Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 8

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  efficiency increase
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
This paper presents the development of a cooling apparatus using water in a commercial photovoltaic panel in order to analyze the increased efficiency through decreased operating temperature. The system enables the application of reuse water flow, at ambient temperature, on the front surface of PV panel and is composed of an inclined plane support, a perforated aluminum profile and a water gutter. A luminaire was specially developed to simulate the solar radiation over the module under test in a closed room, free from the influence of external climatic conditions, to carry out the repetition of the experiment in controlled situations. The first case study was published at EEEIC2016 conference where the panel was submitted to different rates of water flow, from 1 L/min to 4 L/min. In the test conditions without cooling apparatus, the panel reached about 70°C and produced approximately 63Wh. With the cooling apparatus with water flow rate of 2 L/min, the module reached about 50°C and produced approximately 77Wh. However, it has been observed that this water flow was overestimated. A second case study was carried out in order to perform the threshold between the flow and the energy produced. The best ratio was flow of 0.6 L/min and net energy of 77.41Wh. Gain of 22.69% compared to the panel without the cooling system. The best water flow rate was of 0.6 L/min and net energy of 77.41Wh. Gain of 22.69% compared to the panel without the cooling system.
2
Content available remote Wykorzystanie ciepła odpadowego w procesie skojarzonego wytwarzania energii
PL
W pracy przedstawiono analizę możliwości zastosowania absorpcyjnych pomp ciepła (APC) do zwiększenia efektywności wykorzystania energii pierwotnej w bloku parowym elektrociepłowni zawodowej poprzez odzysk ciepła odpadowego z układu chłodzenia oleju. W analizowanym przykładzie zastosowanie APC służyło ograniczeniu liczby uruchomień szczytowych kotłów wodnych. Uzyskane wyniki potwierdziły, że istnieje możliwość wykorzystania ciepła odpadowego w okresie największego zapotrzebowania i tym samym możliwość opóźnienia lub nawet wyeliminowania konieczności uruchamiania szczytowego źródła ciepła.
EN
The paper shows the analysis of potential of absorption heat pump (APC) application to increase the efficiency of source energy conversion in the cogeneration power plant, by recuperation of waste heat from oil cooling system. In the presented case, the purpose of APC implementation was to eliminate the number of start up of pick hot water boilers. Obtained results showed that the waste heat may be utilised during the highest heat demand which may lead to delay or even avoiding the pick boiler start up, owing to absorption heat pump implementation.
EN
The amount of currently generated wastes originating from different branches of industry, in accordance with the requirements of the applicable national legislation, shall be successively reduced. The properly made analysis of the possibilities for reusing wastes generated during the course of the production cycle, coupled simultaneously with the analysis of the generated waste management procedures, provides a real possibility of reducing their quantities, which may additionally be significantly reflected in the reduction of the enterprise running costs. Upon implementing new technologies for handling the generated wastes – as a recognized by-product – the appropriate waste management method may contribute to the improvement of the plant's viability and profit. The implementation of new activities and procedures concerning the organization of the waste handling method, planned to this end, should be coupled with the simultaneous review and analysis of available technologies that assure the utilization of the waste as a by-product, directly at its source. In the light of the foregoing, the knowledge of the main factors having an effect on the increase in waste management efficiency, while taking account of the applicable environmental requirements and standards, becomes a basis for achieving the ecological effect and the resultant financial effect.
PL
Ilość wytarzanych obecnie odpadów pochodzących z różnych gałęzi przemysłu zgodnie z wymogami obowiązującego prawa krajowego w tej materii winna być sukcesywnie ograniczana. Odpowiednio przeprowadzona analiza możliwości dalszego wykorzystania powstających w trakcie cyklu produkcyjnego odpadów, połączona jednocześnie z analizą procedur zarządzania wytwarzanymi odpadami daje realną możliwość ograniczenia ich ilości, co dodatkowo w sposób znaczący może znaleźć odzwierciedlenie w obniżeniu kosztów funkcjonowania przedsiębiorstwa. Po wprowadzeniu nowych technologii w zakresie postępowania z wytwarzanymi odpadami jako uznanym produktem ubocznym, odpowiedni sposób gospodarki odpadowej może przyczynić się do poprawy wzrostu rentowności i zysku zakładu. Planowane w tym celu wdrożenie przez zakład nowych działań i procedur dotyczących organizacji sposobu postępowania z odpadami, winno być połączone z jednoczesnym przeglądem i analizą dostępnych technologii gwarantujących wykorzystanie odpadu jako produktu ubocznego bezpośrednio w miejscu jego powstawania. W świetle powyższego znajomość głównych czynników mających wpływ na wzrost efektywności gospodarowania odpadami przy jednoczesnym uwzględnieniu obowiązujących wymogów i norm środowiskowych, staje się podstawą osiągnięcia efektu ekologicznego i wynikającego z niego efektu finansowego.
PL
W artykule przedstawiono wpływ zastosowania upustu na sprawność turbiny gazowej. Upust w turbinie zrea-lizowano według idei prof. Roberta Szewalskiego, która polega na zastosowaniu upustu międzystopniowego w turbinie gazowej do podgrzewu powietrza zasilającego komorę spalania. Dzięki przeprowadzonej modyfikacji osiąga się wzrost sprawności obiegu oraz spadek zużycia paliwa. Analiza numeryczna obiegu cieplnego przed i po modernizacji została przeprowadzona za pomocą kodów CFM. Obiegiem wyjściowym dla przeprowadzonych obliczeń jest blok gazowo - parowy w Gorzowie Wielkopolskim.
