Ograniczanie wyników
Czasopisma help
Autorzy help
Lata help
Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 18

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  dental implants
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
The paper presents an information technology for assessing the degree of engraftment of dental implants in the event of a pathology violation through the use of fuzzy sets, which allows using this method for medical diagnostic tasks. Main scientific results: developed algorithms and mathematical models that formalize the process supporting diagnostic decisions based on fuzzy logic; developed mathematical models of membership functions that formalize the presentation of qualitative and qualitative informational features based on the rules of fuzzy logic, which can be used in information expert systems when assessing the degree of engraftment of dental implants in case of disease with pathological diseases.
PL
W artykule przedstawiono technologię informacyjną do oceny stopnia wszczepienia implantów stomatologicznych u pacjentów z przewlekłą chorobą wątroby za pomocą zbiorów rozmytych, co pozwala na zastosowanie tej metody do medycznych zadań diagnostycznych. Główne wyniki naukowe: opracowano algorytmy i modele matematyczne formalizujące proces wspomagania podejmowania decyzji diagnostycznych w oparciu o logikę rozmytą; opracowano matematyczne modele funkcji przynależności formalizujące reprezentację ilościowych i jakościowych cech informacyjnych opartych na regułach logiki rozmytej, które mogą być wykorzystane w informatycznych systemach ekspertowych do oceny stopnia wszczepienia implantów stomatologicznych u pacjentów z przewlekłą chorobą wątroby.
PL
Celem pracy jest prezentacja możliwości wspomagania stomatologicznych zabiegów implantologicznych nawigacją komputerową. Koncepcja użycia projektowanych na podstawie tomografii komputerowej szablonów chirurgicznych stanowi przyszłość implantologii. Pozycjonowanie implantów do niedawna było czynnością bazującą wyłącznie na intuicji chirurga, który w oparciu o własne doświadczenie i wyobraźnię przestrzenną poszukiwał ich optymalnej pozycji. Wykonanie szablonów chirurgicznych z zastosowaniem oprogramowania komputerowego jest w chwili obecnej coraz częściej stosowaną procedurą, gdyż znacznie skraca czas zabiegu oraz precyzuje pozycjonowanie implantów w stosunku do istotnych elementów anatomicznych, uwzględniając optymalny kształt planowanej konstrukcji protetycznej. Używanie nawigacji implantologicznej nie jest w stanie jednak zwolnić chirurga z należytej czujności i weryfikacji istotnych szczegółów w trakcie przeprowadzanego zabiegu.
EN
The aim of this study was to present the possibility of dental implant surgery supporting by the use of computer navigation. The concept of surgical templates using which are projected on the basis of computed tomography is the future of implant dentistry. Until recently implants positioning was a procedure solely based on surgeon’s intuition. He sought optimal position of implants basing on his own experience and spatial imagination. Currently, performing of the surgical templates by the use of computer software is more frequently applied procedure, because it significantly reduces treatment time and clarifies the positioning of the implants in relation to important anatomical structures taking into account the optimal shape of the planned prosthetic construction. However, using the implant navigation procedure can not release the surgeon from proper vigilance and verification of important details in the course of implantation.
EN
The frequency of complications of dental implantation at the present stage varies from 6% to 23%, what determined the relevance of this examination. The aim of this work is to determine the predictive effectiveness of the development of inflammatory complications of dental implantation on the basis of indicators of lipid peroxidation (POL) of the oral fluid (level of malondialdehyde (MDA) and the activity level of superoxide dismutase (SOD)). We examined 49 patients 25-59 years old which had no traumas, operations and diseases requiring medical rehabilitation, inflammatory disease in the maxillofacial area and the gastrointestinal tract, as well as other factors that can affect qualitative and quantitative content of the oral fluid. These patients underwent delayed dental implantation (one implant in one segment of the jaw). The POL indices were determined twice: before operation of dental implantation and 3 days after operation. The effectiveness of the proposed method was determined in accordance to the clinical and economic studies requirements. Prognostic efficiency in accordance with the procedure of conducting clinical and economic examinations on the basis of MDA level was 78%, and based on the level of SOD activity – 76%, which classifies it as high and allow to reduce the number of complications and diagnostic mistakes including in the planning and execution of invasive procedures associated with the installation of dental implants.
