Ograniczanie wyników
Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 2

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  double-ceramic-layer
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
The paper presents the results of numerical calculation of the temperature distribution and thermal stresses in model of two layered thermal barriers coatings of DCL type deposited on the superalloy coupons with NiCrAlY bond-coat. The variable parameter was the thickness of bond-coat layers. In all cases it was assumed that the bond-coat would be the NiCrAlY type coat obtained by plasma spraying, just as the outer insulating layer. The thickness of the bond-coat layer is 100 μm to 300 μm. As the substrate material, the In 625 nickel superalloy was adopted. The insulation layer of TBC systems was built from outer sublayer based on La2Zr2O7 (LZO) ceramic and internal layer was built from conventional 8YSZ. A total thickness of insulation layer was assumed as 300 μm. Presented analysis showed that the overall thickness of bond-coat has important influence on the temperature distribution as well as the thermal stresses. The maximum temperature differences between extreme thickness value was calculated on the level of 50°C.
PL
W opracowaniu przedstawiono wyniki obliczeń numerycznych rozkładu temperatury i naprężeń termicznych w powłokowych barierach cieplnych typu DCL naniesionych na elemencie nadstopu z warstwą wiążącą typu NiCrAlY. Zmiennym parametrem była grubość warstw wiążących. We wszystkich przypadkach założono, że powłoka wiążąca była powłoką typu NiCrAlY otrzymaną przez natryskiwanie plazmowe, podobnie jak zewnętrzna warstwa izolacyjna. Grubość warstwy powłoki wiążącej wynosi od 100 μm do 300 μm. Jako materiał podłoża przyjęto super -stop niklu In 625. Warstwa izolacyjna systemów TBC została zbudowana z zewnętrznej warstwy nośnej na bazie ceramicznej La2Zr2O7 (LZO), natomiast wewnętrzna warstwa została zbudowana z konwencjonalnego proszku 8YSZ. Całkowitą grubość warstwy izolacyjnej przyjęto jako 300 μm. Przedstawiona analiza wykazała, że całkowita grubość warstwy wiążącej ma istotny wpływ na rozkład temperatury, jak również na naprężenia termiczne. Maksymalne różnice temperatur pomiędzy ekstremalną wartością grubości obliczono na poziomie 50 ° C.
EN
The paper presents the results of numerical calculations of the temperature distribution and thermal stresses in two systems of layered thermal barrier coatings (TBC) of DCL (double-ceramic--layer) type deposited on the In625 Ni-based superalloy by atmospheric plasma spraying (APS). Conventional monolayered TBC obtained from 8YSZ (6-8% wt. Y2O3×ZrO2) and LZO (La2Zr2O7) powders with an insulation layer thickness of 300 μm was used as the reference material. Numerical analysis was applied to the DCL TBC systems in which the external ceramic layer was obtained from LZO powder, while the internal layer was a 8YSZ zone. The thickness of both types of ceramic sublayers was a variable parameter. In all cases it was assumed that the bond-coat would be the NiCrAlY type of coating obtained by atmospheric plasma spraying. The thickness of the bond-coat layer was 200 microns. The starting point was a TBC system with the same thickness of both zones (150 μm each), while further variants included coatings with the following mutual ratios of thickness of both materials (sub-layers):20/80, 30/70, 50/50, 70/30 and 80/20. The purpose of these analyses was to determine the optimum value of the thickness ratio of individual ceramic zones in DCL coatings, not only from the point of view of the insulation effect, but primarily the state of stresses determining the durability of the entire TBC system. Numerical analysis of stress and temperature distribution indicates that the life cycle of DCL coatings should be strongly dependent on the thickness ratio of ceramic zones LZO and YSZ, while the two-layer coatings show better aggregate insulation characteristics and related stress states.
PL
W opracowaniu przedstawiono wyniki obliczeń numerycznych rozkładu temperatury i naprężeń cieplnych w dwuwarstwowych powłokowych barierach cieplnych (DLC double-ceramic-layer) naniesionych na elemencie z nadstopu niklu metodą natrysku cieplnego. Jako punkt odniesienia przyjęto konwencjonalne powłokowe bariery cieplne (TBC) otrzymane z proszku 8YSZ (6-8% wagowych Y2O3 x ZrO2) oraz LZO (La2Zr2O7) o grubości warstwy izolacyjnej na poziomie wynoszącym 300 μm. Analizie numerycznej poddano powłoki TBC, w których zewnętrzną warstwę ceramiczną otrzymano z proszku LZO, natomiast warstwą wewnętrzną była strefa 8YSZ. Grubość obu rodzajów warstw ceramicznych była parametrem zmiennym. We wszystkich przypadkach przyjęto, że warstwa podkładowa to powłoka typu NiCrAlY otrzymana metodą natrysku plazmowego, podobnie jak zewnętrzna warstwa izolacyjna. Grubość warstwy wiążącej wynosiła 200 mikronów. Punktem wyjścia był system TBC o tej samej grubości obu stref (każda o grubości 150 μm), podczas gdy kolejne warianty obejmowały powłoki o następujących wzajemnych stosunkach grubości obu materiałów (podwarstw): 20/80, 30/70, 50 / 50, 70/30 i 80/20. Celem tych analiz było określenie optymalnej wartości stosunku grubości poszczególnych stref ceramicznych w powłokach DCL, nie tylko z punktu widzenia efektu izolacji, ale przede wszystkim stanu naprężeń determinujących trwałość całego układu TBC. Analiza numeryczna rozkładu naprężeń i temperatury wskazuje, że cykl życia powłok DCL powinien być silnie uzależniony od stosunku grubości stref ceramicznych LZO i YSZ, podczas gdy powłoki dwuwarstwowe wykazują lepszą charakterystykę izolacji kruszywa i związany z tym stan naprężenia.
first rewind previous Strona / 1 next fast forward last