycle with two ejectors is proposed. In this new system, we proposed to recover the lost energy of condensation coming off the gas cooler and operate the refrigeration cycle ejector free and enhance the system performance and obtain dual-temperature refrigeration simultaneously. The effects of some key parameters on the thermodynamic performance of the modified cycle are theoretically investigated based on energetic and exergetic analysis. The simulation results for the modified cycle indicate more effective system performance improvement than the single ejector in the CO2 vapor compression cycle using ejector as an expander ranging up to 46%. The exergetic analysis for this system is made. The performance characteristics of the proposed cycle show its promise in dual-evaporator refrigeration system.
PL
W artykule opisano konstrukcje zespołów tworzących układy wylotowe silników odrzutowych, ich działanie i spełniane zadania. Zwrócono uwagę na rozwiązania rokujące ich szersze wdrażanie. Wektorowanie ciągu jako ważny sposób umożliwiający radykalny wzrost manewrowości samolotów bojowych wpływających na zmianę taktyki walki powietrznej: Sterowana „cobra” z gonionego czyni goniącego.
3
Content available remote Investigation and modelling of ejector for air-conditioning system
EN
Paper deals with modelling and experimentation on single-phase vapour ejector in application to air-conditioning systems. Particularly very interesting is the case with a low temperature motive heat source which may be applied to solar air-conditioning units. The testing rig, selected test results obtained with refrigerant R-123 as well as numerical modelling results of vapour ejector have been presented in the paper showing reasonably good agreement.
PL
Przeprowadzone badania wahań podciśnienia pod strzykiem w pojedynczym kubku udojowym (bez kolektora) na sztucznym wymieniu przy użyciu krótkich przewodów mlecznych o średnicach wewnętrznych 8, 10 i 13 mm z różnymi końcówkami wyloto-wymi pochylanymi względem poziomu pod kątem 0 – 90° i dla przepływów cieczy 0,5 – 2 l/min. wykazały, że przy największych przepływach w przewodach 8 i 10 mm po-wstają korki z cieczy wywołujące istotne wahania podciśnienia (odpowiednio do 28 kPa i 16 kPa) mało zależne od kąta pochylenia i rodzaju końcówki (różnice do 7 kPa) a które w ogóle nie występują przy średnicy 13 mm. Ponad to zaobserwowano w prze-wodach 8 i 10 mm zjawisko strumienicy (eżektora) odpowiedzialne za oblewanie strzyków mlekiem w czasie doju i zwiększające średnie podciśnienie w takcie ssania nawet o 4 kPa (przy wypływie 2 l/min.) oraz nakładające się odpowiednio na wahania tego podciśnienia.
EN
A research of vacuum hesitation in a single teat cup - without a cluster, with different internal diameter of short milk tube (8 to 13 mm), with different type of outlets inclined at angle 0 to 90o, with employment an artificial udder - prove that for a great flow rate in the tube of diameter 8 and 10 mm has been formed a water congestion which generated crucial vacuum hesitations (properly max. 28 kPa and 14 kPa) weakly dependent on a type or inclination of outlet (max. diversified 7 kPa). In the tube of diameter 13 mm appeared any vacuum hesita-tion. Moreover has been observed an effect of injector in the teat cup with tube of diameter 8 or 10 mm, which increased average vacuum about 2 kPa at derive phase.
EN
The paper describes the development of a novel vapor compression cycle for refrigeration with regenerative use of the potential energy of two-phase flow expansion, which in traditional systems is lost in expansion valves. The new cycle includes a second step compression by an ejector device, which combines the compression with simultaneous throttling of the liquid. The compressor compresses the vapor to approximately 2/3 of the final pressure and additional compression is provided in an ejector, thus the amount of mechanical energy required by a compressor is reduced and the efficiency is increased. Investigations described here were performed under the funding from the US Department of Energy. The thermodynamic model was developed for R22 refrigerant, showing a possible efficiency improvement of 38% as compared to the traditional vapor compression cycle. The theoretical work was followed by building a 10 kW prototype and practical demonstration of 16% energy savings in the first attempt.
PL
W artykule opisano rozwój systemów chłodniczych wykorzystujących energię potencjalną dwufazowego rozprężanie, która jest tracona w tradycyjnych systemach. Nowy cykl zawiera dodatkowy etap sprężania przy użyciu ejektora, który łączy sprężanie z jednoczesnym dławieniem płynu. Kompresor spręża pary do około 2/3 końcowego ciśnienia, a dodatkowe sprężanie ma miejsce dzięki ejektorowi. Z tego względu całkowita energia dostarczana do kompresora jest zmniejszona i tym samym sprawność jest podniesiona. Prace opisane w artykule były prowadzone dzięki wsparciu Ministerstwa Energii USA. Model termodynamiczny został rozwinięty dla czynnika R22, pokazując możliwe podniesienie sprawności o 38% w porównaniu do tradycyjnego cyklu sprężania. Prace teoretyczne zostały wzbogacone przez wybudowany 10kW prototyp i pokaz rzeczywistej oszczędności 16% energii przy pierwszej próbie.
EN
An article describes prototype of multi-layer solar air-conditioner of small refrigerating capacity. In a compact device installed in a hipped roof end or in a wall of building, a ejector refrigerating cycle is supplied with a steam generated in a flat solar collector. Compiling the equations describing the phenomena occur in a steam ejector and the heat exchangers a physical model of the device was proposed. Numerical version of that model was used to create the characteristics of cooperating devices. The obtained characteristics allowed to determine an optimum point of device work. Finally the general guidelines for design engineers were formulated.
PL
Przedstawiono wyniki badań laboratoryjnych podajnika ejektorowego z jednostronnym i dwustronnym odchyleniem strumienia powietrznego, który jest elementem zespołu wysiewającvego pneumatycznego sienika zbożowego. Określono wpływ wymiarów dyfuzora i konfuzora na straty ciśnienia i przepustowość zespołu wysiewającego. Do badań użyto nasion owsa, grochu i jęczmienia przy wydajności dozownika odpowiednio 60, 87,5 i 105 g/s. Określono wymiary podajnika ejektorowego, który przy cisnieniu statycznym wentylatora 7 kPa, szerokości roboczej siewnika 12 m i prędkości agregatu zapewnia wysiew 230 kg/ha owsa, 400 kg/ha grochu i 350 kg/ha jęczmienia.
EN
The results of laboratory investigations of an ejector feeder with one- and two- sided deflections of air stream, which is an element of sowing assembly in a pneumatic grain drill, were presented in the paper. Effects of the diffuser and confusor dimensions on the pressure losses and on the throughput of sowing assembly were determined. Oat, pea and barley seeds were used for tests at the feeder throughputs of 60, 87,5 and 105 g/s, respectively. The dimensions of an ejector feeder were estimated assuming that at static pressure of the fan equal 7 kPa, 12 m working width of the drill and 12 km/h working speed of the machine, the seedin
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.