EN
Introduction: The use of X-ray equipment for medical diagnostic radiography procedures has increased due to advances and complexity of radiological procedures. Achieving good image quality while keeping exposure of workers, public and patient exposure to an acceptable level has become a prerequisite for the radiology department in order to comply with best international practices. The aim of this study was to undertake quality control measurement of seven (7) diagnostic radiography equipment in the south of Benin, the first of its kind. Material and methods: Multifunction detector (Piranha) and beam alignment test tool were used to perform quality control tests on seven (7) X-ray units. The method used as well as the interpretation of the results was based on the American Association of Physicists in Medicine (AAPM), United States Food and Drug Administration (FDA), Healing Arts Radiation Protection (HARP), Institute of Physics and Engineering in Medicine (IPEM), International Atomic Energy Agency (IAEA) and Canadian Safety code 35 (S.C 35) recommendations. Results: The quality control results showed that all X-ray equipment investigated were within standard limits for accuracy of exposure time below 10 ms; reproducibility of kVp, exposure time and dose output; specific dose-kVp2 linearity; and specific dose-mAs linearity. Five (5) out of seven (7) diagnostic X-ray machines passed quality control tests such as X- ray beam alignment, exposure time above 10 ms and kVp accuracy. One (1) X-ray machine failed the quality control test of beam filtration at 70 kVp and above. Conclusions: The findings of this study have provided baseline data for other radiology departments to embark on similar QA/QC activities, and also explore options for optimization of patient dose. However, there is a need to extend the study to cover more diagnostic X-ray machines throughout the country. It is anticipated that this would ultimately assist in improving radiation protection and safety during medical diagnostic radiological procedures.
2
Content available remote Evaluation of effective dose and entrance skin dose in digital radiology
EN
Background: Ionizing radiation has an indispensable role in diagnostic radiology and clinical treatments. Apparently, medical exposure in diagnostic radiology pertains to be the preeminent man-made source of radiation.
EN
Gafchromic films have been used to measure X-ray doses in diagnostic radiology such as computed tomography. The double-exposure technique is used to correct non-uniformity error of Gafchromic EBT2 films. Because of the heel effect of diagnostic x-rays, ultraviolet A (UV-A) is intended to be used as a substitute for x-rays. When using a UV-A light-emitting diode (LED), it is necessary to determine the effective optimal UV wavelength for the active layer of Gafchromic EBT2 films. This study evaluated the relation between the increase in color density of Gafchromic EBT2 films and the UV wavelengths. First, to correct non-uniformity, a Gafchromic EBT2 film was pre-irradiated using uniform UV-A radiation for 60 min from a 72-cm distance. Second, the film was irradiated using a UV-LED with a wavelength of 353-410 nm for 60 min from a 5.3-cm distance. The maximum, minimum, and mean ± standard deviation (SD) of pixel values of the subtraction images were evaluated using 0.5 inches of a circular region of interest (ROI). The highest mean ± SD (8915.25 ± 608.86) of the pixel value was obtained at a wavelength of 375 nm. The results indicated that 375 nm is the most effective and sensitive wavelength of UV-A for Gafchromic EBT2 films and that UV-A can be used as a substitute for x-rays in the double-exposure technique.