The major reasons that cause the damage of damper bars in the leeward side are found in this paper. It provides a route for the structure optimization design of a hydro generator. Firstly, capacity of a 24 MW bulb tubular turbine generator is taken as an example in this paper. The transient electromagnetic field model is established, and the correctness of the model is verified by the comparison of experimental results and simulation data. Secondly, when the generator is operated at rated condition, the eddy current density distributions of damper bars are studied. And the asymmetric phenomenon of the eddy current density on damper bars is discovered. The change laws of the eddy currents in damper bars are determined through further analysis. Thirdly, through the study of eddy current distributions under different conditions, it is confirmed that the stator slots and armature reaction are the main factors to affect the asymmetric distribution of the eddy current in damper bars. Finally, the studies of the magnetic density distribution and theoretical analysis revealed the asymmetric distribution mechanism of eddy current density.
EN
In order to research the losses and heat of damper bars thoroughly, a multislice moving electromagnetic field-circuit coupling FE model of tubular hydro-generator and a 3D temperature field FE model of the rotor are built respectively. The factors such as rotor motion and non-linearity of the time-varying electromagnetic field, the stator slots skew, the anisotropic heat conduction of the rotor core lamination and different heat dissipation conditions on the windward and lee side of the poles are considered. Furthermore, according to the different operating conditions, different rotor structures and materials, compositive calculations about the losses and temperatures of the damper bars of a 36 MW generator are carried out, and the data are compared with the test. The results show that the computation precision is satisfied and the generator design is reasonable.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.