Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Powiadomienia systemowe
  • Sesja wygasła!
  • Sesja wygasła!
  • Sesja wygasła!
  • Sesja wygasła!
  • Sesja wygasła!
  • Sesja wygasła!

Znaleziono wyników: 8

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  czujnik elektrochemiczny
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
In recent years the monitoring of air quality using cheap sensors has become an interesting alternative to conventional analytical techniques. Apart from vast price differences conventional techniques need to be performed by the trained personnel of commercial or research laboratories. Sensors capable of measuring dust, ozone, nitrogen and sulphur oxides, or other air pollutants are relatively simple electronic devices, which are comparable in size to a mobile phone. They provide the general public with the possibility to monitor air quality which can contribute to various projects that differ in regional scale, commercial funding or community-base. In connection with the low price of sensors arises the question of the quality of measured data. This issue is addressed by a number of studies focused on comparing the sensor data with the data of reference measurements. Sensory measurement is influenced by the monitored analyte, type and design of the particular sensor, as well as by the measurement conditions. Currently sensor networks serve as an additional source of information to the network of air quality monitoring stations, where the density of the network provides concentration trends in the area that may exceed specific measured values of pollutant concentrations and low uncertainty of reference measurements. The constant development of all types of sensors is leading to improvements and the difference in data quality between sensors and conventional monitoring techniques may be reduced.
2
PL
W artykule przedstawiono opis budowy oraz badania modułu czujników wielu gazów substancji chemicznych. Moduł jest w stanie wykrywać 11 różnych substancji w stanie gazowym jednocześnie i liczba ta może zostać zwiększona w miarę potrzeb. Moduł został zaprojektowany i zbudowany jako urządzenie do zainstalowania na mobilnych platformach bezzałogowych w zastosowaniach antykryzysowych.
EN
The paper describes the construction and the results of investigations of the multigas module of chemical contaminants sensors. The module is able to detect 11 different volatile chemical agents simultaneously and this number can be increased if needed. The module was designed and built as a device installed on mobile unmanned platform for anti-crisis application.
PL
W pracy przedstawiono prototypowy, laboratoryjny, elektrochemiczny czujnik do oznaczania par benzaldehydu w argonie. Cieczą jonową testowaną jako elektrolit i środowisko reakcji redox była: bis(trifluorometylosulfonylo) i midek 1-butylo, 3-metyloimidazolinowy ([BMIM][Tf₂N]). W pomiarach użyto komercyjnych elektrod firm: DropSens Co. i BVT Technologies. Walidacji poddano dwa parametry metrologiczne czujnika: granicę wykrywalności i czułość.
EN
The paper presents a laboratory prototype of an electrochemical sensor for measurements of benzaldehyde vapor in argon. The following ionic liquid was tested as the electrolyte and redox reaction environment: 1-butyl 3-methylimidazolium bis (trifluoromethanesulfonyl)imide ([BMIM][Tf₂N]). The measurements used commercial electrodes company DropSens Co. and BVT Technologies. Two metrological parameters of the sensor have been subjected to validation: limit of detection and sensitivity.
PL
W artykule przedstawiono wyniki pracy polegającej na wykonaniu przenośnego urządzenia do pomiaru śladowych ilości tlenku węgla. W urządzeniu zastosowano wysokiej klasy, elektrochemiczny czujnik do pomiaru tlenku węgla firmy Figaro oraz mikrokontroler sterujący urządzeniem. Urządzenie posiada możliwość kalibracji oraz odczytu wskazań na lokalnym wyświetlaczu LCD. Przeprowadzono badania czujnika oraz urządzenia w celu weryfikacji poprawności jego działania. Oceniona została niepewność pomiarów wykonywana urządzeniem.
EN
The paper presents the construction of a portable device for measuring low concentration of carbon monoxide. The device uses high-end, an Figaro's electrochemical sensor for measuring carbon monoxide and microprocessor control unit. The device allows to calibrate and read values on the local LCD display. Tests of the device and the sensor were performed. Verified proper operation of the device. The uncertainty of measurement device was assessed.
5
Content available remote Application of electrochemical sensors in determination of selected drugs
EN
Precise and cheap methods for fast detection of drugs for the purposes of administration of appropriate medication are of paramount importance in clinical practice. Nowadays, many pharmaceutics with a high toxicity and narrow margin of safety are applied, so they should be delivered very precisely. Electrochemical methods have been used to determine the concentration of benzodiazepines, phenothiazines and paracetamol types of drugs. These drugs were widely tested, and their electrode reactions, dependences on the medium parameters and metabolism are known. These data may be the basis for the development of biosensors for the above mentioned drugs.
EN
The performance of zirconia-based electrochemical sensor for CO2 monitoring is described. The basic components of the sensor include yttria-doped cubic zirconia as a solid electrolyte and a mixture of carbonates as a CO(2) sensing material. In the range of 12-18 ppm of CO(2) the sensor's response time at 773 K is about 90 s. The sensor exhibits stable performance characteristics within 3-4 months. It is shown that sensor performance is determined by the formation of an ionic bridge that is formed during a special activation procedure.
EN
The factors influencing the behaviour of the modified-with-porphyrinic-polymer NO sensor are discussed. The interfering role of nitrites for NO determiantion is illustrated with the results of amperometric experiments.
PL
Praca ukazuje podstawowe czynniki, które wpływają na pracę elektrochemicznego czujnika tlenku azotu modyfikowanego polimerem porfirynowym. Szereg amperometrycznych eksperymentów przeprowadzonych w roztworach azotynów obrazuje skalę wpływu tych anionów na odpowiedzi prądowe sensora tlenku azotu.
8
Content available remote Determination of chloramines in aqueous solutions. The NCl3 sensor
EN
Reactions of sodium chlorate (I) and NH' carried out in aqueous solutions produce mono-, di- and trichloramine. The stability of the products of this reaction is strongly pH and time dependent. Electrochemical properties of chloramines have been investigated and compared with their spectrophotometric behaviour. Mono- end dichloramine are reduced at Pt electrodes in single, irreversible peaks. The electrode processes of NCl(3) occur in the region of Cl(-) oxidation, and the whole system behaves reversibly. The formation of NCl(3) has been observed by using biamperometry. This method has been used for determination of NCl3 concentration in synthetic samples.
PL
Produktami reakcji chloranu (I) sodu z jonami amonowymi w roztworach wodnych są mono-, di- i trichloroamina. Względne stężenia tych związków silnie zależą od pH i czasu reakcji. Zbadano procesy elektrodowe chloroamin i stwierdzono, że na elektrodzie platynowej mono- i źdichloroamina ulegają jednoetapowej i nieodwracalnej redukcji. Trichloroamina (NCl3) redukuje się w obszarze potencjałów gdzie obserwuje się utlenianie jonów Cl i w efekcie cały proces elektrodowy ma charakter odwracalny. Tworzenie NCl3 obserwowano za pomocą amperometrü z dwiema elektrodami spolaryzowanymi. Metodę tę zastosowano do oznaczania stężenia NCl3 w próbkach syntetycznych.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.