Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 6

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  drinking water treatment
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
The biofiltration process in the biologically activated carbon filters (BAC) is one of advanced methods of water treatment. It enables efficient elimination of dissolved organic matter and some inorganic pollutants. The production of high-quality drinking water requires an appropriate method of filter work control based on biofilm growth assessment. The first aim of the study was to assess the microbial development in beds of two BAC filters with the use of various methods. The second aim was to compare the obtained results and indicate the method which could support filter operators during routine control of biofiltration process. The study was carried out in a pilot scale on models of BAC filters during two filter runs. The analysis of microorganisms was performed in water samples collected from different depths of the filter beds with the use of culture method (HPC), metabolic activity assay (with the FDA), epifluorescence microscopy – total cell count method (TCC) and biochemical method (system Vitek 2 Compact). No statistical correlation between HPC and metabolic activity assay was noted. Total bacteria number determined with the use of TCC was approx. 100–900 times higher than in the HPC method. The biochemical tests revealed the presence of several Gram-negative species. The comparison of the applied methods shows that microbial activity assay is the most useful, fast and low-cost method which may be applied additionally to the HPC method at standard water treatment plant laboratory.
PL
Przedstawiono wyniki badań nad wpływem usuwania domieszek występujących w wodzie naturalnej na skuteczność destrukcji mikrocystyn (MC) w procesie chlorowania. W badaniach wykorzystano wodę naturalną pobieraną ze Zbiornika Sulejowskiego, którą zanieczyszczono dodatkowo ekstraktem zawierającym MC. Wodę poddawano oczyszczaniu w procesie filtracji oraz porównawczo koagulacji i filtracji. Chlorowanie prowadzono z użyciem podchlorynu sodu. Badania obejmowały wpływ dawki chloru na stopień usuwania MC z wody oraz zależność stopnia destrukcji MC od czasu kontaktu z chlorem. Stwierdzono, że efektywność destrukcji MC wzrastała wraz ze zwiększaniem stopnia usuwania domieszek wody. Destrukcja MC następowała we względnie krótkim czasie, wynoszącym 15 minut. Wymagana dawka chloru umożliwiająca destrukcję MC była pięciokrotnie mniejsza w przypadku wody oczyszczonej w procesie koagulacji i filtracji niż wody surowej.
EN
Periodical occurance of intense blue-green algal blooms in impounded water which is used for municipal supply is an indication of the elevated nutrient level. Some blue-green algae (cyanobacteria) such as Microcystis produce cyclic heptapeptide toxins including microcystins (MCs). MCs are commonly classed as hepatotoxins due to the damage of liver cells after consumption. There are currently known more than 70 structural variations of MCs. That diversity is caused by the presence of variant amino-acids. MC-LR is the most toxic among them. MCs can be removed during water treatment by activated carbon or by ozonation but these methods are relatively expensive. Chlorination may be an effective and practical method for the removal of MCs from drinking water. The drawback of this process is the formation of undesirable byproducts in the case of organic matter presence in the treated water. Chlorine is the reagent commonly employed in the disinfection of drinking water. The low natural organics concentration ensures the target compounds (MCs) destruction. Results of the investigations on the effect of natural organic matter removal on MCs degradation by chlorination during surface water treatment are presented in the article. Natural surface water taken from the Sulejów Reservoir contaminated additionally with MCs generated by the blue-green algae Microcystis aeruginosa was purified in the laboratory by the application of filtration or coagulation/filtration methods. The MCs concentrations were similar to those typically observed in raw water (about 10 mg/l). Sodium hypochlorite was used as a chlorinating agent. Effect of chlorine dosage and contact time on the MCs degradation was assessed in this work. The destruction of the toxins was monitored using three methods including PPIA (Protein Phosphatase Inhibition Assay), ELISA (Enzyme-Linked ImmunoSorbent Assay) and HPLC-DAD (High Performance Liquid Chromatography). The kinetics of the MCs destruction and chlorine consumption for the chlorination of natural organic matter with an excess of chlorine was investigated. MCs destruction and chlorine consumption could be described by second order kinetics. Rate constants for MCs destruction were between 0.027 l/mg min. for MC-LR, similar to that obtained for total MCs (0.016 l/mg min.) and 0.077 l/mg min. for MC-YR (pH = 7). It was stated that toxins degradation efficiency increased as the water contamination decreased. Degradation of MCs took place within relatively short time of 15 minutes. Rate constants for the destruction of total MCs were of 0.042 l/mg min. in the water after filtration and 0.079 l/mg min in the water after coagulation/filtration processes when the pH was equal 7. The required dosage of chlorine for the MCs destruction was five times lower when water treatment by the coagulation/filtration processes was applied.