4
Content available remote Possibilities of biocompatible material production using conform SPD technology
EN
Purpose: At present, materials research in the area of SPD (severe plastic deformation) processes is very intensive. Materials processed by these techniques show better mechanical properties and have finer grain when compared to the input feedstock. The refined microstructure may be ultrafine-grained or nanostructured, where the grain size becomes less than 100 nm. One of the materials used for such processes is CP (commercially pure) titanium of various grades, which is widely used for manufacturing dental implants. The article deals with one of the technologies available for the production of ultrafine-grained titanium: Conform technology. CP titanium processed by CONFORM technology exhibits improved mechanical properties and very favourable biocompatibility, due to its fine-grained structure. The article presents the current experience in the production of ultrafine CP titanium using this technology. The main objective of this article is describing the behaviour of CP titanium during forming in the Conform device and its subsequent use in dental implantology. Design/methodology/approach: In the present study, commercially pure Grade 2 titanium was processed using the CONFORM machine. The numerical simulation of the process was done using FEM method with DEFORMTM software. The evaluation was performed by simple tensile testing and transmission electron microscopy. The first conclusions were derived from the determined mechanical properties and based on analogies in available publications on a similar topic. Findings: This study confirmed that the SPD process improves mechanical properties and does not impair the ductility of the material. The CONFORM process enables the continuous production of ultrafine-grained or nanostructured materials. Research limitations/implications: At the present work, the results show the possible way of continuous production of ultrafine-grained or nanostructured materials. Nevertheless, the further optimization is needed in order to improve the final quality of wires and stabilize the process. As these factors will be solved, the technology will be ready for the industry. Practical implications: The article gives the practical information about the continuous production of ultrafine-grained pure titanium Grade 2 and the possibility of use this material for dental implants. Originality/value: The present paper gives information about the influence of the CONFORM technology on final mechanical and structural properties with the emphasis on technological aspects.
EN
Purpose: The paper presents the possibility to improve the mechanical properties of dental implants produced of Ti6Al4V titanium alloy and possibility to use a new method to production those implants. The aim of the study was a comparison of properties of the feed materials, produced and commercial implants made of Ti6Al4V. Design/methodology/approach: The innovative injection methods was used. The comparison of microstructures and microhardness were carried out. Findings: It was shown that the use of new injection methods in the dental implant producing process effects on their structure and thus their mechanical properties. It has been observed that implants manufactured in comparison to commercial implants have a varied structure which is changing from the surface of the implant to its core. These changes are associated with a producing method that ensures very rapid heat dissipation from the surface of the manufacturing element. Research limitations/implications: During the production of the implants, problems have been encountered with keeping the alloy clean may occur. Practical implications: Injection method can be used as a method for commercial production of dental implants. Originality/value: The paper presents the results of microstructure and mechanical properties of dental implants – produced by new injection method.
EN
The article refers to some issues of the mandible reconstruction in the region of chin with the method involving dental implants introduced for teeth restoration. 12 models are created, which take into account three different graft materials (iliac crest, fibula and rib) and two various implant lengths (13 and 18 mm). The authors try to answer the question how the parameters of the introduced implants affect the distribution of the strain intensity in the mandible, both in the implantation area and at its border with autogenous graft. Also, the distribution of equivalent stress in the reconstruction plate and dental implants is analyzed.
PL
Praca dotyczy problematyki rekonstrukcji żuchwy w rejonie bródki z wykorzystaniem metody polegającej na wprowadzeniu implantów stomatologicznych pod odbudowę uzębienia. W artykule stworzono 12 modeli uwzględniających zastosowanie trzech różnych materiałów na przeszczep (kości biodrowej, strzałkowej i żebra) oraz dwie różne długości umieszczonych implantów (13 i 18 mm). Autorzy podjęli próbę odpowiedzi na pytanie, w jaki sposób parametry wprowadzonych implantów wpływają na rozkład intensywności odkształcenia w kości żuchwy w obszarze implantacji oraz na granicy z przeszczepem autogennym. Analizie poddano również rozkład naprężenia zredukowanego w płycie rekonstrukcyjnej oraz implantach stomatologicznych.
PL
W pracy przedstawiona została analiza MES zrekonstruowanej żuchwy wraz z wprowadzonymi implantami stomatologicznymi. Ocena najbardziej korzystnych warunków do powstania prawidłowego zrostu kostnego odbywała się poprzez porównanie otrzymanych wartości intensywności odkształcenia na granicy pomiędzy kością żuchwy a przeszczepem autogennym, z wartościami granicznymi zawartymi w hipotezie stymulatora mechanicznego przebudowy tkanki kostnej.