EN
The modernization of the GT8C gas turbine into Szewalski cycle has been presented in the paper. The Szewalski idea is based on the exhaust gases extraction from gas turbine for air preheating before it enters the combustion chamber. The extracted gas transfers heat to air via the regenerative heat exchanger. Such modification leads to the cycle efficiency increase. Simultaneously amount of fuel burned in the combustion chamber decrease. The numerical analysis of thermal cycles, before and after the modification, has been carried out by means of an in-house COM-GAS code and Aspen Plus commercial package. Thermodynamic analysis has been performed assuming parameters characteristic for PGE Gorzow combined power plant.
PL
W referacie przedstawiono analizę możliwości modernizacji istniejącego bloku parowego w celu polepszenia efektywności pracy. Analizowano dwa podstawowe warianty modernizacji. Pierwszy z nich polega na podniesieniu temperatury pary świeżej. Taki zabieg pociąga za sobą wymianę przegrzewacza pary. Ostatnia część musi być wykonana z materiałów zdolnych do pracy w podwyższonej temperaturze. Warianty proponowane w tym zakresie uwzględniają przebudowę istniejącego kotła, bądź dostawienie oddzielnego kotła gazowego. Modernizacja obejmuje także wymianę części wysokoprężnej turbiny na nową. Opisywane rozwiązanie wymaga także szczegółowej analizy warunków eksploatacji przegrzewacza wtórnego ze względu na zmienioną temperaturę pary na wylocie z części wysokoprężnej turbiny. Z tego względu w badaniach modelowano pracę całego obiegu parowego, obejmującego m. in. kocioł wraz z przegrzewaczem oraz część wysokoprężną turbiny z układem regeneracji. Badania obejmowały zwiększenie temperatury pary świeżej w zakresie 600 - 700oC. Drugi wariant modernizacji polega na podwyższeniu temperatury pary wtórnej przy pozostawieniu temperatury pary świeżej na dotychczasowym poziomie. Takie podejście wymaga wymiany części średnioprężnej turbiny oraz modernizacji przegrzewacza wtórnego, albo w ramach istniejącego rozwiązania konstrukcyjnego, albo poprzez dostawienie kotła gazowego. Temperatura pary w tym przypadku może sięgać 620 - 720oC.
EN
This paper presents a feasibility study of a modernization of an existing power generating unit aimed to improve its performance. Two basic modernization options are under investigation. The idea behind the first one is a live steam temperature increase. Such modification requires a superheater upgrade. The piping in the hottest section must be made of materials able to resist high temperature. The solutions provided for this option assume a reconstruction of the steam boiler or an addition of a separate gas boiler. The modernization involves also the exchange of the high pressure part of a turbine. The solution described above requires also a detailed analysis of the operating conditions of the reheater, due to the altered temperature at the outlet of the new HP turbine part. Therefore the modeling within the framework of the study involved the whole steam cycle, together with the boiler and the reheater, the HP turbine part and the heat regeneration system. The research analyzed the live steam temperature changes in the range 600-700oC. The concept of the second modernization option is to increase the reheat steam temperature, while the live steam temperature remains unchanged. Such approach requires the exchange of the intermediate turbine part and the reconstruction of the reheat superheater either within the existing design or through the addition of a gas boiler. The reheat steam temperature may vary between 620 and 720oC.
EN
This paper presents cases, when the development of clean coal power depends on new materials. Current state-of-the-art, existing constraints and possible directions of further development are presented. Modern power plant should have: a) high efficiency, b) the possibility of simple and cheap CO2 capture. Efficiency increase can be achieved in a few ways as: further increase of thermodynamic parameters of steam cycle, introduction of gas turbine on gasified coal, reduction of loses connected with unavoidable temperature shifts through high temperature heat exchanger application or Solid Oxide Fuel Cell introduction. Currently, CO2 is captured with amine solutions from casual flue gas containing ~80% of nitrogen. There are ideas to redesign the power plant to avoid mixing of combustion products with atmospheric nitrogen and to use gas separating membranes and chemical loops instead of amines.
PL
Artykuł przedstawia wyniki badań dotyczące nowoczesnych bloków parowych na parametry nadkrytyczne. Zastosowanie pary o podwyższonych parametrach znakomicie zwiększa sprawność wytwarzania energii elektrycznej, co sprawia, iż nadkrytyczne bloki parowe stanowią istotną opcję na rynku energii. Równocześnie zastosowanie nadkrytycznych parametrów pary wiąże się z szeregiem problemów, nie występujących w przypadku konwencjonalnych turbin. Jednym z nich jest optymalne wykorzystanie właściwości materiałów stosowanych w budowie turbin. Ponieważ nowe materiały mogą pracować w znacznie podwyższonej temperaturze, zatem celowe staje się wykorzystanie w pełni tej możliwości. W pracy analizowano zagadnienie podniesienia parametrów pary świeżej z uwzględnieniem ograniczeń materiałowych w celu zapewnienia jak najlepszych osiągów pracy bloku energetycznego.
EN
The paper presents research results, which concern modern supercritical power generating units. The application of live steam at the increased pressure and temperature significantly boosts the power generation efficiency, which establishes supercritical steam units as a noteworthy option at the power industry market. Nevertheless the supercritical live steam parameters are related to a number of problems, which do not occur in conventional steam turbines. One of them is the optimal application of the materials according to their properties. Since the new materials may operate under substantially higher temperature levels, then it is advisable to take full advantage of this property. The research presented here concerns the problem of live steam temperature increase with respect to the material properties constraints in order to boost the power cycle efficiency.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.