Ograniczanie wyników
Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Powiadomienia systemowe
  • Sesja wygasła!

Znaleziono wyników: 2

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  czułość detekcji
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
In analytical methods based on external standards, different averaging and interpolation methods yield different precision and accuracy. Gas chromatography measurements of freon F-l 1 in air were used to illustrate the influence of different averaging and interpolation methods on the accuracy and precision of measurements. The following methods: the average values of the standard peak areas for 6, 12 and 24 measuring points, the Newton 2-point interpolation method, and the Lagrange 3-point and 5-point interpolation were used and compared. It is shown that for an instrument of good stability the Newton 2-point interpolation method is usually sufficient. For an instrument of poor stability the 5-point Lagrange interpolation method is shown to yield the best precision and accuracy.
PL
W metodach analitycznych opartych na standardzie zewnętrznym różne sposoby uśredniania i interpolacji wpływają na dokładność i precyzję. W pracy na przykładzie chromatograficznych ciągłych pomiarów stężenia freonu F-11 w powietrzu pokazano wpływ metod uśredniania i interpolacji na dokładność i precyzję pomiarów. Porównano metodę uśrednionych wartości powierzchni pików standardu z 6, 12, 24 punktów pomiarowych oraz metody interpolacji: 2-punktową Newtona, 3-punktową i 5-punktową Lagrange'a. Pokazano, że dla stabilnej pracy aparatury pomiarowej 2-puktowa metoda interpolacji Newtona jest wystarczająca. Dla mniej stabilnej pracy aparatury metoda 5-puktowej interpolacji Lagrange'a pozwala uzyskać lepszą dokładność i precyzję pomiarów.
EN
During long term measurements of trace concentrations of CFCs in air by means of GC (Fisons, type 8000) equipped with two BCD detectors, working in a constant current mode, considerable changes in the detection sensitivity were observed. The increase in frequency/, causes the increase in the detection sensitivity. This observation is in contradiction to common opinion taking as a rule that the changes of the/ frequency are connected with the carrier gas contamination. The mathematical analysis, presented in this work, and based on the simplified model of the BCD, allows for an explanation of the influence of various physical parameters of the analytical system on the detection sensitivity. The difference in the/, value observed for two ECDs supplied with the same carrier gas can be explained by the individual characteristics of these detectors. The changes in the detection sensitivity of the analytical system, observed in the long term measurements, do not influence the detection level, since the ratio of the detector response to noise amplitude is constant.
PL
Podczas długo czasowych pomiarów śladowych stężeń związków chlorowcowych w powietrzu chromatografem gazowym Firmy Fisons wyposażonym w dwa detektory wychwytu elektronów pracujące w systemie stałego prądu jonizacyjnego, obserwowano znaczne zmiany czułości detekcji jednego z detektorów. Stwierdzono, że wzrost częstotliwości fa powoduje wzrost czułości detekcji, wzrost sygnału, co wydawało się sprzeczne z dotychczasową wiedzą, ponieważ uważa się, że wartość/, jest tym większa im gaz nośny jest bardziej zanieczyszczony. Przedstawiona analiza matematyczna przeprowadzona w oparciu o uproszczony model detektora wychwytu elektronów opisany w pracy [6] pozwoliła na określenie związków jakie wiążą czułość detekcji (S) z częstotliwościąfo, i innymi parametrami ukłdu pomiarowego. Różnica w wartościach fo, jaka występuje w dwóch detektorach wychwytu elektronów zasilanych tym samym gazem nośnym może być wyjaśniona indywidualnymi cechami detektorów. Stwierdzono, że zmiana wartości fo, nie wpływa na poziom detekcji ponieważ stosunek sygnału do amplitudy szumów pozostaje stały.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.