Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 11

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  distributed power generation
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
In low-voltage power networks with a large share of distributed energy sources, the phenomenon of overvoltage is increasingly observed. Although it may be desirable to raise the voltage value downstream of the network, in some cases the upper allowable voltage limit is exceeded.The method of eliminating voltage rises commonly used in the Polish power system is the installation of overvoltage protections, disconnecting the source from the grid. Such action reduces the profitability of prosumer installations, discouraging future potential investors. It turns out, however, that this is not the only disadvantage of such a solution. Sudden and uncoordinated disconnections and reconnections of more energy sources cause abrupt voltage changes that negatively affect the voltage conditions in the network.The aim of the paper is to present the operating algorithms of a standard overvoltage relay used in inverters of photovoltaic microinstallations. These algorithms –described in standards and national regulations –were tested in a typical inverter used in public low-voltage networks and implemented in the created simulation model of the relay. The described tests will be used for further work to demonstrate the need to coordinate the operation of overvoltage protections or replace them with other measures to improve voltage conditionsin the grid with high share of photovoltaic sources.
PL
W sieciach elektroenergetycznych niskiego napięcia z dużym udziałem rozproszonych źródeł energii coraz częściej obserwuje się zjawisko podskoku napięcia. Choć samo podniesienie wartości napięcia w głębi sieci może być pożądane, to jednak w niektórych przypadkach dochodzi do przekroczenia górnej dopuszczalnej granicy napięciowej. Powszechnie stosowanym w polskim systemie elektroenergetycznym sposobem eliminacji podskoków napięcia jest instalowanie zabezpieczeń nadnapięciowych, wyłączających źródło z sieci. Działanie takie obniża opłacalność instalacji prosumenckich, zniechęcając przyszłych potencjalnych inwestorów. Okazuje się jednak, że nie jest to jedyna wada takiego rozwiązania. Nagłe i nieskoordynowane wyłączenia i ponowne załączenia większej liczby źródeł energii powodują skokowe zmiany napięcia, które negatywnie wpływają na warunki napięciowe w sieci. Celem artykułu jest zaprezentowanie algorytmów działania standardowego przekaźnika nadnapięciowego stosowanegow falownikach mikroinstalacji fotowoltaicznych. Algorytmy te – opisane w normach i krajowych przepisach –przetestowano w typowym falowniku stosowanym w publicznych sieciach niskiego napięcia oraz zaimplementowano w utworzonym modelu symulacyjnym przekaźnika. Opisane badania posłużą do dalszych prac, mających wykazać konieczność koordynacji działania zabezpieczeń nadnapięciowych lub zastąpienia ich innymi środkami poprawy warunków napięciowych w sieci z dużym nasyceniem fotowoltaiką.
PL
W artykule opisano krajowe doświadczenia w dziedzinie projektowania i wykonawstwa turbin parowych małej mocy (do 400 kW) dla energetyki rozproszonej na tle turbin dostępnych na rynku. Omówiono własne konstrukcje, możliwości obliczeniowe i uwarunkowania technologiczne oraz przedstawiono estymacje kosztów wytwarzania takich maszyn.
EN
In the current paper national experiences within the area of design and manufacturing of low power steam turbines (up to 400 kW) for distributed power generation are described, in relation to turbines available on the market. Our original constructions have been appropriately addressed, including computational possibilities and manufacturing conditions. We also demonstrate cost estimates for producing such machines.
EN
The article describes the impact of a fuel-consuming power generator on energy production costs. The research isbased on a thermodynamic engine model for which the energy source is hydrocarbon fuel. The results of the studies on the thermodynamic engine are energy costfunctionsfor which the variableis electrical power. The presented characteristics reflect the impact of fuel prices on the minima of the cost function. In addition, the characteristics reflect the location of the extremes of functions in the coordinate system relative to the maximum of the function of efficiency. The article concludes witha cost model for thermodynamic engines for which hydrocarbon fuel is purchased. Article proposes the cooperation of generators with renewable sources to increase and stabilize the power rating of power systems.
PL
Artykuł opisuje wpływ mocy generatora energii zużywającego paliwo na koszty wytwarzania energii. Badania bazują na modelu silnika termodynamicznego, dla którego źródłem energii jest paliwo węglowodorowe. Efektami badań silnika termodynamicznego są funkcjekosztów energii, dla których argumentem jest moc elektryczna. Zaprezentowane charakterystyki uwzględniają wpływ cen paliwa na minima funkcji kosztów. Ponadto charakterystyki odzwierciedlają położenie ekstremów funkcji w układzie współrzędnych względem maksimum funkcji sprawności. W podsumowaniu artykuł prezentuje model wyznaczania kosztów dla silników termodynamicznych, dla których kupowane jest paliwo węglowodorowe. W artykule zaproponowano współprace generatorów ze źródłami odnawialnymi w celu zwiększenia i stabilizacji mocy znamionowych systemów elektroenergetycznych.
