Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 2

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  double closed loop
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
1
Content available remote Analysis Research of Control Method Model on Automobile Brake Test Rig
EN
This paper, firstly in accordance with the engineering design method, PID controller are used to control the current loop and speed loop common on double closed-loop DC converter, and build dual-loop PID control model, and Matlab’s emulation to model, as well as analysis and evaluate the structural of the simulation. Because conventional PID control can not meet the parameters of the controlled object changes and lack of non-linear characteristics, the fuzzy self-tuning PID can overcome the uncertainty and nonlinear objects, furthermore the fuzzy self-tuning PID has more flexibility and adaptability, so this paper putting to use fuzzy self-tuning PID controller for dual-speed loop in the closed-loop system to transform, so that it has not or less affected by the object model, you can achieve high performance, robustness and other advantages.
PL
W artykule opisano metodę testowania system hamulcowego w pojazdach samochodowych. Ay uniezależnić wyniki testu od parametrów układu sterowania zaproponowano ulepszony kontroler PID z automatycznym strojeniem i wykorzystaniem logiki rozmytej.
2
Content available remote An Improved Double Closed Loop Control Strategy for Air Plasma Cutting Converter
EN
A double closed loop control strategy composed of inner voltage-loop and external current-loop with a current-reference feedforward link was proposed based on the output characteristic of an air plasma cutting converter(APCC) with non-contact arc ignition. An equivalent mathematical model of the APCC was presented and a controller was designed via frequency domain analysis. Experiments verified that the proposed control strategy showed excellent dynamic and static performance, which significantly improved the arc ignition and the robustness against load disturbance.
PL
Przedstawiono strategię sterowania konwertera do cięcia plazmowego z podwójną pętlą złożoną z wewnętrznej pętli napięcia i zewnętrznej prądowej. Przedstawiono model matematyczny i projekt z analizą w domenie częstotliwości. Obiekt sprawdzono eksperymentalnie.