Content available remote Comparison of two single-solute models of potassium kinetics during hemodialysis
EN
Optimal potassium removal in hemodialysis (HD) is an important but difficult to achieve goal, influenced by numerous factors. Two types of single-solute mathematical models have been previously proposed to assess potassium kinetics in HD: pseudo-one compartment ( p1) and two-compartment models (2c). We compared these two models in simulating potassium kinetics during HD sessions with different treatment settings. After estimation of unknown parameters via fitting to clinical data during 4 h sessions with a dialysate potassium of 2.6 ± 0.6 mmol/L, the models were used to simulate 4 HD sessions for each patient, resulting from the combination of session length (4 h vs. 8 h) and potassium dialysate concentration (2.6 vs. 0 mmol/L). The simulated potassium concentration profiles were similar under different treatment conditions, and predicted potassium removal during the treatments was 77 ± 24 mmol with the standard settings; both increases in session length and potassium dialysate to plasma concentration gradient resulted in a significant increase in potassium removed. Both models indicated similar minimum values of dialysate potassium concentration required to avoid post-HD hypokalemia: 1.18 ± 0.66 mmol/L for 4 h HD and 1.71 ± 0.52 mmol/L for 8 h HD. The models described similar kinetics for potassium during different combinations of treatment settings. Total removal of potassium and minimum dialysate concentration to avoid post-HD hypokalemia, were predicted without significant differences by both models. Although no model has a clear advantage in terms of describing clinical data, our analyses suggest that 2c might offer a better trade-off between physiological accuracy and over-parametrization.
2
Content available Wydzielanie sadzy z olejów przepracowanych
PL
Omówiono wyniki badań czterech sposobów analitycznego usuwania sadzy z oleju silnikowego po eksploatacji. Na wstępie przedstawiono przegląd metod zabezpieczania silnika przed nadmiernym gromadzeniem się sadzy w smarującym go oleju silnikowym. Przyjęto, że do badania jakości eksploatowanego oleju zostanie zastosowania metoda ITN 91.06, oparta na normie ASTM E 2412-04, pozwalająca na ocenę stopnia oksydacji i nitrooksydacji oleju silnikowego. W tym oznaczeniu poważne trudności powoduje obecność dużej ilości sadzy, podnosząc poziom tła w obszarze pomiarowym. Wprawdzie zastosowanie wirowania do usuwania sadzy nie dało oczekiwanych wyników, bowiem nie usunięto całości sadzy z badanego oleju, lecz zmniejszono jej zawartość. Ułatwiło to jednak przeprowadzenie pomiarów, ponieważ zostało obniżone tło widma, związane z obecnością sadzy. Można przypuszczać, że zastosowanie wirówki o wyższym współczynniku rozdziału umożliwi uzyskanie próbek o znacznie mniejszej zawartości sadzy. Metoda dializy pozwoliła na całkowite usunięcie sadzy z próbki, lecz jednocześnie usuwane są substancje wielkocząsteczkowe (np. dodatki), a zatem nie nadaje się ona do przeprowadzenia takiego oczyszczania próbki. Metoda ekstrakcyjna co prawda podobnie pozwala na całkowite usuniecie sadzy, jednak uzyskiwane wyniki pomiarów również są wyraźnie niższe niż w przypadku oznaczenia bezpośredniego. Praktycznie najciekawszym jest sposób wykorzystujący do oczyszczania próbki sorpcję na bibule szklanej, lecz i tu obserwuje się pewne obniżenie mierzonych wartości parametrów oksydacji i nitratacji, czego powodem może być sorpcja części polarnych produktów destrukcji oleju silnikowego na powierzchni szkła lub usuwanej sadzy. Obniżony poziom parametrów oksydacji i nitrooksydacji jest obserwowany przy stosowaniu wszystkich badanych metod usuwania sadzy. Najmniejsze różnice zaobserwowano przy stosowaniu metody wirówkowej, lecz metodą to usuwana jest tylko część sadzy z próbki.
