Power System stability is an essential study in the planning and operation of an efficient, economic, reliable and secure electric power system because it encompasses all the facet of power systems operations, from planning, to conceptual design stages of the project as well as during the systems operating life span. This paper presents different scenario of power system stability studies on a modified IEEE 30-bus system which is subjected to different faults conditions. A scenario whereby the longest high voltage alternating current (HVAC) line is replaced with a high voltage direct current (HVDC) line was implemented. The results obtained show that the HVDC line enhances system stability more compared to the contemporary HVAC line. Dynamic analysis using RMS simulation tool was used on DigSILENT PowerFactory.
2
Dostęp do pełnego tekstu na zewnętrznej witrynie WWW
This paper presents an overview on the effect of grid-connected photovoltaic (PV) system on static and dynamic voltage stability and discusses the analysis techniques used to quantify the effect. A review on the published works showed that the PV system design, PV parameters and the distinct design of power system network affect system voltage stability. Furthermore, a discussion is also made on the optimization techniques used for determining optimum PV placement and sizing for the purpose of improving voltage stability.
PL
W artykule dokonano przeglądu metod analizy wpływu dołączenia systemu fotowoltaicznego na właściwości statyczne i dynamiczne sieci. Odpowiedni projekt wpływa na stabilność napięciową. Analizowano też metody optymalizacji położenia systemu.
3
Dostęp do pełnego tekstu na zewnętrznej witrynie WWW
Nowadays, the large penetration of wind power generation poses new challenges for the dynamic voltage stability analysis of an electric power system. In this paper is studied the influence of the reactive power management for wind power plants in the dynamic voltage stability of an electric power network under a fault condition, considering two different Doubly-Fed Induction Generators (DFIG) models. The simulation results were obtained using the EUROSTAG software package.
PL
W artykule przedstawiono wpływ zarządzania mocą bierną w elektrowniach wiatrowych na stabilność dynamiczną napięcia w sieci elektrycznej. Zbadano przypadek dwóch różnych modeli generator.
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.