Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 3

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  drut ortodontyczny
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
The phenomenon of corrosion of orthodontic appliances is of interest to both clinicians and researchers dealing with the issue of biocompatibility of medical materials. The oral cavity, due to its temperature fluctuations, changing pH, high humidity, action of mechanical forces and the presence of microorganisms is a favorable environment for degradation of dental materials. This article presents the comparative assessment of the intensity of corrosion of orthodontic archwires made of alloy steel, nickel–titanium and titanium–molybdenum alloys in laboratory conditions. Corrosion resistance examinations were carried out by means of the impedance and the potentiodynamic methods using an Autolab PGSTAT100 potentiostat/galwanostat (Eco Chemie B.V., Holand) with FRA2 module, in non-deaerated artificial saliva solution at 37 °C. An analysis of the impendence method's data showing that the highest corrosion resistance is observed for NiTi arches (3M, USA), while the lowest resistance for SS arches (3M, USA). These observations were confirmed by the data obtained from potentiodynamic tests; it was observed that the average corrosion current density [Icor] was the lowest for nickel–titanium archwires (3M, USA) and averaged 2.50 × 10−3 μA/cm2. The highest Icor corrosion current was observed in the case of steel wires from the same manufacturer and averaged 4.96 × 10−2 μA/cm2.
PL
Pojawienie się w organizmie żywym ciała obcego pobudza wiele mechanizmów mających na celu jego usunięcie. Gdy obca substancja, w tym przypadku drut metalowy, zostaje wykryta przez układ immunologiczny, organizm rozpoczyna produkcję antyciał o silnym działaniu utleniającym. Antyciała gromadzą się w pobliżu wszczepu i absorbują do biomateriału. Reakcja obronna organizmu staje się jedną z przyczyn degradacji biomateriałów. Stale austenityczne stosowane w medycynie należą do biomateriałów metalicznych szczególnie narażonych na niszczenie. Praca została poświęcona wpływowi środowiska korozyjnego na skuteczność zastosowanych połączeń spajających-naprawczych dla drutów NiTi.
EN
The appearance of the foreign matter in the organism stimulates many mechanisms aiming its elimination. So if the foreign substance, in this case the wire, is traced by immunological system, the organism starts production of anti-bodies of strong oxidizing functions. Antibodies consolidate near the implant and absorb into biomaterial. Defensive reaction of the organism is becoming one of the reasons of degradation of biomaterials. Austenitic steels, applied in medicine, belong to metallic biomaterials particularly exposed to damage. The work is devoted to the influence of corrosion environment on the structure and properties stability of NiTi wires after reparation.
PL
Stosowane metody łączenia materiałów stomatologicznych to: lutowanie, spawanie i zgrzewanie. Wszystkie te metody mają swoje wady i zalety. Aby uniknąć w dużym stopniu wad łączenia metali, powinno stosować się technikę spawu laserowego ze względu na: małe rozmiary wiązki laserowej, co zapewnia wysoką dokładność i trwałość łączenia materiałów, otrzymywanie spoin o wysokiej jednorodności, brak stosowania dodatkowych materiałów, bezkontaktowy proces łączenia, znikomą strefę przegrzania, co nadaje wyższą odporność spawu na korozję, otrzymanie spoiny o zbliżonych właściwościach wytrzymałościowych względem materiału rodzimego. Praca zawiera analizę zmian strukturalnych w spoinach drutów ortodontycznych oraz analizę wykresów pomiaru mikrotwardości.
EN
Dental material connecting methods used are: soldering, welding and sealing. All these methods have their advantages and disadvantages. Laser welding techniques should be used to avoid defects in metal binding as much as possible, due to: small size of the laser beam, which ensures precision and durability in material binding, welds achieved of high homogeneity, additional materials not being required, it is a non-contact binding process, a limited overheating zone, what gives higher weld resistance to corrosion, welds obtained with similar durability properties, related to the material used. This paper presents structural changes in orthodontic wire weld analyses and micro hardness measurement diagram analyses.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.