Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 8

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  czujnik chemiczny
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
A number of recent terrorist attacks make it clear that rapid response, high sensitivity and stability are essential in the development of chemical sensors for the detection of chemical warfare agents. Nerve agent sarin [2-(fluoro-methyl-phosphoryl) oxypropane] is an organophosphate (OP) compound that is recognized as one of the most toxic chemical warfare agents. Considering sarin’s high toxicity, being odorless and colorless, dimethyl methylphosphonate (DMMP) is widely used as its simulant in the laboratory because of its similar chemical structure and much lower toxicity. Thus, this review serves to introduce the development of a variety of fabricated chemical sensors as potential sensing materials for the detection of DMMP in recent years. Furthermore, the research and application of carbon nanotubes in DMMP polymer sensors, their sensitivity and limitation are highlighted. For sorption-based sensors, active materials play crucial roles in improving the integral performances of sensors. The novel active materials providing hydrogen-bonds between the polymers and carbon nanotubes are the main focus in this review.
PL
Przeprowadzone w ostatnich latach liczne ataki terrorystyczne jasno wskazują, że w wypadku czujników do wykrywania chemicznych środków bojowych są niezbędne: ich wysoka czułość, szybka reakcja i stabilność. Środek paralityczno-konwulsyjny sarin (2-fluorometylofosforylooksypropan) to związek fosforoorganiczny (OP) uznawany za jeden z najbardziej toksycznych dostępnych chemicznych środków bojowych. Ze względu na to, że jest on bezwonny, bezbarwny, a ponadto bardzo toksyczny, w badaniach laboratoryjnych szeroko stosuje się jego symulator – metylofosfonian dimetylu (DMMP), o podobnej strukturze chemicznej i znacznie mniejszej toksyczności. W artykule przedstawiono rozwój technologii czujników chemicznych do wykrywania gazu DMMP. Omówiono badania dotyczące wykorzystania kompozytów polimerowych z udziałem nanorurek węglowych w czujnikach gazu DMMP. W wypadku czujników, w których wykorzystuje się zjawisko sorpcji, kluczową rolę w poprawie ich wydajności odgrywają materiały aktywne. W niniejszym przeglądzie skupiono się na nowatorskich materiałach aktywnych, w których występują wiązania wodorowe między polimerem a nanorurkami węglowymi.
EN
A sensitive, selective and reliable sensing techniques for ammonia (NH3) gas detection have been highly demanded since NH3 is both a commonly utilized gas in various industrial sectors, and considered as a toxic and caustic agent that can threat human health and environment at a certain level of concentrations. In this article, a brief on the fundamental working principles of sensor specifications of the analytes detection techniques relying has been reviewed. Furthermore, the mechanism of NH3 detection and recent progress in the development of advanced carbon nanotubes (CNTs)-based NH3 gas sensors, and their performance towards the hybridization with the conductive polymers was comprehensively reviewed and summarized. Finally, the future outlook for the development of highperformance NH3 sensors was presented in the conclusions part.
PL
Amoniak (NH3) to gaz powszechnie stosowany w różnych sektorach przemysłu, jest toksyczny i żrący, a powyżej określonego poziomu stężeń może zagrozić ludzkiemu zdrowiu i środowisku, dlatego ciągle trwają poszukiwania czułych, selektywnych i niezawodnych metod wykrywania gazów amoniakalnych. W niniejszym artykule dokonano przeglądu specyfikacji i podstawowych zasad działania czujników stosowanych w technikach wykrywania takich analitów. Szczegółowo przeanalizowano też mechanizm wykrywania i niedawny postęp w opracowywaniu zaawansowanych czujników do wykrywania gazu NH3 , opartych na nanorurkach węglowych (CNTs), a także ich modyfikacje obejmujące hybrydyzację z polimerami przewodzącymi. Przedstawiono również perspektywy rozwoju wysoko wydajnych czujników NH3.
PL
Na podstawie wyników przeprowadzonych badań można stwierdzić, że elektroniczne nosy mogą być narzędziem użytecznym do klasyfikacji wyrobów tytoniowych.