EN
Four analytical methods of soot removing from analytical samples of engine oil in use were tested. The methods of the engine protection against excessive concentration of soot in engine oils by removing this contamination were described at the beginning. It was accepted that the FT-IR spectrometric ITN Method 91.06, based on ASTM E 2412-04 standard, for estimate of used lubricants condition by measurement of oxidation and nitratation levels was applied. In this test the large soot content is cause of serious difficulties because the samples have very low transparency in measured IR region. The use of centrifuge for the soot removing from sample did not give satisfied results because the removing of soot was incomplete, but measurements were easier because the soot background was lowered. The use of higher rpm value will probably give the samples with smaller soot concentration. The dialysis method let to remove the soot from sample completely, but together with it a large molecules from oil (for example additives) were eliminated, and therefore dialyse is not suitable procedure for purifying of sample. The extraction method alike dialysis completely remove the soot, and the results of IR measurements are significantly lower than in case of direct measurement. The sample purification on glass blotting-paper is the most interesting method of soot removing but was observed a small lowering of measuring values too, due to sorption on glass or in soot some polar products of oil degradation. This lowered level of oxygenation and nitration values was observed in samples obtained from all applied methods after removal of soot. The smallest difference was observed in centrifugation method, but this method remove only a part of soot.
EN
Possibilities of the application of dialysate optical absorption at certain wavelenghts for the estimation of dialysis progress are presented. It was also discussed when in the monitoring of waste removal process enzymic solutions should be used.
PL
W pracy przedstawiono możliwości wykorzystania pomiaru absorpcji optycznej płynu dializacyjnego na wybranych długościach fal w celu monitorowania procesu oczyszczania krwi z głównych produktów przemiany materii podczas hemodializy. Wskazano również w jakich przypadkach monitorowanie omawianą techniką wymaga użycia enzymów.
5
Content available remote Application of UV spectrophotometry for monitoring of dialysis progress
EN
Certain possibilities of on-line monitoring of dialysis efficiency with spectrophotometric method are connected not with the detection of urea, which is the most common marker of removed wastes, but with some other substances, also diffusing from blood to dialysate. Spectrophotometric detection of acetic acid and creatynine seems to be better choice for these substances exhibit significant absorption which can be recognized in the dialysate spectrum.
PL
Możliwości monitorowania skuteczności dializy metodą fotometryczną związane są nie z wykrywaniem mocznika, który jest powszechnie używanym markerem procesu, ale z innymi substancjami, które też dyfundują z krwi do dializatu. Spektrofotometryczna detekcja kwasu moczowego i kreatyniny wydaje się być lepszym wyborem ponieważ substancje te wykazują absorpcję, która wyraźnie zaznacza się na widmie dializatu.
6
Content available remote Electroseparation techniques using membranes
EN
The paper presents membrane separation processes involving ion exchange membranes: monopolar electrodi-alysis, bipolar electrodialysis and other electrodialysis-related processes such as diffusion dialysis and Donnan dialysis. The principles of the processes, as well as related phenomena, are described. Major applications of electromembrane processes in water and wastewater treatment and in the recovery of valuable components from industrial wastewater are discussed. On the basis of the literature, it was found that the most important use where electrodialysis applies is production of drinking water from brackish water. Another common application of the process is the recovery of water and valuable metal salts from electroplating rinse water. Of great importance is also diffusion dialysis-widely used process allowing the recovery of some components (especially acids) from industrial wastewater.
PL
W pracy przedstawiono możliwości wykorzystania membran chitozanowych w podstawowych procesach membranowych oraz aktualne trendy dotyczące ich modyfikacji i zastosowania w inżynierii biomedycznej.
EN
Applicability of chitosan membranes in basic membrane processes and recent trends in their modification and application in biomedical engineering are presented in the paper.
EN
Dextran is used as a non-isotopic marker of intraperitoneal volume of dializate useful for the investigation of transperitoneal transport. The initial results of TLC application for the determi11ation of dextran concentration in dialysis solutions in vitro and in witro under conditions of clinical dialysis are demonstrated. The correctness of sample preparatio11 for analysis, the limit as well as the error of determi11ation were estimated.
PL
Dextran zastosowano jako nieizotopowy znacznik objętości wewnątrzotrzewnowej płynu dializacyjnego przydatny do badań transportu przezotrzewnowego. Przedstawiono wstępne wyniki badań nad wykorzystaniem TLC do oznaczania stężenia dekstranu w płynie dializacyjnym in vitro i in vitro, w warunkach klinicznej wymiany dializacyjej . Oceniono poprawność przygotowania próbek do analizy, graniczną oznaczalność i błąd oznaczeń.