EN
The development of energy storage technology introduces a new legal framework in the global electricity markets. Unfortunately, it often happens that current legal regulations make it difficult or even impossible to use energy storage facilities for ancillary services. In particular, this problem concerns relatively modern energy storage technologies, such as battery energy storage systems (BESS). The article presents legal issues related to the construction, operation and management of electric energy storage facilities in distribution grids. The formal and legal aspects of functioning of mobile energy storage facilities located in electric vehicles, ie the use of Vehicle-to-Grid technology, were also discussed. The authors analyzed European and national legal acts. Polish ancillary services were also described in terms of using stationary and mobile energy storage facilities. After the analysis of the aforementioned topics, it was concluded that the current European and Polish regulations are not fully capable of establishing a dedicated market for energy storage services. Significant changes are required to allow for the participation of Distribution System Operators in the process of establishing and using ancillary services as well as provisions regulating the aspects of management and operation of energy storage facilities operating on the distribution grid.
PL
Rozwój technologii magazynowania energii wprowadza nowy porządek prawny na rynkach energii elektrycznej na świecie. Niestety, często zdarza się, że obecne regulacje prawne utrudniają lub wręcz uniemożliwiają wykorzystanie magazynów energii w realizacji usług systemowych. W szczególności ten problem dotyczy relatywnie nowych technologii magazynowania jakimi są bateryjne magazyny energii elektrycznej (BESS). W artykule przedstawiono zagadnienia prawne dotyczące budowy, eksploatacji oraz zarządzaniami magazynami energii elektrycznej w sieciach dystrybucyjnych. Poruszono także aspekty formalno-prawne funkcjonowania mobilnych magazynów energii znajdujących się w pojazdach elektrycznych tj. wykorzystanie technologii Vehicle-to-Grid. Autorzy przeanalizowali europejskie jak i krajowe akty prawne. Dokonano także opisu polskich usług systemowych pod kątem wykorzystania w nich stacjonarnych i mobilnych magazynów energii. Po analizie ww. zagadnień stwierdzono, że obecne przepisy zarówno europejskie jak i krajowe nie są w pełni zdolne do stworzenia rynku usług magazynowania energii. Wymagane są istotne zmiany dopuszczające udział Operatorów Systemów Dystrybucyjnych w tworzeniu i wykorzystywaniu regulacyjnych usług systemowych oraz zapisy regulujące aspekty zarządzania i eksploatacji magazynów energii działających na sieć dystrybucyjną.
EN
The paper presents an evaluation of MV/LV power transformer damage risk due to the impact of ambient temperature at their operation location. It features a presentation of the method of evaluating the power structures’ reliability in the conditions of the structures’ variable durability and exposure values. Based on perennial observations of ambient temperature and failure rate of MV/LV transformers, it was demonstrated that temperature is a factor that causes damage or is jointly responsible for the damage caused in all of the devices’ other failures.
PL
W artykule przedstawiono propozycję wykorzystania łączników zdalnie sterowalnych do obniżenia strat energii elektrycznej w sieci SN przy uwzględnieniu dobowych zmian zapotrzebowania. Porównano wartości strat energii elektrycznej na analizowanym fragmencie sieci przy założeniu braku ingerencji dyspozytora w układ pracy sieci, rekonfiguracji sieci zgodnie z opracowanym wcześniej harmonogramem oraz rekonfiguracji sieci w odpowiedzi na aktualne zmiany zapotrzebowania.
EN
DSOs are seeking for MV grid reliability improvements in order to decrease occurrence of power supply interruptions and improve voltage quality. As a result, the automatization of medium voltage grid is progressing. In parallel, independently from grid improvements plans, the amount of distributed generation installed power is increasing. This leads to loading and voltage variations. The inversed power flows are more common as they are depended on the correlation between demand and availability of energy source, like wind and sunshine. There is an expectation that battery energy storage and electric vehicle, new types of objects connected to power system, will have a crucial impact on the grid performance at near future. There is a need to develop smart solutions due to fact, that MV grid development is not economically effective way to deal with all new problems. The proposal of MV grid operation improvement will be presented in the article. Remote controlled switches together with measurement devices will be utilized to reconfiguration of the grid as a response to varying demand. The scheduled and on-line reconfiguration operation schemes will be taken into consideration. Finally, the grid performance for aforementioned operation schemes will be executed and compared.