4
Content available Printed Textiles with Chemical Sensor Properties
EN
In this study the authors proposed the introduction of chemical sensors directly on textile surfaces in the form of conductive transmission parts using the screen-printing technique. A liquid vapour-sensitive, printing surface made with the use of multi-walled carbon nanotubes was also evaluated. Carbon nanotubes show effective chemo-sensory properties because the chemical agent leads to changes in electrical conductivity. The research concerned the assessment of sensor efficiency for chemical incentives in the form of selected fluids and their vapours. The best sensory properties were observed for polar vapour at a level of relative resistance over 40%. In the case of vapours of non-polar fluids the sensory reaction of the printed fabrics is much weaker – at a level of relative resistance of about 25%. The printed textile backings subjected to the influence of a fluid show an immediate reaction, while in the case of fluid vapour the reaction occurs after a few seconds. Detection of the presence of dangerous chemical agents such as organic liquids and their vapour is possible by means of a structure composed of sensors.
PL
Autorzy proponują wprowadzenie czujników chemicznych (chemical sensor) bezpośrednio na powierzchni wyrobów tekstylnych w postaci ścieżek elektroprzewodzących techniką sitodruku. Oceniano czułość zadrukowanych podłoży tekstylnych kompozycją atramentową na bazie nanorurek węglowych na bodziec chemiczny w postaci cieczy i ich par. Nanorurki węglowe wykazują właściwości chemo – sensoryczne, ponieważ czynnik chemiczny powoduje zmiany ich rezystancji elektrycznej. Badania skuteczności działania czujników dla bodźce chemiczne prowadzone były dla wybranych cieczy oraz ich par. Najlepsze własności sensoryczne uzyskano dla par cieczy polarny - na poziomie Rrel ponad 40%. W przypadku oparów cieczy niepolarnych czułość sensoryczna zadrukowanych tkanin była znacznie słabsza - na poziomie Rrel około 25%.Zadrukowane podłoża tekstylne, wykazują natychmiastową reakcję na bodziec chemiczny w postaci cieczy, zaś w przypadku oparów cieczy, reakcja następuje po upływie kilku sekund. Wykrywanie obecności niebezpiecznych środków chemicznych, takich jak ciecze organiczne oraz ich pary jest możliwe dzięki prawidłowej konstrukcji wytworzonych czujników.
5
PL
W artykule przedstawiono opis budowy oraz badania modułu czujników wielu gazów substancji chemicznych. Moduł jest w stanie wykrywać 11 różnych substancji w stanie gazowym jednocześnie i liczba ta może zostać zwiększona w miarę potrzeb. Moduł został zaprojektowany i zbudowany jako urządzenie do zainstalowania na mobilnych platformach bezzałogowych w zastosowaniach antykryzysowych.
EN
The paper describes the construction and the results of investigations of the multigas module of chemical contaminants sensors. The module is able to detect 11 different volatile chemical agents simultaneously and this number can be increased if needed. The module was designed and built as a device installed on mobile unmanned platform for anti-crisis application.
PL
Celem badań było określenie wpływu kompozytowej warstwy przyelektrodowej na podstawowe parametry grubowarstwowych rezystancyjnych czujników gazów. Warstwę kompozytową wykonano mieszając proszek SnO₂ ze związkiem metaloorganicznym złota. Zawartość złota w warstwie kompozytowej wynosiła 6,5% wag. po wypaleniu. Czujniki z kompozytową warstwą przyelektrodową charakteryzowały się wyższą czułością i selektywnością na amoniak.
EN
The purpose of study was to determine the influence of the composite by - electrode layer on the basic parameters of thick film resistive gas sensors. The composite layer was made by mixing SnO₂ powder with an organometallic gold compound. The concentration of gold in the composite layer was 6.5 wt% after burning. The sensors with the composite by-electrode layer showed a higher sensitivity and selectivity for ammonia.
7
Content available remote Influence of temperature on performance of chemical sensors
EN
The paper presents the temperature characteristics of three types of chemical sensors: ion-selective electrode, ion-sensitive field effect transistor, and optical sensor. Various pH sensors were tested in pH buffers within the temperature range 5-35°C. The measuring set-up consisted of a thermoregulator, a signal-conditioning unit designed to match the specific requirements of the sensor, a data acquisition card, and a personal computer. The system was controlled by a special application software developed under the LabView environment.
PL
Artykuł prezentuje zależności temperaturowe czujników chemicznych: elektrody jonoselektywnej, jonoczułego tranzystora polowego oraz czujnika optycznego. Badano czujniki pH w zakresie temperatur 5-35°C wykorzystując odpowiednie roztwory buforowe. W skład systemu pomiarowego wchodziły: termoregulator, układ dopasowujący sygnały pochodzące z czujników, karta pomiarowa oraz komputer osobisty. Pracę systemu nadzorowała aplikacja wykonana w środowisku LabYiew.
PL
Sitodruk, znany już w starożytności może okazać się użyteczną, nowoczesną technologią wytwarzania czujników chemicznych.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.