Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 2

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  dosage form
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
Tramadol, a strong pain killer known for its addictive problems is either co-administrated or co-formulated with other analgesics or muscle relaxants. The power of fluorescence detection in HPLC is tested to resolve such mixtures in plasma matrix to reach the required sensitivity with simple sample treatment using just protein precipitation. The aim of this work was to develop an eco-friendly and sensitive HPLC method with fluorimetric detection for analysis of Tramadol in its two binary mixtures with Ibuprofen (mixture 1) and Chlorzoxazone (mixture 2) in two combined dosage forms and spiked plasma. Separation was done using a C18 column with mobile phase of acetonitrile and water (pH 3.5) in gradient elution and 1 mL/min flow rate. Detection was carried out with λ excitation/λ emission of 220 and 307 nm, respectively. The method was applied to detect the two binary mixtures in real plasma samples after invivo application to rats, to assure that the drugs’ metabolites do not affect the sensitivity or selectivity of the assay. Evaluation of greenness of the proposed method was done using semi-quantitative Eco‐Scale and new Green Analytical Procedure Index which showed that this method can be a greener alternative with higher sensitivity for analysis of both mixtures. The method (15 min-assay) was linear over concentrations of 0.1–10 μg/mL and 0.1–33 μg/mL in plasma. In addition, the proposed method was validated per ICH as well as FDA bioanalytical methods’ validation guidelines.
EN
A novel stability-indicating reversed-phase (RP) HPLC method has been developed and validated for quantitative analysis of eplerenone in the bulk drug and in a pharmaceutical dosage form. Use of a 250 mm × 4.6 mm, 5-μm particle, C18 column with 55:45 ( v/v ) 50 mM ammonium acetate buffer (pH 7)-acetonitrile as isocratic mobile phase enabled separation of the drug from its degradation products. UV detection was performed at 240 nm. The method was validated for linearity, accuracy (recovery), precision, specificity, and robustness. The linearity of the method was excellent over the range 10–100 μg mL -1 (correlation coefficient 0.999). The limits of detection and quantification were 0.019 and 0.053 μg mL -1, respectively. Recovery of eplerenone from the pharmaceutical dosage form ranged from 100.97 to 101.25%. Eplerenone was subjected to stress conditions (hydrolysis (acid, base), oxidation, photolysis, and thermal degradation) and the stressed samples were analysed by use of the method. Degradation was observed in acid, base, and 30% H 2 O 2 . The drug was stable under the other stress conditions investigated. The degradation products were well resolved from main peak. The forced degradation studies prove the stability indicating power of the method.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.