Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 7

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  dielectric loss factor
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
In this paper study for wave propagation in non-homogeneous porous plate sample with slowly varyingrefractive indexis presented. It is based on simple symmetricsolution of the wave equation for linearlypolarized electromagnetic wave aligned into the porous plate perpendicularlyto the external surface. Using correct boundary conditions both the transverseelectric (T.E) and transversemagnetic (T.M) modes, named shortly by (T.E.M) mode for electromagnetic wave, are considered. The Wentzel-Kramers-Brillouin (W.K.B.) solutions for symmetric incident irradiation of fixed power generated at the plate surfaceswas obtained. It isdonethe analysis of the reflection and transmission coefficients on the surfaces of plate.
PL
W artykule przedstawiono wyniki badań laboratoryjnych próbek izolacji celulozowo-aramidowej NOMEX®910 impregnowanej estrem syntetycznym MIDEL®7131, w postaci charakterystyk dyspersyjnych pojemności, współczynnika strat dielektrycznych oraz zespolonej przenikalności w zakresie częstotliwości napięcia pomiarowego od 10 mHz do 5 MHz. Celem badań była analiza wpływu stopnia termicznej degradacji składnika celulozowego izolacji na ww. charakterystyki. Wykazano, że wpływ ten jest istotny dla okna częstotliwości od 1 kHz do 400 kHz.
EN
The article presents the results of laboratory tests of samples of cellulose-aramid insulation NOMEX®910 impregnated with the synthetic ester MIDEL®7131, in the form of dispersion characteristics of capacity, loss factor and complex permittivity in the frequency range of the measurement voltage from 10 mHz to 5 MHz. The aim of the research was to analyze the impact of the degree of thermal degradation of the cellulose component of the insulation on the aforementioned characteristics. It has been shown that this influence is significant for the frequency window from 1 kHz to 400 kHz.
PL
Parametrem diagnostycznym izolatorów przepustowych stosowanym standardowo on-line jest pomiar tg𝛿 między punktem pomiarowym P i kołnierzem K. Wykazano, że tg𝛿 nie informuje w sposób dostateczny o stanie technicznym izolatora przepustowego. Polecanym parametrem diagnostycznym on-line izolatora jest prąd upływu 𝐼 mierzony w obwodzie rezystancji 𝑅𝑚 włączonej między punkty P-K. Korzystne jest sumowanie sygnałów prądowych z izolatorów trzech faz. Sumowanie należy realizować na transformatorku (rys. 9). Pomiar prądu sumarycznego 𝐼0 jest prosty w realizacji i wolny od zakłóceń.
EN
The standard diagnostic parameter HV bushings used on-line is the measurement of tgδ between the measuring point P and the flange K. It has been shown that tgδ does not sufficiently inform about the technical condition of the bushing. The recommended on-line diagnostic parameter of the insulator is the leakage current I measured in the circuit of resistance 𝑅𝑚 connected between points P-K. It is advantageous to sum the current signals from the insulators of the three phases. Adding up should be done on a transformer (Fig. 9). Measurement of the summary current 𝐼0 is simple to implement and free from interferences.
EN
The paper presents an automatic system for measuring the moisture content of wood on the basis of loss factor tanδ. The instrument is based on a structure of the non-bridge, quasi – balanced circuit implemented in a program way. The virtual measuring system uses the data acquisition board NI USB-6251 from National Instruments and LabVIEW environment. The preliminary results of experimental studies were compared with the results of the LCR meters Hioki 3522, MOTECH MIC-4090 and meter of wood humidity Powerfix HG00384C.
EN
This paper presents a distributed measuring system for on-line monitoring of dielectric loss factor tan δ, and capacitance of HV apparatus. The method employs the Discrete Fourier Transform (DFT) which is performed on the scaled down analog voltage and current signals obtained using digital signal processing (DSP) technology. The measuring unit of the on-line monitoring system takes a series of measures in the hardware circuit design to improve the effectiveness of the DFT algorithm. The lab test results of measuring unit show that the measuring unit has high precision of measurement based on the DFT method. Field tests at a regional substation to evaluate the insulation of two groups of 220kV current transformer units using the developed system.
PL
W artykule opisano system pomiaru rozproszonego do monitorowania on-line współczynnika strat dielektrycznych i pojemności w aparatach HV. W metodzie wykorzystano Dyskretną Transformatę Fouriera. W celu poprawy dokładności i skuteczności DFT, dokonywana jest seria pomiarów. Wyniki badań laboratoryjnych oraz w rzeczywistej podstacji, wykazały wysoką precyzję rozwiązania.
PL
Tematyka badań związana z rozwojem materiałów elektroizolacyjnych oraz metod diagnostycznych transformatorów elektroenergetycznych jest już rozwijana od wielu lat [1]. Eksploatacja transformatorów, koszty diagnozy oraz napraw są bardzo wysokie, dlatego tak istotne staje się ciągłe udoskonalanie obecnych metod diagnostycznych oraz ciągłe poszukiwanie nowych rozwiązań pozwalających na dokładniejszą prognozę procesów starzeniowych zachodzących w olejach elektroizolacyjnych. Istnieje wiele metod diagnostycznych zarówno pośrednich jak i bezpośrednich wykorzystywanych do badań parametrów elektroizolacyjnych olejów transformatorowych. W niniejszym artykule przedstawiono metodę diagnostyczną wysokonapięciowych układów izolacyjnych opartą na pomiarze tgδ w funkcji częstotliwości. Obiektem badań są przygotowane próbki olejowe o różnym czasie starzenia. Wyniki badań mają posłużyć do weryfikacji poprawności metody pomiarowej, a w przyszłości przyczynić się do budowy modelu służącego weryfikacji wyników pomiarowych związanych z oceną stopnia zestarzenia izolacji olejowych.
EN
The paper presents a diagnostic method of insulating mineral oil systems based on the measurement of dielectric loss factor. The objects of the research are oil samples prepared at different times of aging time. The results will be helpful to creating aging process model, used to verifying measurement results of degradation in mineral insulation oil (aging process) based on measurements of dielectric loss factor.
EN
Analysed is the influence of nanoparticles addition on dielectric properties of a transformer oil. For the exemplary modification of the oil, fullerene C60 is used. Measured are electrical properties of mixtures: conductivity, permittivity, dielectric loss factor and breakdown voltage. It is observed that the C60 addition slightly influences breakdown voltage of mineral oil. Dielectric loss factor can be reduced twice dependently on nanoparticles concentration in oil. The resisitivity and permitivity do not change with the C60 content.
PL
Przedstawiono wyniki analizy wpływu dodatku nanocząstek na właściwości fizykochemiczne oleju transformatorowego. Do modyfikacji oleju użyto fullerenów C60. Przeprowadzono pomiary elektrycznych właściwości cieczy: przewodności, przenikalności, współczynnika strat dielektrycznych oraz napięcia przebicia. Na podstawie wyników stwierdzono, że zawartość C60 w oleju nieznacznie wpływa na jego napięcie przebicia. Współczynnik strat dielektrycznych może maleć około dwukrotnie w zależności od stężenia nanocząstek. Rezystywność i przenikalność nie zmieniają się w zależności od zawartości fullerenów.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.