Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 12

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  dust pollution
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
The condition of air quality depends on many external (the amount of pollutant emissions, intensity and type of physico-chemical changes taking place in the atmosphere and large-scale movement of air pollutant masses) as well as internal factors (such as finishing materials, room equipment, heating systems, ventilation systems, and the presence of the humans themselves). As a result, there are various risks related to air quality, including the most important ones related to microbial contamination. For this reason, it was decided to analyze the quality of internal air in terms of microbiological contamination that may occur in university lecture halls with mechanical supply and exhaust ventilation. The analysis also took into account the impact of mechanical ventilation on physical parameters such as temperature, relative humidity as well as the concentration of PM10 and PM2.5 particulate matter pollutants, thus determining the impact of the tested parameters on human health and well-being. All the obtained results were compared with the applicable permissible standards and conclusions were drawn regarding the improvement of the quality of the indoor air microclimate.
PL
W wyniku pozyskiwania i przetwarzania surowców kopalnych dochodzi do niekontrolowanej emisji pyłów do atmosfery, a pył osadzający się na pokrywie śnieżnej jest cennym źródłem informacji o źródle zanieczyszczenia powietrza. Badania prowadzono na obszarze podlegającym silnej presji antropogenicznej w południowo-wschodniej części Padołu Kielecko-Łagowskiego. Pobrano 13 próbek śniegu z obszaru o powierzchni 600 ha położonego w rejonie górniczym (wydobycie skał węglanowych) i zbadano je pod kątem pH, przewodnictwa elektrolitycznego oraz zawartości jonów Cl⁻, Ca²⁺, NO₃⁻ i SO₄²⁻. W ciągu 2 tygodni występowania pokrywy śnieżnej kilkakrotnie wzrosła zawartość badanych jonów oraz pH i przewodnictwo elektrolityczne.
EN
Thirteen snow samples were collected from an area of 600 ha located in the mining district of carbonate rocks and studied for pH, electrolytic cond. and content of Cl, Ca, NO₃ and SO₄ ions. The value of the studied parameters increased several times during the 2 weeks of the presence of snow cover. The dust deposited on the snow cover was a valuable source of information about the air pollution.
PL
Omówiono jakość powietrza w Polsce (z zaznaczeniem jego jakości w Europie) oraz przedstawiono przykłady wykorzystania bezzałogowych statków powietrznych do oceny stanu zanieczyszczenia powietrza. Opisano systemy pomiarowe wykorzystujące sensory, które służą do pomiaru parametrów niskiej emisji pyłów oraz gazów zawieszonych w powietrzu. Scharakteryzowano również metody pomiaru pośredniego polegającego na pobieraniu próbek powietrza i dostarczaniu ich do laboratorium.
EN
A review, with 23 refs., of air quality in Poland and use of unmanned aerial vehicles in assessing emissions of dust and gases suspended in the air.
EN
This work covers the pollution of the atmosphere during the work of the Mikhailovsky Mining and Refining Facility which is located within 100 km from the city of Kursk, in the city of Zheleznogorsk. Over the past few years in the whole world, the anthropogenic activity, connected mainly with the locations of mineral production and those of mineral treatment and processing, has become increasingly dangerous for the natural environment. Resource development in open pits causes the formation of inorganic dust. The dust is released into the atmosphere at all stages of the enterprise’s technical process. The principal sources generating inorganic dust during open mining of iron deposits include: blasting operations in an open pit, the work of transfer points, the enrichment process at a factory, pellet firing as well as dusting from the surfaces of stock dumps and dry tailings beaches.
EN
The issue of indoor air quality is becoming increasingly important. Ensuring optimal air parameters is important for the health of people who are particularly sensitive to impurities contained therein. Finding solutions that improve the quality of indoor air requires a prior detailed recognition of the problem of its pollution. The subject of the research is dust pollution in the air in a teaching laboratory room. The attention was focused on the characteristics of air pollution with the total dust fraction and suspended particulate fractions PM10 and PM2.5. The dust content was measured with a laser meter enabling indirect measurement. It consists in using the phenomenon of damping laser light scattered on the tested air sample at an angle of 90 degrees. As a result of the conducted research, factors influencing the increase of dust concentration in the indoor air were identified. These include the quality of the outdoor air and the source of dust emission in the room. In order to obtain more comprehensive data, it is necessary to continue the research with the possibility of extending the duration of the measurement tests and the test cycle.