EN
Deterioration of voltage conditions is one of the frequent consequences of connecting an increasing number of photovoltaic sources to the low-voltage (LV) power grid. Under adverse conditions, i.e. low energy consumption and high insolation, microgeneration can cause voltage surges that violate acceptable limits. Research shows that the increase in voltage is the main limitation for connecting new energy microsources to the LV network and forces the reconstruction of the network. An alternative to costly modernizations can be the implementation of appropriate strategies for controlling network operation to maintain the voltage at the required level. The article presents an overview of the methods and concepts of voltage control in a low-voltage network developed so far to mitigate the undesirable phenomenon of voltage boosting. The focus was mainly on local methods - not requiring communication infrastructure - as best suited to the conditions of Polish distribution networks. Gathering the results of many tests and simulations carried out in different conditions and on different models allowed for the formulation of general conclusions and can be a starting point for further research on acontrol method that can be widely used in the national power system.
PL
Jedną z częstych konsekwencji przyłączania do sieci elektroenergetycznej niskiego napięcia (nn) coraz większej liczby źródeł fotowoltaicznych jest pogorszenie warunków napięciowych. W niesprzyjających warunkach – przy niskim poborze energii i wysokim nasłonecznieniu – mikrogeneracja może powodować podskoki napięcia przekraczające dopuszczalne granice. Badania pokazują, że wzrost napięcia stanowi podstawowe ograniczenie dla przyłączania nowych mikroźródełenergii do sieci nn i wymusza przebudowę sieci. Alternatywą dla kosztownych modernizacji może być wdrożenie odpowiednich strategii sterowania pracą sieci pozwalających utrzymać napięcie na wymaganym poziomie. W artykule zaprezentowano przegląd opracowanych dotychczas metod i koncepcji regulacji napięcia w sieci nn mających na celu opanowanie niepożądanego zjawiska podbicia napięcia. Skupiono się głównie na metodach lokalnych – nie wymagających do prawidłowego działania infrastruktury komunikacyjnej –jako najlepiej przystosowanych do warunków polskich sieci dystrybucyjnych. Zebranie wyników badań i symulacji, przeprowadzonych przy różnychzałożeniach i na różnych modelach, pozwoliło na sformułowanie ogólnych wniosków i może stanowić punkt wyjścia do dalszych badań nad metodą sterowania mogącą znaleźć szerokie zastosowanie w krajowym systemie elektroenergetycznym.
PL
W artykule zaprezentowano wypracowane doświadczenia oraz poglądy na temat wykorzystania odnawialnych źródeł energii (OZE) w Krajowym Systemie Elektroenergetycznym (KSE). Poglądy te uwzględniają potrzebę współpracy różnych źródeł i sposobów wytwarzania energii oraz wyróżniają potrzeby organizacyjne, które przystosowują funkcjonowanie generacji rozproszonej do aktualnych systemowych standardów. Efektami wykonanej pracy są stworzone charakterystyki kosztów wytwarzania energii w modelowym generatorze. W referacie odwołano się do funkcji i sposobów funkcjonowania kogeneracji i OZE w energetyce rozproszonej.
EN
The article addresses the impact of energy prices on the economic range of power regulation in the fuel powered generator. The effect of the sale prices of energy generated in the model on the economic work of the generator is included in the results. The result of the work done in the article are families of price characteristics produced in the model. The article resorts to the use of renewable energy sources as a complement to the generator consuming fossil fuel. The calculated families of energy price characteristics take into account the overall efficiency of the model generator. The use of renewable energy sources in the national power system is considered. The characteristics obtained in the article are based on a simplified model of a thermal engine operating in combined heat and power generation. Energy costs and prices including energy losses and energy costs without losses in the generator are compared. The publication also discusses the role of cogeneration in distributed power generation and considers different possibilities of using cogeneration. In the summary, the article gives a way of calculating the costs of energy production, with allowance for energy losses resulting from total efficiency in the engine.
EN
The main objective of this paper is focused on the real time implementation in a MATLAB/SIMULINK environment of a closed-loop hybrid control strategy structure consisting of a combination of Fuzzy Logic control approach and a standard PID control strategy. This strategy is applied to control the speed of a 2 HP 1750 rpm permanent magnet DC motor used in a wide range of HVAC applications. The novelty of the paper is the new modeling approach by using SIMULINK SIMSCAPE library blocks, more practical due to its simplicity, easier and faster to implement and, in particular, very easy to practice for MATLAB users compared to a traditional modelling approach. The DC motor can be powered by a unidirectional DC voltage converter connected to a 10 kW-Microgrid PV array or directly from a Li-Ion battery or a Supercapacitor, both connected via two bidirectional DC boost-buck converters to the same Microgrid. The Microgrid energy storage system is suitable for renewable energy applications that are connected to a local grid, thus releasing the overloaded national grid, saving a considerable amount of energy and drastically reducing the energy costs.