EN
The aim of work was FEM analysis the case of mandibular reconstruction with use dental implants. The evaluation of bone union process was performed as a comparison of the strain intensity value on the border mandibular – autogenous graft with limit values that are included the hypothesis of a mechanical stimulator remodeling of bone tissue.
PL
Leczenie implantoprotetyczne jest nieodzowną częścią nowoczesnej stomatologii. W celu osiągnięcia stabilnego estetycznie i funkcjonalnie rezultatu implantologia stanowi obecnie bardzo ważną terapeutycznie strategię pozwalającą zastąpić brakujące uzębienie. W obecnych czasach odbudowa braku pojedynczego zęba przy użyciu korony opartej na implancie jest podstawowym wskazaniem terapeutycznym. W pracy przedstawiono 2 przypadki stomatologiczne. Implantolog powinien posiadać strategię leczenia, która oferuje satysfakcjonujące wyniki terapii połączone z wysoką skutecznością i przewidywalnością. Pacjentów zakwalifikowano do analizy na podstawie wywiadu medycznego, badania cznego oraz analizy zdjęć radiologicznych. Badania kliniczne obejmowały aktualny stan, potrzeby lecznicze uzębienia i przyzębia. W badaniach wykorzystano technikę rentgenowską - zdjęcia pantomograficzne oraz tomografię komputerową. Leczenie implantoprotetyczne obejmowało leczenie chirurgiczno-periodontologiczne, wszczepienie implantów, wykonanie uzupełnień stałych pełnoceramicznych. W prezentowanych przypadkach zastosowano implanty XIFNT firmy Biomet 3i oraz implanty S firmy Bego Semados. Badania materiałowe wykonano z wykorzystaniem skaningowej mikroskopii elektronowej oraz profilometrii optycznej. Badania mikroskopowe pokazały jednorodną, pasmową strukturę wszystkich badanych powierzchni. Ich chropowatość powierzchni jest ściśle określona i równomiernie rozmieszczona w celu dobrej osteointegracji. Takie pożądane charakterystyki uzyskano dzięki odpowiednio dobranym i wykonanym technikom piaskowania i trawienia.
EN
Implant-prosthetic rehabilitation has become an indispensable care in modern dentistry. In search for aesthetically and functionally stable result, osseointegrated implants are currently an important strategy for missing teeth replacement. Nowadays, the absence of a single tooth reconstruction with a crown based on implant is the primary therapeutic indication in implant dentistry. The paper presents two clinical cases. Implantologist should have a treatment strategy that offers satisfactory results combined therapy with high efficiency and predictability.The patients were selected on the basis of past medical history, clinical assessment and the analysis of radiographic scans. Clinical assessment included the examination of current state, teeth and peridontium care needs determined based on X-ray technique – pantographic photos, and computed tomography. The implant-prosthetic treatment included surgical-periodontal procedures, implant placement, and dental prostheses – fully ceramic. Implants XIFNT manufactured by Biomet 3i and implants S by Bego Semados were used in the cases discussed. Surface morphology and chemical composition were determined using JSM 7100F scanning electron microscope by JEOL with a resolution of 1.2 nm. The results showed a homogeneous, planar structure of all surfaces investigated. Their surface roughness is strictly defined and uniformly distributed for proper osseointegration. These desirable features were obtained owing to properly selected and applied sand blasting and acid etching techniques.
EN
Purpose: The aim of the paper is to present the method of computer aided planning and manufacturing of a prosthetic suprastructure based on 6 implants in the totally edentulous mandible using digital intraoral scans. Design/methodology/approach: TThe method of computer aided planning and manufacturing of the implantoprosthetic restoration in the completely edentulous mandible using digital scans is presented on the example of a real clinical case of a patient with a significant deficit of alveolar bone qualified for the implant treatment. The abutments and the final fixed metal-ceramic bridge was designed and manufactured only on the basis of digital scanning of the intraoral supporting area instead of using traditional impression materials and trays. Findings: The method of computer-aided design and manufacturing of fixed restorations in the mandible using a digital scan of the supporting area is a powerful technique for improving the treatment process, through which the clinician and the patient may obtain satisfactory results in terms of functionality and aesthetics. Practical implications: The experience gained by the authors of the article in the technique of computer aided designing and manufacturing of fixed bridges on the basis of digital intraoral scans allows for the formulation of rules that must be followed at both clinical and laboratory stages. The properly performed scanning allows to obtain greater precision of the final restoration in terms of fit and occlusal accuracy. Originality/value: This paper presents an original methodology of obtaining information about intraoral configuration of the soft tissues and the position of the implants with the use of digital scanning. This method allows for designing and manufacturing of both the abutments and the final restoration without using impression materials which is especially useful in patients with significant bone loss and the gag reflex.
