Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 2

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  efekt chłodzenia
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
Thermoelectric modules (TE), also called Peltier modules, can be used for the cooling processes in various system configurations. The thermoelectric modules act as a heat pump - supplying electrical energy to the TE module causes energy transport from its one side, called the cold side, to the other one, called the hot side. The effects of the Peltier module operation depend on the applied heat exchangers type and the intensity of the current supplied to the module. In this paper, the operation of a selected thermoelectric module used for cooling experimental room of a 0.125 m3 is presented. The heat exchangers, consisting of aluminum radiators integrated with fans, were used to improve the heat exchange process on both sides of the applied TE module. During the tests, the temperature changes inside the experimental room and on the heat sinks on the cold and the hot sides of the TE module at variable current supply from 4 to 6 A were followed. The best results of cooling performance were obtained with 4 and 5 A currents. In these cases, the temperature inside the experimental room was reduced by approx. 9 °C.
PL
Ogniwa termoelektryczne, zwane również ogniwami Peltiera, mogą być wykorzystywane do procesu chłodzenia w różnych rozwiązaniach konfiguracyjnych. Ogniwa termoelektryczne działają jak pompa ciepła dostarczenie energii do ogniwa powoduje, że energią z jego jeden strony, zwanej stroną zimną, jest pobierana i transportowana na drugą, zwaną stroną gorącą. Efekty działania ogniwa Peltiera zależą od zastosowanych wymienników ciepła oraz od natężenia prądu zasilającego ogniowo. W pracy przedstawiono działanie wybranego ogniwa termoelektrycznego wykorzystanego do chłodzenia komory badawczej o kubaturze 0,125 m3. Po obu stronach ogniwa zastosowano wymienniki składające się z radiatorów aluminiowych i wentylatorów w celu usprawnienia procesu wymiany ciepła. Podczas trwania badań śledzono zmianę temperatury wewnątrz komory badawczej, na radiatorze po stronie zimnej oraz na radiatorze po stronie gorącej ogniwa termoelektrycznego przy zmiennym natężeniu prądu zasilającego wynoszącym od 4 do 8 A. Najlepsze efekty chłodzenia otrzymano przy natężeniach prądu 4 i 5 A. W tych przypadkach udało się obniżyć temperaturę wewnątrz komory badawczej o ok. 8 °C. W przypadku zasilenia ogniwa prądem o natężeniu 8 A doszło do ogrzania komory badawczej o ponad 5 °C.
EN
Active development of modern cities has led to the problem of shortage of land, especially in the central urban areas. This has created serious environmental problems that can be solved with the help of roof greening. The work carried out to test the hypothesis of “cooling effect” vegetable green roof layer. Our experimental studies suggest that the “cooling effect grass” due to the evaporation of moisture during temperature measurement. We have identified the main thermal processes occurring in the top layer of the roof: the reflection and absorption of solar radiation, the thermal resistance between the soil and the surrounding air by conduction and convection, accumulation of heat in the soil, moisture exchange between the soil, the grass and the environment. Reducing the temperature of the grass compared to bituminous coating due to the decrease of the absorption of solar energy. Low soil temperature as compared with ambient air connected with the insulating properties of grass that saves “cold” accumulated during the night by ground.
PL
Aktywny rozwój nowoczesnych miast generuje problem niedoboru ziemi i zieleni w szczególności w centralnych obszarach miejskich. To stało się przyczyną poważnych problemów środowiskowych, które mogą być rozwiązane za pomocą ogrodów dachowych. Prace przeprowadzono w celu przetestowania hipotezy „efekt chłodzenia” roślinnej warstwy dachu. Nasze badania wskazały „efekt chłodzenia” w rezultacie odparowania wilgoci przy pomiarach temperatury. Zidentyfikowano procesy termiczne zachodzące w warstwie wierzchniej dachu: zjawiska odbicia i absorpcji promieniowania słonecznego, opór przejmowania ciepła na powierzchni dachu uwzględniający przewodzenie i konwekcję ciepła, akumulację ciepła w gruncie, wymianę wilgoci między gruntem, warstwą roślinną i powietrzem. Obniżenie temperatury pokrywy trawiastej w porównaniu do powłok bitumicznych spowodowane jest obniżeniem absorpcji energii promieniowania słonecznego. Niższa, w porównaniu do temperatury powietrza, temperatura gruntu wynika z właściwości zatrzymania w gruncie „chłodu” powstałego w okresie nocnym.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.