Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 11

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  durability assessment
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
Diagnostics of existing buildings includes, among others research to assess their durability. In the case of reinforced concrete structures, such tests include semi-destructive electrochemical tests to forecast the corrosion risk of steel bars in concrete, and one of the methods used is the electrochemical, polarizing galvanostatic pulse method. The aim of the article was to recognize the influence of element effort on the measurement results obtained with this method. For the tests, a reinforced concrete cantilever slab loaded monotonically was used. During the tests, the stationary potential and corrosion current density of the main reinforcement bars, as well as the resistivity of the concrete cover, were measured. Based on the results obtained, it was found that the level of effort on the element affects the values of the measurements performed. Differences in the values of measured parameters at different levels of element effort are sometimes so large that they may significantly affect the conclusions about the corrosion risk of the tested reinforcement, and thus incorrectly estimate the durability of the tested element.
2
Content available remote Wymagania dotyczące trwałości zabezpieczeń ogniochronnych
PL
W artykule zestawiono obowiązujące dokumenty odniesienia dotyczące dużej grupy wyrobów stosowanych do zabezpieczeń ogniochronnych konstrukcji budowlanych, ścian oraz posadzek. Przedstawiono wymagany okres trwałości tych wyrobów, w tym stałość parametrów użytkowych deklarowanych przez producentów. Opisano przykładowe badania symulujące warunki użytkowe w środowisku X, Y, Z1, Z2 w kontekście zapraw tynkarskich i powłok reaktywnych. Zaprezentowano wymagania zawarte w dokumentach EAD dotyczące oceny trwałości wyrobów po działaniu tych środowisk.
EN
The article summarizes the applicable reference documents for a wide group of products used for fire protection on building structures, walls and floors. The required durability periods for these products were presented, including the stability of the performance parameters declared by the manufacturers. Exemplary tests simulating operating conditions in environments such as X, Y, Z1, Z2 in the context of plastering mortars and reactive coatings have been described. The requirements set by the EAD documents in the scope of the assessment of the durability of products after exposure to these environments have been presented.
EN
This article presents different types of commercially available roof waterproofing membrane systems used on roofs with large surface area. It deals with the causes of deterioration of such membranes due to environmental factors and describes the tests used to detect leaks and determination of the severity of deterioration of polymeric membranes taking into account the properties declared by their manufactures. The last part of the article is a case study comparing a brand new membrane with a membrane after 27 years in service.
4
Content available remote Structural health monitoring system of a concrete cable-stayed bridge
EN
In this paper a system of the Rędziński bridge will be described. The Rędziński bridge is the biggest object along the A8 motorway around the city of Wrocław and the biggest concrete cable-stayed bridge in Poland. For the purposes of the bridge monitoring a system of 222 sensors was installed. Results from the first 5 years of work of the SHM will be presented below.
PL
Artykuł zawiera modelowe obrazy degradacji mikrostruktury stali 16Mo3 pracującej w warunkach pełzania w części ciśnieniowej kotła energetycznego. Dla badanego materiału podano klasy struktury w zależności od stanu jej mikrostruktury w tym również stopnia rozwoju procesów wydzieleniowych w powiązaniu ze stopniem wyczerpania. W postaci graficznej przedstawiono odniesienie klas mikrostruktury do stopnia wyczerpania, dokonane na podstawie oceny zmian w strukturze to jest: stopnia rozpadu poszczególnych faz, stopnia rozwoju procesów wydzieleniowych oraz stopnia rozwoju wewnętrznych uszkodzeń. W tabelach zestawiono zaproponowane okresy dopuszczenia do dalszej eksploatacji w zależności od klasy struktury i odpowiadającego jej stopnia wyczerpania.
EN
The article contains the model images of the degradation of 16Mo3 steel microstructure working in creep conditions of pressure zone in the boiler. The material being tested is given class structure according to the state of the microstructure, including: the degree of development of the processes of precipitation in relation to the degree of exhaustion. In graphical form shows the microstructure of a reference class to the degree of exhaustion, made on the basis of changes in the structure of it is: the degree of disintegration of the individual phases and level of precipitation processes and the degree of development of internal damage. The tables summarize the proposed periods of admission to further exploitation depending on the class structure and the corresponding degree of exhaustion.
6
Content available remote Problemy z oceną i deklarowaniem trwałości zapraw do murów
PL
Obecnie do oceny mrozoodporności zapraw murarskich i tynkarskich w Polsce stosuje się wycofaną normę PN-85/B-04500, jednakże wydaje się, że sposób postępowania przy przygotowaniu próbek do badań powinien ulec modyfikacji. Podczas badań trwałości zapraw do murów zauważono, że niejednokrotnie sposób przygotowania próbek do badań może wpływać na uzyskane wyniki mrozoodporności zapraw. Problem ten dotyczy zarówno przygotowania w odpowiednich formach, zagęszczania, sezonowania oraz suszenia próbek do badań. Wielokrotnie w praktyce laboratoryjnej okazywało się, że próbki ulegały zniszczeniu przed poddaniem ich cyklom zamrażania-rozmrażania. W niniejszym artykule przedstawiono wyniki badań mrozoodporności próbek zapraw przygotowanych i sezonowanych wg różnych wariantów.