PL
Pomimo prawie dwustuletniej historii badań i rozwoju, silnik Stirlinga również współcześnie stanowi obiekt zaawansowanych badań modelowych i eksperymentalnych. Obecnie, badania te motywowane są głównie jego korzystnymi charakterystykami środowiskowymi, możliwością wykorzystania w różnorodnych układach technologicznych i brakiem restrykcyjnych wymagań w zakresie jakości dostarczonego paliwa. Ze względu na brak technologicznych przeszkód do implementacji silnika w układach typu Power-to-Gas-to-Power (P2G2P), stanowiących technologię o potencjalnie szerokim obszarze zastosowań, badania nad możliwością adaptacji silników tego typu do wykorzystania w układach zasilanych wodorem budzą zainteresowanie zarówno środowisk akademickich, jak i inwestorów. W niniejszej pracy przedstawiono wyniki badań modelowych silnika Stirlinga zasilanego wodorem, odniesione do rezultatów otrzymanych dla analizy analogicznego silnika zasilanego paliwem systemowym w postaci gazu ziemnego. Celem przeprowadzonych badań była identyfikacja wpływu zmiany paliwa na wartości kluczowych, z punktu widzenia aplikacyjności silnika, parametrów operacyjnych. Rezultaty analizy wykazują istotną zmianę parametrów operacyjnych wraz ze zmianą rodzaju paliwa, określając jednocześnie obszary wymagające modyfikacji w celu umożliwienia wykorzystania silnika Stirlinga w układach zasilanych wodorem.
EN
Despite of almost two hundred years of history of research and development in Stirling engine technology, this engine states issue of advanced computational and experimental investigation. However, modern analyses are commonly motivated by the engine’s beneficial ecological characteristics and possibility of its application in variety of technological systems, as well as lack of strict requirements on quality of fuel being supplied. Due to lack of technological reasons, disabling implementation of the Stirling engine in Power-to-Gas-to-Power (P2G2P) units, stating one of areas of greatest potential for modern power engineering, applicability of the engine in power units supplied with hydrogen states matter of interest of both academic circles and investors. In the paper, results of model-based analysis of Stirling engine supplied with hydrogen, referred to data acquired for analogical engine supplied with conventional fuel in the form of natural gas, stating classical fuel for similar engines. The main objective of the research was identification of influence of change in fuel being supplied on values of essential – considering the Stirling engine applicability – operational parameters of the device. Results of the analysis indicate significant change in operational parameters following change in type of fuel, being derived, describing simultaneously fields of that technology requiring reconfiguration in order to enable utilization of Stirling engine in hydrogen-fuelled units.
EN
Is the world’s power engineering at a crossroads? Does the rapid development of new emerging fields such as the Internet of Things, smart city or e-mobility make us take a completely different point of view on the world’s energy future? What are our visions and development forecasts related to this? Who is right, Exxon Mobil Corporation or the visionary investor Elon Musk? The author of this article is trying to find answers to these and many other questions. In the long-term perspective, a transition from centralised power generation to distributed power generation seems to be inevitable, and that is the central message of this article. The article also presents the situation of the Polish power engineering against the background of global trends, as well as proposals for solving the smog problem using anti-smog technologies developed at the Institute of Fluid-Flow Machinery of the Polish Academy of Sciences in Gdańsk and by launching a pilot project that will cover 1,000 households equipped with these technologies. The author and his closest co-workers recommend equipping boilers, including both older and newer ones, with low-power electrostatic precipitators. In this way, one can burn low-quality fuels while keeping the emission of airborne dust at a low level. It is a quick and not pricey solution to the smog problem.
EN
The article presents the current state of possible cooperation and control of energy sources working in the Distributed Generation system. The definition of distributed generation and classification of power sources working in such a system depending on country (which defines it) was presented. Outlined were also opportunities for development of distributed generation in Poland according to provisions of the law.
PL
W artykule przedstawiono stan obecny możliwości pracy i sterowania źródłami energii pracującymi w energetyce rozproszonej (prosumenckiej). Zaprezentowano w jaki sposób definiowana jest energetyka rozproszona w różnych krajach i jaka jest klasyfikacja źródeł rozproszonych. Nakreślone zostały również wynikające z przepisów prawa możliwości rozwoju energetyki rozproszonej w Polsce.
PL
Omówiono charakterystyki kosztowe i techniczno-ekonomiczne występujących rozproszonych źródeł energii elektrycznej
EN
Discussed are cost and technical and economic characteristics of the existing distributed electric energy sources.
11
Content available remote Rozproszona energetyka a ogniwa paliwowe
PL
Celem artykułu jest przedstawienie wyników obecnych badań nad źródłami energii elektrycznej i cieplnej, które to źródła byłyby stosowane w  tzw. energetyce rozproszonej (ang. Distributed Generation - DG). Podstawowym elementem analizy jest porównanie systemów energetycznych opartych o rozproszone wytwarzanie z obecnymi systemami elektroenergetycznym i ciepłowniczymi. Autorzy przedstawili możliwe rozwiązania takich systemów ze szczególnym uwzględnieniem ogniw paliwowych jako przyszłościowego źródła energii elektrycznej i ciepła.
EN
Analyses of energy sources for distributed generation (DG) are presented. Distributed generation is defined as a system build which consist of many small independent energy sources. Comparison between distributed generation and present large centralized facilities is shown and commented (power plant and CHP). Theoretically, it is possible to configure many types of energy source and fuel in the distribution generation. Possible configurations of systems are presented by authors with special focus on fuel cells as a future energy source.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.