EN
Dynamic development of smart grids enables the use of controllable switches to change the MV distribution grid configuration. The paper discusses the impact of the MV distribution system reconfiguration on the active power losses with consideration of daily load variation. Based on the 33-node IEEE distribution system modified by the author, the problem of selecting the appropriate algorithm sensitivity was presented, and a methodology for selecting the MV distribution grid operation configuration in the 24-hour cycle was proposed. The objective function is the minimum active power losses. The tests were carried out in the DIgSILENT Powerfactory flow program for two variants of load curves and for different sensitivity factors. The calculation results demonstrate improvement of the MV distribution system’s operating conditions and the essence of the problem of selecting the appropriate grid reconfiguration algorithm sensitivity.
PL
Dynamiczny rozwój inteligentnych sieci elektroenergetycznych umożliwia wykorzystanie sterowalnych łączników do zmiany konfiguracji sieci rozdzielczej SN. W artykule omówiono wpływ rekonfiguracji systemu dystrybucyjnego SN na wartość strat mocy czynnej z uwzględnieniem dobowej zmienności obciążenia. Bazując na zmodyfikowanym przez autora 33-węzłowym systemie dystrybucyjnym IEEE, przedstawiono problem doboru odpowiedniej czułości algorytmu oraz zaproponowano metodykę wyboru konfiguracji pracy sieci rozdzielczej SN w cyklu dobowym. Jako funkcję celu zastosowano kryterium minimalizacji strat mocy czynnej. Badania przeprowadzono w programie rozpływowym DIgSILENT Powerfactory dla dwóch wariantów krzywych obciążenia i dla różnych wartości współczynnika czułości. Wyniki obliczeń dowodzą poprawy warunków pracy systemu dystrybucyjnego SN oraz istoty problemu doboru odpowiedniej czułości działania algorytmu rekonfiguracji sieci.
EN
The article presents effects of excessive installation of photovoltaic panels operating with distribution grids in Czech Republic.
PL
Przedstawiono skutki nadmiernego instalowania indywidualnych układów fotowoltaicznych współpracujących z siecią dystrybucyjną w Republice Czeskiej.
PL
Problem optymalizacji konfiguracji elektroenergetycznych sieci dystrybucyjnych przy zmieniającym się obciążeniu oraz w stanach awarii sieci może być rozpatrywany jako problem optymalizacji wielokryterialnej. W artykule zaprezentowano algorytm koewolucyjny z pamięcią na poziomie populacji, pozwalający na odszukiwanie rozwiązań paretooptymalnych, jakim są w analizowanym zadaniu optymalizowane konfiguracje sieci. Opracowana metoda wykorzystuje przy organizacji tzw. pamięci populacyjnej algorytmu ewolucyjnego podstawy teoretyczne systemów klasyfikujących. Przedstawiona w artykule metoda umożliwia efektywne odszukiwanie optymalnych konfiguracji sieci dystrybucyjnych dla różnych obciążeń sieciowych oraz dla stanów awarii sieci.
EN
The methodology of restoring power supply to consumers in case of a distribution grid failure is an important issue in the literature on operation and reliability of electrical energy distribution grids. Presented is here a concept of a new method which supports the work of distribution grids operators in case of a failure with the use of a classifier system working in tandem with a coevolutionary algorithm. The method presented here enables constructing scenarios for adjustments of medium voltage power distribution grids configuration (power system switchgear operation adjustments). The developed method is based on theoretical rudiments of genetic-based machine learning systems. This method uses informations on previous power distribution grid failures and enables using information from the simulated failures. Decision variables which, among other things, take into account the reliability parameters of distribution grid elements, have been described using the fuzzy set theory. Described are also sample calculations related to failures of a selected power distribution grid with the aid of the developed method.
PL
Artykuł przedstawia zastosowania układów energoelektronicznych we współczesnych i przyszłych rozwiązaniach sieci energetycznych wyposażonych w elementy technologii SmartGrid i Vehicle To Grid. Przedstawione zostały także podstawy działania tych technologii z uwzględnieniem ich wpływu na system energetyczny.
EN
The paper introduces application of power electronics devices into the modern and future electric grids equipped with SmartGrid and Vehicle To Grid technology. Fundamentals of operation of these technologies have been described as well as their influence on power system.
PL
Stwierdzono, iż w celu ograniczenia strat energii elektrycznej w sieciach przesyłowych i dystrybucyjnych, zwiększenia pewności zasilania, wyeliminowania zbędnej emisji do środowiska CO2, SO2, NOx i popiołów oraz ograniczenia kosztów zabezpieczenia obiektów krzyżowanych, wszystkie prace związane z wymianą izolatorów i przeizolowaniem linii 110 kV należy wykonywać technologią PPN.
EN
There is proved that - in order to limit electric energy losses in transmission and distribution grids, to increase the supply reliability, to eliminate superfluous CO2, SO2, NOx emission and to limit cost of protection of all crossed objects - all works concerning the particular insulator exchange and all insulation change of 110 kV lines should be done as the live line works.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.