EN
Purpose: The aim of the paper is to present the own method of design and manufacturing of surgical guides on the basis of cone beam computed tomography (CBCT) scans and three-dimensional models of teeth and soft tissue obtained from impressions or intraoral optical scans, which are possible to use during surgical implant placement. Design/methodology/approach: The method of designing and manufacturing of surgical guides was developed on the basis of real clinical data coming from patients with severe bone deficit qualified for implantological treatment. The model of bone and virtual model of soft tissues were combined together. The project of the prosthetic restoration imposed on the virtual model of the bone was used to plan the position of the implants. The final surgical guide was manufactured with the use of a CNC milling machine. Findings: The method enables planning of the implant position based on two combined models of the bone and soft tissues and allows to design and manufacture a surgical guide. Thus, it becomes possible to place the implants in the bone of the patient during a surgical procedure in a preplanned position. Practical implications: Thanks to the method of designing and manufacturing of surgical guides a range of clinical tasks in preparation of the guides is restricted to registration of the intraoral situation, taking of CBCT scans of the bone and determination of the type of the prosthetic restoration. Properly made surgical guides allow to shorten the time of the surgical procedure and carry it out in a minimally invasive manner. Originality/value: This paper presents an original method of designing and manufacturing of surgical guides. This allows for precise planning of the position and the number of implants and the transfer of these data into the mouth of a patient during the surgery without the use of commercially available closed software.
11
Content available remote Comparative 3D FEM analysis of three different dental implant shapes
EN
This paper presents the results of numerical modeling using the finite element method of three implants. Geometric models of individual parts of the analyzed system (implant, abutment and screw) and the standard models of the bone and the crown were built in the Ideas NX environment. On the basis of real geometric models the fully three-dimensional numerical models were built. The calculations for different implant systems were carried out using MARC/Mentat commercial software. The numerical models of each system consist of five deformable bodies being connected to each others. Modeling was carried out in two stages. The first stage includes the modeling of the stresses in the bone-implant-abutment-screw assembly. The preload of models was set so that the axial stress in the screw core is equal to 75% of yield stress of material from which the screw was made. In the second stage the model with assembly stresses was being loaded with oblique force on the crown with values in the range from 0 to 250 N. An analysis and comparison of stress distributions and values of stresses in analysed implant systems were carried out. This investigation shows the meaningful influence of the shape of implant of an abutment on distribution and values of stress, load capacity of individual implant systems, and furthermore, stress in osseous tissue.
PL
W pracy przedstawiono wyniki modelowania numerycznego MES trzech systemów implantologicznych. Modele geometryczne poszczególnych części badanych układów (implant, łącznik, śruba) oraz standardowe modele kości i korony zostały utworzone w programie Ideas NX. Na podstawie modeli geometrycznych zbudowano trójwymiarowe modele numeryczne badanych systemów. Symulacje numeryczne poszczególnych systemów implantologicznych przeprowadzono za pomocą komercyjnego oprogramowania MARC/Mentat. Model numeryczny każdego systemu składał się z pięciu ciał odkształcalnych połączonych ze sobą. Analizę numeryczną dla poszczególnych systemów implantów przeprowadzono w dwóch etapach. Pierwszy obejmował modelowanie naprężeń montażowych. Obciążenie montażowe było zadawane w taki sposób, aby naprężenia osiowe w rdzeniu śruby wynosiły 75% granicy plastyczności materiału, z którego jest ona wykonana. W drugim etapie model ze wstępnymi naprężeniami montażowymi był obciążany na koronie ukośnie siłą w zakresie wartości od 0 do 250 N. Dokonano analizy oraz porównania rozkładów i wartości naprężeń występujących w badanych systemach implantologicznych. Badania wykazały znaczący wpływ kształtu implantu oraz łącznika na rozkład i poziom naprężeń oraz nowości poszczególnych systemów implantologicznych, a tak że na naprężenia w tkance kostnej.
