Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Powiadomienia systemowe
  • Sesja wygasła!
  • Sesja wygasła!
  • Sesja wygasła!
  • Sesja wygasła!
  • Sesja wygasła!

Znaleziono wyników: 3

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  czujnik kapilarny
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
Progress in modern engineering devices favours the development of independent computer systems of intelligent change management of operational characteristics of construction facilities. The article deals with the continuous control system (monitoring) of the soil moisture. The capillary sensor applied provides a far higher accuracy in determining the moisture than it is achieved by discrete determination of soil electrical characteristics which depend on the concentration and proportion of salts dissolved in the soil as well as the particle-size distribution. A flowchart of the diagnostic system was developed; it does not only transfer the data from the sensors, processes them and informs the operator, but also gives the possibility of autonomous inclusion of mechanisms to eliminate the emerged damages. Thus, while monitoring the soil moisture of hillsides, embankments and cuts slopes it prevents their shifts and other damages.
PL
Prezentowana praca dotyczy zagadnień konstrukcji głowicy czujnika do klasyfikacji właściwości użytkowych biopaliw ciekłych przeznaczonych dla silników wysokoprężnych. Ze względów praktycznych, badanie właściwości olei powinno być wykonywane w jednorazowym, tanim naczyniu. Jako wzmiankowane naczynie celowym wydaje się zastosowanie kapilar optycznych. Umożliwiają one automatyczne wprowadzenie cieczy do wnętrza kapilary i badania optyczne cieczy z zastosowaniem przejść fazowych gaz - ciecz oraz fluorescencji. Analiza przejścia fazowego umożliwia określenie właściwości użytkowych paliwa tj. energii potrzebnej do wytworzenia fazy gazowej jak i szybkości przejścia paliwa w fazę gazową. Wobec wysokich temperatur wrzenia olei i estrów pochodzenia roślinnego wynoszących od około 200 do 360°C oraz bezkontaktowego transferu ciepła do cieczy znajdującej się w kapilarze, istotnym zagadnieniem okazało się opracowanie właściwego mikrogrzejnika. Do tego celu zastosowano technologię hybrydową i węgliko-krzemową. Wykonano i testowano dwa typy łóż głowicy oraz dwa typy optrod. Przeprowadzone badania głowicy pokazały, że zakładana klasyfikacja paliw dla silników wysokoprężnych w wykonanej głowicy jest możliwa i bazuje na zakresie czasów przejścia fazowego cieczy w gaz i szybkości narastania fazy gazowej.
EN
The paper presents the constructions of a low-cost disposable optrode for multiparametric classification of bio-diesel fuels. The capillary optrode can be used in the liquid-gas phase transition classification mode and the fluorescence classification mode. The liquid-gas phase transition classification can be correlated with the evaporation energy of the liquid sample and with its evaporation rate. Those parameters are indirectly connected with fuel usability in diesel engines. This type of bio-diesel fuel classification requires use of high temperatures between 200°C and 360°C, depending on the type of fuel to be analyzed. The heater operating temperature must be greater than that because of non contact heat transfer between the heater and the optrode. A suitable micro-heater using SiC has been designed and evaluated. Two versions of the sensor head base that position the optrode in relation to auxiliary optical fibers and the micro-heater has been evaluated, as well as two versions of optrodes. In conclusion the classification of bio-diesel fuels was proven possible based as two major parameters on the time needed for vapor phase creation in the liquid and the speed of vapor volume increase.
PL
Praca dotyczy zadania 5 - "Wykonanie wieloparametrycznego klasyfikatora właściwości użytkowych biopaliw ciekłych" projektu InTechFun. Celem zadana jest wykonanie wzmiankowanego klasyfikatora charakteryzującego się wymienną optrodą oraz niskim czasem i kosztem jednostkowej klasyfikacji. Prezentowany materiał pokazuje zgodną z charmonogramem realizację dwu punktów kontrolnych, tj: D5.1 - "Seria bazowych struktur hybrydowych głowicy" oraz D5.2 - "Seria struktur światłowodowych konwertujących promieniowanie" oraz pokazuje osiągnięcie kamienia milowego K5.4 - "Identyfikacja optoelektronicznych charakterystyk sprzężenia modów dziurawych" zachodzących dla 24 i dla 30 miesiąca projektu.
EN
The paper concerns 5-th task "Multiparametric classificator of liquid biofuels parameters" of InTechFun projects. The aim of the task is elaboration of mentioned classificator that is characterized by disposable capillary optrode and thereforo low cost and short time of single classification. The paper presents that two control pionts D5.1 "Hybrid head" and D5.2 "capillary structures of light convertion" of the task 5 are done in accordance with harmonogram. The paper presents also the milestons K5.4 "Optoelectronic characteristic of hole modes identification" realization.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.