PL
W artykule przedstawiono problem związany z zanieczyszczeniem powietrza pyłem zawieszonym PM10 oraz PM 2,5 w aglomeracjach miejskich. Podstawowymi źródłami zanieczyszczeń gazowych i pyłowych powietrza na obszarach miejskich są emisje pochodzące z sektora komunalno – bytowego, środków transportu i przemysłu. Opisano strukturę transportu w Polsce oraz udział pojazdów samochodowych w zanieczyszczeniu powietrza. Przedstawione zostały wyniki badań z pojazdów samochodowych, które wykonano w stacji kontroli pojazdów.
EN
This article presents the problem of PM10 and PM 2.5 dust pollution in urban agglomerations. The main sources of gaseous and particulate pollutants in urban areas are emissions from the transport sector, means of transport and industry. The structure of transport in Poland and the share of motor vehicles in air pollution are described. The results of tests from motor vehicles made at the vehicle inspection station are presented.
PL
Budynki Lipsk, Berlin są przykładami konstrukcji zawierających materiały z azbestem tzw. „słabo zwięzłe” i „zwięzłe” wbudowane do wnętrza obiektów i stanowiącymi wewnątrz nich zagrożenie zanieczyszczeniem powietrza pyłem azbestowym .Sama obecność tych wyrobów nie jest jednoznaczna z zanieczyszczeniem powietrza. Jego wystąpienie i poziom zależą od wielu czynników. Zwyczajna eksploatacja tych budynków nie musi stanowić zagrożenia. Jednak zły stan techniczny może spowodować duże zanieczyszczeniem. Jeszcze większe jego ryzyko może powodować proces usuwania azbestu.
EN
Buildings Lipsk, Berlin are examples of structures containing materials with so-called asbestos "friable" and "non-friable" built in into the interior of objects and posing a threat of the air pollution of asbestos dust inside them. Very presence of these products isn't tantamount to the air pollution. His address and the level depend on many factors. The normal use of these buildings not has to pose a threat. However the bad technical condition can cause the great pollution. Even bigger his risk can cause the process of removing asbestos.
PL
W artykule przedstawiono zagadnienie mikroklimatu i zapylenia, jako czynników towarzyszacych na stanowiskach pracy. Wykonano pilotowe badania ww. czynników na terenie obiektów naftowych, celem uzyskania danych do opracowania programu komputerowego w postaci zestawu skoroszytów - arkuszy kalkulacyjnych EXCEL, który w stosunkowo krótkim czasie pozwala dokonać oceny wyników badań zapylenia i mikroklimatu w środowisku oraz na stanowiskach pracy. Program spełnia wymagania europejskie i jest na bieżąco użytkowany przy ocenach zagrożeń wymienionych czynników w zakładach górniczych przemysłu naftowego oraz branż pokrewnych.
EN
This publication presents the microclimate and dust pollution impact on the workplace. Pilot tests of microclimate and dust were performed on oil mine objects in order to get data that will be useful in creating EXCEL spreadsheets permitting, in relatively short time, to estimate measurement results of dust pollution and microclimate in the environment and in the workplace. This program fulfills European requirements and it is currently used to assess hazards created by above mentioned factors in oil mining plants and in similar industries.
PL
W artykule przedstawiono założenia metody oceny emisji substancji przenoszonych powietrzem z maszyn zgodnie z zaleceniami PN-EN 1093-2. W normie tej określono sposoby postępowania podczas wyznaczania wielkości emisji zanieczyszczeń z maszyny, w określonych warunkach pracy maszyny, z zastosowaniem metody znaczników gazowych. Zasadą metody pomiarów jest generowanie znacznika gazowego ze znanym i stałym strumieniem, symulującym aerodynamiczne zachowanie się rzeczywistego zanieczyszczenia, a następnie na prowadzeniu pomiarów stężenia znacznika gazowego i rzeczywistego zanieczyszczenia w otoczeniu źródła emisji.
