The paper presents the results related to the simulation of dust-separating tangential cyclones: single cyclones of various geometries, and an axial multi-cyclone with fixed geometries and components. Its goal was to apply low-cost analyses for cyclones in industrial realization. Therefore, the presented research was applied with simulation methodology as a problem of Computational Fluid Dynamics. The models were analyzed using SolidWorks Flow Simulation software. The presented dust collectors are real-life objects, applied in industrial facilities. For a multi-cyclone, the increase in the number of blades, from 5 to 8, together with the change in the angle of a blade’s pitch i.e., 30° and 45°, resulted in dust concentration along the internal walls from just 10% for 5 blades up to c.a. 37.5% for 6 blades, and c.a. 50% for 8 blades, whereas the dust concentration in the device’s central part equals c.a. 20% for the last option. The model validation draws attention to the potential applicability of the software in flow issues alongside common and more complex numerical environments.
PL
W artykule przeprowadzono analizę stosowanych przenośników w systemach odbioru i transportu pyłu z kotłów z paleniskiem rusztowym w energetyce przemysłowej i ciepłowniczej. Zwrócono uwagę na konstrukcję najczęściej stosowanych rodzajów przenośników, ich parametry konstrukcyjne i eksploatacyjne. Dokonano oceny porównawczej zużycia energii elektrycznej do napędu urządzeń. Przeprowadzona analiza może być pomocna przy podejmowaniu decyzji techniczno-finansowych w ww. zakresie.
EN
This paper analyzes the conveyors used in dust collection and transport systems from grate boilers in industrial and heating energy. Attention was paid to the construction of the most commonly used types of dust conveyors, their construction and operational parameters. A comparative assessment was made of electricity consumption for the drive of the equipment. The analysis helps in making technical and financial decisions.
EN
A modification of the structure of the dust collector has been made through partitioning of its chamber into separate dedusting channels to which a number of cyclones was assigned. Using the model of the dust collector a preliminary selection of the heights h1, h2, .... hi, at the intake was made of the individual channels of the dust collector sections to ensure identical flow resistance of the airstream through these channels. The model investigations of the sections of the dust collector were verified in flow investigations. The values of the stream was measured extracted from individual cyclones for several variants of the dust collector. An assessment of the improvement of the dedusting efficiency from individual cyclones has been performed.
PL
W artykule opisano zmianę formy konstrukcyjnej osadnika pyłu przez podział komory osadnika pyłu na odizolowane od siebie kanały odsysania, którym przyporządkowano określoną liczbę cyklonów. Wykorzystując model osadnika pyłu, dokonano wstępnego doboru wysokości na wylocie h1, h2, .... hi, kolejnych kanałów odsysających segmentu osadnika pyłu pod względem jednakowych oporów przepływu strumieni powietrza przez kanały. Badania modelowe segmentu osadnika pyłu zweryfikowano podczas badań przepływowych. Pomierzono wartości strumieni powietrza odsysanego z pojedynczych cyklonów dla kilku wariantów osadnika pyłu. Dokonano oceny poprawy równomierności odsysania pyłu z pojedynczych cyklonów multicyklonu filtru powietrza.
EN
The factors hierarchy performance model for a new design dust collector is developed. In addition to ordering the factors by importance of their influence, this model allows further separation of dependent (internal) components to identify the degree of weakening or strengthening of the source factor.
EN
The paper presents a possible improvement of uniformity of dust extraction from individual cyclones of a multi-cyclone air filter with modifications of the dust collector design. The suggested dust collector model is divided into segments, with insulated extraction ducts, assigned to a specific number of individual cyclones. The concept of the division into extraction ducts and segments is presented based on the air filter multi-cyclone of a special tracked vehicle. A physical and mathematical model of the dust collector segment is presented, and the heights of individual extraction ducts are calculated.
PL
W artykule przedstawiono możliwość poprawy równomierności odsysania pyłu z pojedynczych cyklonów multicyklonowego filtra powietrza, polegającą na zmianie formy konstrukcyjnej osadnika pyłu. Zaproponowano model osadnika pyłu podzielonego na segmenty mające odizolowane od siebie kanały odsysania, którym przyporządkowano określoną liczbę cyklonów. Ideę podziału na segmenty i kanały odsysania przedstawiono na przykładzie multicyklonu filtra powietrza gąsienicowego pojazdu specjalnego, Przedstawiono model fizyczny i matematyczny konstrukcji segmentu osadnika pyłu. Wykonano obliczenia wysokości kanałów odsysania.
6
Content available remote Nowe rozwiązania aparaturowe w procesach ochrony środowiska
PL
Przedstawiono wyniki wybranych prac badawczych, wykonanych w Katedrze Aparatury Chemicznej i Procesowej Politechniki Śląskiej, ukierunkowanych na intensyfikację procesów separacji i wymiany masy, związanych z ochroną środowiska. Część tych prac znajduje się w fazie zakończonych badań procesowych, potwierdzających oczekiwane efekty a część doczekała się licznych wdrożeń przemysłowych.
EN
A review of Authors’ works covering designed and implemented units like dust collectors, a lamella settler, a controlled-gap plate column, and a pneumatic reactor used to desulfurize flue gases.
PL
Opisano możliwość wykorzystania elektronowego mikroskopu skaningowego oraz rentgenowskiego mikroanalizatora EDS w badaniach pyłów, emitowanych z procesów odlewniczych, w szczególności do oceny składu chemicznego pyłu w próbkach, pobranych ze strumienia zanieczyszczeń emitowanych do powietrza atmosferycznego przez żeliwiak, zanieczyszczeń powietrza na stanowiskach pracy w odlewni oraz składu chemicznego i kształtu ziarn pyłu w celu właściwego doboru parametrów pracy i zastosowanych materiałów konstrukcyjnych odpylacza.
EN
The possibility of utilizing a scanning electron microscope and an X-ray microanalyzer EDS when investigating dust emission from foundry processes is discussed. They can be used to evaluate chemical composition and shape of dust particles in samples taken from a stream of impurities emitted by cupola to atmospheric air and air pollutants at work stands in foundries to verify the work parameters and design of dust collectors of proper yield.