Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Powiadomienia systemowe
  • Sesja wygasła!
  • Sesja wygasła!

Znaleziono wyników: 5

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  czujniki tekstylne
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
The unique characteristic of the electroconductive fabric-based sensor is its ability to generate an electric signal directly in response to external stimuli. A fabric-based layer can protect objects and simultaneously monitor changes in resistance. It was found that the electrical resistance of fabric increases with increased mechanical damage to its surface. As the resistance increases, the fabric loses its protective properties, which may damage the object. The analysis of static characteristics enabled the selection of fabrics characterised by the widest range of electrical resistance, which results in a desirable higher sensitivity factor of the fabric-based sensor.
PL
Unikalną cechą sensora na bazie tkaniny elektroprzewodzącej jest jego zdolność do generowania sygnału elektrycznego bezpośrednio w odpowiedzi na bodźce zewnętrzne, np. uszkodzenia mechaniczne. Warstwa tkaniny może chronić obiekty i jednocześnie monitorować zmiany rezystancji. Stwierdzono, że rezystancja elektryczna tkaniny wzrasta wraz ze wzrostem uszkodzeń mechanicznych jej powierzchni. Wraz ze wzrostem oporu tkanina traci swoje właściwości ochronne, co może skutkować uszkodzeniem obiektu. Analiza charakterystyk statycznych umożliwiła wybór tkanin charakteryzujących się najszerszym zakresem rezystancji elektrycznej, co skutkuje większą czułością sensora.
PL
Rozwój tekstroniki, czyli połączenia elementów elektronicznych z produktami tekstylnymi, pozwolił na pomiar rytmu oddechowego za pomocą czujników tekstylnych. Pomiar opiera się na zmianach odporności dzianiny wykonanej z przewodzących elektrycznie nici, zintegrowanych z ubraniem. Badania przedstawione w tym artykule zostały wykonane w celu wybrania optymalnego rodzaju ściegu stosowanego do dziania czujnika rytmu oddechowego. Badania przeprowadzono na próbkach wykonanych z różnych rodzajów ściegów. Pomiary rezystancji na poszczególnych próbkach przeprowadzano podczas ich cyklicznego wydłużania i kurczenia. Dokonano wyboru odpowiedniego ściegu dla zapewnienia stabilności i niezawodności pomiarów.
EN
The advances in textronics and miniaturization of textile sensors result in their potential use as elements of an innovative system for measuring the vital functions of young children. An important parameter in the proper diagnosis of the state of health of an children is respiration. Its dysfunction may be associated with asthma and colds or cause other life/health threatening complications, including the exclusion of sleep apnea. One of the important functions of this system is the measurement of respiratory rhythm, which is based on the variations in the resistance of a knitted fabric made of electrically conductive yarns, integrated into baby underwear. The subject of investigation are textile sensors to measure respiratory rhythm of small children, which were fabricated from electro-conductive yarn. The sensors were made by knitting in several ways of ribbing. The research presented in this article was carried out to select the optimum type of stitch used for knitting. The tests were made on five samples based on different types of stitches. Resistance studies of individual samples were performed during their stretching. The properties of the respiratory rate sensor depend on the type of the applied stitch. Choose of the right method ensures that the sensor works correct for a long t ime. The guidelines for selection of suitable stitches for stability and reliability of measurements were proposed.
3
Content available remote Development Of Test Rig System For Calibration Of Temperature Sensing Fabric
EN
A test rig is described, for the measurement of temperature and resistance parameters of a Temperature Sensing Fabric (TSF) for calibration purpose. The equipment incorporated a temperature-controlled hotplate, two copper plates, eight thermocouples, a temperature data-logger and a four-wire high-resolution resistance measuring multimeter. The copper plates were positioned above and below the TSF and in physical contact with its surfaces, so that a uniform thermal environment might be provided. The temperature of TSF was estimated by the measurement of temperature profiles of the two copper plates. Temperature-resistance graphs were created for all the tests, which were carried out over the range of 20 to 50°C, and they showed that the temperature and resistance values were not only repeatable but also reproducible, with only minor variations. The comparative analysis between the temperature-resistance test data and the temperature-resistance reference profile showed that the error in estimation of temperature of the sensing element was less than ±0.2°C. It was also found that the rig not only provided a stable and homogenous thermal environment but also offered the capability of accurately measuring the temperature and resistance parameters. The Temperature Sensing Fabric is suitable for integration into garments for continuous measurement of human body temperature in clinical and non-clinical settings.
PL
Obecnie coraz szersze zastosowanie znajduje monitorowanie i/lub ocena predyspozycji i stanu psychofizycznego osób mających podjąć wybrane ważne zadania lub je realizujące. Obserwuje się zatem szybki rozwój metod badawczych i narzędzi, które mogą być stosowane w systemach monitorowania różnych parametrów psychofizycznych. W artykule dokonano przeglądu nieiwazyjnych metod pomiaru reakcji galwaniczno-skórnej i badań utlenowania krwi z wykorzystaniem czujników klasycznych i zintegrowanych z ubraniem.
EN
Now-a-day more and more applications are devoted to monitoring and/or evaluations of predispositions and psychophysical constitution of persons planning to undertake some specific activities or performing the activities. Hence, a fast development of methods and tools that can be used in monitoring systems of different psychophysical parameters is observed. In this paper non-invasive methods of noninvasive methods of measurements of galvanic skin response oxygen blood saturation based on wearable sensors was reviewed.
EN
The aim of this paper is to present research work into designing prototype textile sensors devoted to measuring a human physiological signal, the frequency of breathing. These sensors may be used in medical applications or for firemen’s protective clothing. The aim of our work was to design a textile sensor which could be easily included in clothing structures. The preliminary research into the sensorial materials is described in this paper.
PL
Prezentowana praca ma na celu przedstawienie prototypowych konstrukcji sensorów tekstylnych do pomiaru częstotliwości oddechu, jednego z najważniejszych fizjologicznych sygnałów człowieka. Sensory takie mogą być użyte w aplikacjach medycznych lub też w strażackiej odzieży ochronnej. Istotną częścią pracy jest opracowany sensor tekstylny, który w łatwy sposób może być zaimplementowany w strukturę odzieży. Wstępne wyniki badań nad materiałami sensorycznymi zostały przedstawione w artykule.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.