EN
This article presents a method of determining emission of airborne pollutants by machines. It complies with Standard No. PN-EN 1093-2. This standard describes a method of measuring emission rates of airborne pollutants from a single machine, whose operation can be controlled, using tracer gas techniques. The principle is based on the use of a tracer gas generated at a known and constant emission rate to provide the best representation of the pollutant source. Mean tracer gas and pollutant concentrations are measured in the vicinity of the source.
PL
W artykule przedstawiono wyniki degradacji modelowych izolatorów kompozytowych badanych w wysokonapięciowej komorze mgielnej. Opisano wpływ pyłowych zabrudzeń na utratę hydrofobowych właściwości powierzchni izolatorów i na prąd upływu. Wskazano na możliwość oddziaływania warstwy zabrudzeń na spowolnienie tempa utraty hydrofobowych właściwości powierzchni. Podkreślono pozytywny wpływ zwiększenia wartości kąta nachylenia górnych powierzchni kloszy na wzrost odporności izolatorów na starzenie.
EN
In this paper results of ageing degradation of non-ceramic model insulators tested in high voltage fog chamber are presented. Influence of dust pollution on insulator’s surface hydrophobic property loses and leakage current are described. It was indicated that the presence of pollution layer influences the slowing down of non-ceramic insulators hydrophobic properties losing. Positive influences of increase of upper surface sheds inclination on ageing process resistance of insulators are emphasized.
11
Content available remote Usuwanie zanieczyszczeń osadzonych w przewodach wentylacyjnych
PL
W artykule przestawiono najczęściej stosowane metody oczyszczania przewodów wentylacyjnych. Omówiono dwa sposoby usuwania zanieczyszczeń pyłowych; mechaniczne czyszczenie za pomocą szczotek obrotowych oraz czyszczenie za pomocą powietrza sprężonego dostarczanego przez dysze. Opisano także zastosowanie dysz do napryskiwania na wewnętrzną powierzchnię przewodów wentylacyjnych preparatów biobójczych, tzw. biocydów, zwalczających namnożone wewnątrz instalacji kolonie grzybów oraz bakterii.
EN
The most often applied methods for cleaning the ventilation duels were presented in the article. Two procedures of dust removing were described: mechanical cleaning with the help of rotational brushes and cleaning with the help of compressed air supplied through nozzles. The application of nozzles for splashing the bio preparations, so called biocides on the inner surface of ventilation ducts fighting with fungus colony and bacteria multiplying inside the system, was also described.
PL
Odlewnie żeliwa mogą stanowić zagrożenie dla środowiska związane zarówno z emisją zanieczyszczeń pyłowo-gazowych jak i z wytwarzaniem odpadów. W artykule zamieszczono dane dotyczące wielkości emisji zanieczyszczeń pyłowo-gazowych (SO" NO,. CO, CO, i pyl Ów) oraz ilości, składu chemicznego i wymywalności odpadów odlewniczych wytwarzanych w różnych etapach procesu technologicznego (zużytych mas odlewniczych, żużli metalurgicznych i pyłów z odpylania pieców topielnych). Dane pochodzą z 20 krajowych odlewni o różnej wielkości, w których były produkowane głównie odlewy żeliwne. Zagadnienie to jest bardzo ważne z tego względu że produkcja odlewów żeliwnych w Polsce stanowi ponad 90% wszystkich odlewów ze stopów żelaza (w 1995 roku wyprodukowano 830 ODO Mg odlewów ze stopów żelaza w tym 725 000 Mg odlewów żeliwnych).
EN
Iron foundries might be dangerous for the environment not only as a source of gas and dust pollution, but also as waste source. In the article data concerning the level of gas and dust pollution emission (S02, NOx, CO, CO2, and dusts), amounts, chemical constitution and leaching of foundry wastes (used moulding sand, slugs and dusts from melting furnaces) from different stages of technological process has been given. The data come from 20 national foundries of different size which main product was cast iron. The issue is very important as 90% all foundry products in Poland fall to cast iron (in 1995 out of 830 000 tons of foundry products 725 000 tons were cast iron).
first rewind previous Strona / 1 next fast forward last