PL
Przedstawiono wyniki badań nad koagulacją domieszek wody pobranej w okresie późnego lata ze Zbiornika Sulejowskiego, zanieczyszczonej dodatkowo mikrocystynami (MC), toksynami pochodzenia sinicowego. W badaniach użyto MC wyekstrahowanych z naturalnego materiału biologicznego zdominowanego przez sinice Microcystis aeruginosa. Sumaryczne stężenie analizowanych form MC wynosiło ok. 10 µg/l (MC-LR, MC-RR i MC-YR). Podczas usuwania domieszek rozpuszczonych, w tym MC, wykorzystano pylisty węgiel aktywny (PWA) CWZ-22. Czas kontaktu PWA z wodą surową wynosił 15 minut oraz dodatkowe 45 minut podczas flokulacji i sedymentacji. Domieszki w postaci koloidów i zawiesin o wysokim stopniu dyspersji oraz dodanego PWA usuwano z wody przy użyciu siarczanu glinu i porównawczo wstępnie zhydrolizowanego koagulantu PAC 10WA. Większą skuteczność usuwania substancji rozpuszczonych stwierdzono po skojarzeniu PWA i siarczanu glinu. W wyniku zastosowania adsorpcji przy użyciu PWA CWZ-22 i koagulacji siarczanem glinu osiągnięto wysoki stopień usuwania MC z wody (usunięto 63% MC-LR przy dawce CWZ-22 wynoszącej 50 mg/l), chociaż nie uzyskano całkowitej ich eliminacji. Zadowalający stopień usuwania MC uzyskano po wydłużeniu sumarycznego czasu kontaktu domieszek wody z PWA do ok. 1,5 h.
EN
Results of the investigation on the treatment of water taken from the Sulejów Reservoir (Central Poland) during late summer are presented in the article. Water was contaminated additionally with microcystins (MCs) generated by blue-green algae. MCs were extracted from the natural biological material collected from the Sulejów Reservoir in which the blue-green algae Microcystins aeruginosa dominated. Total MC's concentration was of about 10 µg/l (MC-LR, MC-RR and MC-YR). Microcystins analysis were carried out by high performance liquid chromatography (HPLC) with photo-diode array detection. Microcistin concentrations were determined by comparision of peak areas with those of standards. Comparison of isotherms obtained for MC-LR, MC-YR and MC-RR suggested that three variants did not show a significant difference in sorption performance. Applied contact time was of 15 minutes. Colloids and suspended matter as well as introduced PAC with adsorbed MCs were removed by means of alum and in comparison by polyaluminium chloride (PAC 10WA). Higher efficiency of dissolved matter removal from purified water was obtained as a result of PAC, CWZ-22 and alum application. MC-LR percentage removal equal 63% was obtained as a result of 50 mg/l of PAC and 120 mg/l of alum introduction. Unfortunately, entire elimination of MC was not obtained. Total MC concentration was reduced from 9.4 to 1.0 mg/l when the contact time was as long as 1.5 hour.
PL
W artykule przedstawiono wyniki zastosowania w warunkach laboratoryjnych takich koagulantów jak: tlenek wapnia (CaO), sody kalcynowanej lekkiej i twardej (Na2CO3), wodorotlenku sodu (NaOH), fosforanu trójsodowego (Na2PO4) oraz ich mieszanin do oczyszczania wód podziemnych, zawierających podwyższoną twardość ogólną wahającą się od 475 do 507 mg·dm-3 oraz zawartość żelaza od 0,2 do 2,0 mg·dm-3. Wyniki badań wskazują, że najbardziej optymalnym pod względem ekonomicznym i wielkości redukcji koagulantem była soda kalcynowana, której koszt w przeliczeniu na m3 wody wyniósł 0,6 zł przy 50 % redukcji twardości ogólnej i 98,5 % redukcji żelaza. Pozostałe koagulanty dawały wyższy koszt produkcji nr wody oraz mniejszy lub zbliżony procent redukcji twardości ogólnej i zawartości żelaza.
EN
In the article were presented the results of application in laboratory conditions, coagulants like calcium oxide (CaO), light and hard soda carbonate (Na2CO3), sodium hydroxide (NaOH), threesodium phosphate (Na3PO4) and their mixture, to underground waters treatment, which contain the higher level of total hardness (between 475 and 507 mg·dm-3) and iron amount (from 0,2 to 2,0 mg·dm-3), The results showed that, the most optimal as regarts on economy and reduction quantity, coagulant was soda carbonate, which cost amount to 0,6 zl / m3 water with 50% reduction of total hardness and iron amount reduction by 98,5%. Other coagulants gave higher costs production of m3 water and lower or similiar percent of total hardness reduction and iron content.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.