Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 3

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  drop size distribution
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
The homogeneity of an immiscible liquid–liquid system was investigated in a baffled vessel agitated by a Rushton turbine. The dispersion homogeneity was analyzed by comparing Sauter mean diameters and drop size distribution (DSD) determined in different measured regions for various impeller speeds. The sizes of droplets were obtained by the in-situ measurement technique and by the Image Analysis (IA) method. Dispersion kinetics was successfully fitted with Hong and Lee (1983) model. The effect of intermittency turbulence on drop size reported by Bałdyga and Podgórska (1998) was analyzed and the multifractal exponent 𝛼𝐹𝑇 was evaluated.
PL
Przedstawiono wpływ surfaktantu niejonowego Tweenu 80 na rozpad i koalescencję kropel. Zaobserwowano dodatkowe naprężenia rozrywające wynikające z różnicy między międzyfazowym napięciem równowagowym (dla t → ∞) i napięciem dynamicznym (dla t → 0), które zwiększają szybkość rozpadu kropel. Dla c = 0,0012 mM powierzchnie kropel pozostają częściowo ruchliwe. Natomiast dla c > 0,0012 mM koalescencja kropel jest znacznie utrudniona, dzięki czemu może być pominięta w równaniu bilansu populacji.
EN
The influence of surface active agent Tween 80 on drop breakage and coalescence is shown. Additional disruptive stresses connected with the difference between interfacial equilibrium tension (for t → ∞) and dynamic tension (for t → 0 ), and responsible for the increase of drop breakage rate were observed. For c = 0.0012 mM drop surfaces remain partially mobile, whereas for c > 0.0012 mM drop coalescence is significantly hampered. Therefore, it can be omitted in the population balance equation.
EN
Complete models in stirred tanks for the drop size distribution as a function of power-input, material and process parameters are rare and relatively inaccurate. Furthermore industrial applications, like e.g. suspension polymerization processes, require a distinct average drop diameter and a small standard deviation of the distribution. An overview is given for already existing measurement technique: sound, laser and photo based techniques. The Lasentec FBRM[zastrzeżony znak towarowy] [22], which gives online, and in-situ information and an in house developed endoscope technique [21] will be discussed in detail. It is clearly shown, that the laser based method gives only qualitatively good but fast results for the tested system toluene/water. The quantitatively accurate experimental results of the endoscope technique gave a good base for testing and developing numerical models for even transient behavior of drop size distributions.
PL
Kompletne modele rozkładu wielkości kropel w mieszalnikach mechanicznych w funkcji zapotrzebowania mocy, składników i parametrów procesu występują rzadko i są stosunkowo niedokładne. Dodatkowo, zastosowania przemysłowe, np. zawiesinowe procesy polimeryzacji wymagają dokładnego określenia średniej wielkości kropli i niskiej wartości odchylenia standardowego w rozkładzie. Przedstawiono przegląd stosowanych technik pomiarowych: akustycznych, laserowych i fotograficznych. Porównano zastosowanie i możliwości pomiarowe układu FBRM Lasentec[registred trademark] [22] z oryginalnym endoskopowym układem pomiarowym [21] dla układu toulen-woda. Widoczne jest, że technika laserowa daje szybkie wyniki, ale tylko jakościowe. Dokładne, ilościowe wyniki uzyskane techniką endoskopową stanowić mogą podstawę dla modeli numerycznych nawet w przejściowym zakresie rozkładu wielkości kropel.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.