PL
Celem pracy była charakterystyka współczesnych poglądów na zagadnienie warstwy wierzchniej i jej roli w procesie osteointegracji wszczepów stomatologicznych. Przedstawiono parametry powierzchni, które bezpośrednio wpływają na inicjację procesu integracji implantu oraz jego późniejsze funkcjonowanie w organizmie. Szczególną uwagę poświęcono zagadnieniu struktury powierzchni implantów dentystycznych oraz metodom modyfikacji umożliwiającym funkcjonalizację powierzchni z wykorzystaniem biomolekuł. Współczesne kierunki inżynierii powierzchni skupiają się na zwiększeniu biozgodności materiałów metalicznych i intensyfikacji procesów osteointegracji w oparciu o zasady biomimetyki. Liczne badania in vitro, in vivo oraz wstępne badania kliniczne wskazują, że uzyskanie nanotopografii zapewnia szybszą osteointegrację implantów dentystycznych w porównaniu ze standardowymi wszczepami o powierzchni mikrostrukturalnej. Zastosowanie biomolekuł takich jak: kolagen, sekwencje peptydowe lub czynniki wzrostu przyspieszają procesy wgajania się implantów, co zostało również potwierdzone w badaniach in vitro oraz in vivo. W pracy poruszony również został problem biofilmu bakteryjnego, który jest szczególnie zauważalny w implantologii stomatologicznej. Zjawisko kolonizacji powierzchni abiotycznych przez mikroorganizmy jest szczególnym problemem implantologii stomatologicznej. Ocenia się, że powstający na powierzchni implantu biofilm bakteryjny jest jedną z najczęstszych przyczyn utraty wszczepu. Dlatego też obserwuje się dążenia do opracowania nowych metod walki z zakażeniami okołowszczepowymi, wśród których szczególną uwagę poświęca się odpowiedniej modyfikacji warstwy wierzchniej. Obecnie uważa się więc, że oprócz osiągnięcia dobrej osteointegracji, biomateriały powinny wykazywać właściwości umożliwiające zahamowanie adhezji bakterii, a tym samym formowania biofilmu, który może być przyczyną utraty implantu.
EN
The aim of this work is to present modern directions in the field of surface layer and its role in the process of dental implants osseointegration. The subject of analysis were parameters of the surface that directly initiate process of integraton of the implant with the tissue and its further functioning in the body. The thorough attention was paid to the micro- and nanostructure of dental implant surface and the methods of its modification using biomolecules in order to make the implant functional. Another subject of the study was bacterial biofilm formation, which is particularly noticeable and dangerous in dental implantology. Having read the literature about modifications of titanium biomaterials surface, it can be concluded that modern trends in surface engineering focus on maximizing the biocompatibility of implants and their osseointegration on the basis of biomimetics. Numerous in vitro, in vivo tests and clinical research suggest that using nano-topographic materials results in faster osseointegration of dental implants in comparison with standard microstructure implants. Furthermore, introducing such biomolecules like collagen, peptide sequences or growth factors accelerate the implant healing process, which has been proven by in vitro and in vivo tests. The long-term implant functionality might also depend on using additional agents which prevent bacterial adhesion and subsequent formation of biofilm, leading to the implant loss.
EN
The paper presents results of microscopic observations of selected porcelain bridges prepared on metallic base. The aim of microscopic observations was the identification of example wear types which have appeared during dental prosthetic bridges exploitation. The main attention was directed to wear forms that are quite often present in case of such prosthetic elements. The wear types comparative analysis was evaluated. The most frequent types of wear are: material's cracking, abrasive wear. Also, the metal corrosion and wear by dental plaque at prosthetic bridge surface were observed.
PL
W leczeniu ubytków uzębienia z zastosowaniem tytanowych implantów stomatologicznych obserwuje się powikłania o charakterze mechanicznym. Celem analiz numerycznych implantów z zastosowaniem MES było określenie przyczyny występowania powikłań oraz zaproponowanie rozwiązań pozwalających na ich unikanie, możliwych do zastosowania w praktyce stomatologicznej oraz w procesie projektowania implantów.