EN
Currently in Poland for assessment of the freeze-thaw resistance of the masonry and plastering mortars still withdrawn PN-85/B-04500 standard is applied. However, it seems that the proceeding during the preparation of the samples should be modified. In this connection, the durability tests were conducted. It has been noticed that the way of the sample preparation can clearly affect the obtained freeze – thaw mortar resistance results. It is complex issue related to sample preparation in the appropriated moulds, curing and drying processes as well. Repeatedly in laboratory practice it turns out that durability of the samples deteriorates even before taking proceeding of the freeze-thaw cycling. In this study the results of the freeze-thaw mortar resistance test are covered. The mortar samples were prepared and cured according to different approaches.
7
Content available Ocena trwałości zapraw do murów
PL
Obecnie do oceny mrozoodporności zapraw murarskich i tynkarskich w Polsce stosuje się wycofaną normę PN-85/B-04500, jednak wydaje się, że sposób postępowania przy przygotowaniu próbek do badań powinien ulec modyfikacji. Podczas badań trwałości zapraw do murów zauważono, że niejednokrotnie sposób przygotowania próbek do badań może wpływać na uzyskane wyniki mrozoodporności zapraw. Problem ten dotyczy zarówno przygotowania w odpowiednich formach, zagęszczania, sezonowania, jak i suszenia próbek do badań. Wielokrotnie w praktyce laboratoryjnej Zakładu okazywało się, że próbki ulegały zniszczeniu przed poddaniem ich cyklom zamrażania-rozmrażania. W artykule przedstawiono wyniki badań mrozoodporności próbek zapraw przygotowanych i sezonowanych według różnych wariantów.
EN
Currently in Poland for assessment of the freeze-thaw resistance of the masonry and plastering mortars still withdrawn PN-85/B-04500 standard is applied. However, it seems that the proceeding during the preparation of the samples should be modified. In this connection, the durability tests were conducted. It has been noticed that the way of the sample preparation can clearly affect the obtained freeze–thaw mortar resistance results. It is complex issue related to sample preparation in the appropriated moulds, curing and drying processes as well. Repeatedly in laboratory practice it turns out that durability of the samples deteriorates even before taking proceeding of the freeze-thaw cycling. In this study the results of the freeze-thaw mortar resistance test are covered. The mortar samples were prepared and cured according to different approaches.
8
EN
One of the main threats to constructions made from rammed earth is destruction due to exposure to water. The way to limit this dangerous phenomenon is to supplement the local soil mixtures with stabilizing agents. The main component used is Portland cement. This article analyses the results of research which focused on the resistance of rammed earth to water erosion. Because of the lack of national standards regarding the method of examining the durability of rammed earth, the research was based on the New Zealand standard NZS 4298: 1998. The results confirm the possibility of using rammed earth stabilized by cement in a temperate climate.
PL
Jednym z głównych zagrożeń dla konstrukcji wykonywanych w technologii ziemi ubijanej jest destrukcja pod wpływem wody. Sposobem na ograniczenie tego niebezpiecznego zjawiska jest uzupełnienie mieszanki lokalnie dostępnych gruntów o składniki stabilizujące. Najczęściej stosowanym składnikiem jest cement portlandzki. W niniejszym artykule przeanalizowano wyniki badań odporności ziemi ubijanej na erozję wodną. Ze względu na brak krajowych norm dotyczących sposobu badania trwałości ziemi ubijanej, badania zostały wykonane w oparciu o normę nowozelandzką NZS 4298: 1998. Uzyskane wyniki pozytywnie weryfikują możliwość stonowania ziemi ubijanej stabilizowanej cementem w klimacie umiarkowanym.
EN
The paper presents the idea of durability valuation of building materials and elements subjected to the influence of atmospheric environment during their exploitation based on the laboratory tests carried out with the use of climatic chambers and ageing chambers. The special ageing stand for simulating climate influences and testing of building materials is presented. The apparatus works as a rotational chamber for accelerated ageing. Samples are installed inside and are subjected to artificial climatic factors, such as: sun radiation, rain and low temperature. Moreover, the results of study on method for definition of simulated climate program in the aging chamber for an examplary are natural climate of Upper Region are commented. Additionally, the results of examplary aging and durability tests for noise barriers are presented.
PL
Artykuł prezentuje problematykę oceny trwałości materiałów i elementów budowlanych poddanych w czasie eksploatacji oddziaływaniom środowiska atmosferycznego, na podstawie testów laboratoryjnych wykorzystujących komory klimatyczne oraz komory starzeniowe. Przedstawiono klimatyczną komorę starzeniową do symulacji oddziaływań klimatycznych i testowania trwałości materiałów budowlanych. Skomentowano wyniki prac nad metodyką ustalania programu klimatu symulowanego w komorze starzeniowej dla przykładowego klimatu naturalnego Górnego Śląska. Ponadto przedstawiono wyniki przykładowych testów starzeniowych akustycznych ekranów drogowych wraz prognozą ich trwałości
11
Content available remote The durability prediction of deteriorating reinforced concrete members
EN
The features of durability prediction and concepts of time-dependent reliability analysis of deteriorating reinforced concrete structures subjected to extreme gravity and lateral actions as rectangular pulse renewal processes are discussed. New methodological approaches to a time-dependent survival probability analysis and durability prediction of reinforced concrete members are considered. The safety margin of particular members is modeled as a random finite sequence. The effect of coincident recurrent extreme actions on their survival probabilities is analyzed. The instantaneous and long-term survival probabilities of particular and structural members of deteriorating structures are considered. It is recommended to calculate these probabilities by the unsophisticated analytical method of transformed conditional probabilities. The technical service life as a quantitative durability parameter of deteriorating structural members is studied.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.