EN
Various mechanical complications can be obsen/ed in a treatment technique performed with the use of titanium implants. The main goal of the presented study was to find out the reasons of the complications and to suggest how to avoid them. Complex FE analysis proced:"res, which can be used in dental implants designing and manufacturing processes, were devised. The practical conclusions and recommendations for dental surgeons were formulated as well.
PL
Różne rodzaje warstw węglowych otrzymanych różnymi sposobami, między innymi warstwy diamentopodobne (DLC) oraz warstwy nanokrystalicznego diamentu (NCD) otrzymane w procesie rozkładu metanu w polu wysokiej częstotliwości RFPACVD, są w wysokim stopniu biokompatybilne. W zależności od parametrów nanoszenia, różnią się one bio-fizycznymi oraz mechanicznymi właściwościami, DLC są amorficzne i zawierają około 60% diamentu oraz 40% grafitu, NCD składają się niemalże całkowicie z czystego diamentu. Zastosowanie warstw węglowych w medycynie jest znane od wielu lat. Prace nad implantami stomatologicznymi rozpoczęły się ponad dziesięć lat temu.
EN
Different kinds of carbon coatings, obtained by different methods are highly biocompatible, among them both diamond-like carbon (DLC) and nanocrystailine diamond (NCD) coatings obtained with the radio frequency plasma activated chemical vapour deposition (RFPACVD) process. They have different bio-physical and mechanical properties, in dependence of the parameters of deposition; DLC are amorphous coatings consisting of about 60% diamond and 40% graphite, NCD contains almost pure diamond. The application of carbon coatings in medicine is investigated for many years. Research on dental implants has begun more that decade ago. Otborska and all has explained the good mechanical properties of amorphous carbon coatings - DLC. Amorphous carbon (a-C) coatings, obtained by RFPACVD method, were deposited on implants used in maxillofacial surgery and on the dental prostheses. In all cases the substrate was the medical steel AISI 316L. After that the coating was investigated by Auger electron spectroscopy (AES). AES results show that the surface layer consists of carbon and the interface layer consisting of the substrate carbides (i.e. Cr, Ni, Mo, Fe) makes the coating more adhesive and improves its quality. However, the next generation coatings-NCD, improved in many ways the mechanical properties of the first carbon coatings. Nanocrystailine diamond coatings (NCD), posses the unique bio-medical and mechanical properties and so have found many applications in medicine. NCD is about 1mim thin coating with a very high adhesion to substrate thanks to the interface layer containing substrate carbides. It consists almost pure diamond, the crystals are of the sizes of nanometers. The small amount of graphite, on the grain baundries, even improves the mechanical quality of the coating, it is less brittle. NCD can be coated on different materials, such as titanium and its alloys or medical steel AISI316L, especially interesting are its applications as the coatings for medical implants. Investigations, lasting for many years, show the high biocompatibility of NCD and its good mechanical and physico-chemical properties, it is also resistant to bacterial colonization. Nanocrystailine diamond is also used as the coating for artificial heart valve because of its heamocompatibility and for dental implants. Dental implants have been coated with nanocrystailine diamond by RFPACVD method. Then their surface was analyzed by Raman Spectroscopy, Atomic Force Microscopy and Scanning Electron Microscopy. The good quality, uniform NCD coating, obtained on the dental implants surface, is a promising material in this area of research.
PL
Wykonanie dobrej protezy jest uzależnione od prawidłowości postępowania w części klinicznej i laboratoryjnej podczas jej wykonywania. Współczesna protetyka stomatologiczna dysponuje szeroką gamą materiałów, które mogą być wykorzystane w rehabilitacji układu stomatognatycznego. Jednak częste uszkodzenia płyt protez mogą świadczyć o zbyt małej wytrzymałości mechanicznej tworzywa akrylowego, z którego są wykonywane. W pracy omówiono rodzaje uszkodzeń, ich przyczyny oraz możliwości wzmocnienia akrylu.
EN
Successful construction of a good prosthesis depends on appriopriateness of clinical and laboratory procedures while working on the prosthesis. From a wide range of materials available for the purpose of modern dentistry prosthetic many materials can be used in the course of rehabilitation stomathognatic system. However, frequent damages of prosthesis plates may prove insufficient mechanical strength of acrylic material used for prosthesis construction. The article depicts the types of damages, the damage causes and possible solutions of acrylic material strength improvement.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.