Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 6

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  cross-flow heat exchanger
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
1
Content available Utilization of Process Wastewater Heat
EN
This papers presents the results of computation of two heat exchangers used for heat utilization of industrial wastewater generated in a refined fiberboard production plant. The basic task was to cool wastewater to a temperature of approximately 40ºC enabling efficient centrifugation of suspended matter at the stage of wastewater pretreatment. A shell-and-tube heat exchanger with the power of 473 kW for water heating was developed for heating the production hall. A cross-flow exchanger was also developed for heating ventilation air in the boiler room building, power of which is 1703 kW. Thermal and hydraulic computation was performed, the required heat exchange surface was selected, the main structural characteristics of both exchangers were determined.
PL
W niniejszym artykule przedstawiono wyniki obliczeń dwóch wymienników ciepła typu służących do utylizacji ciepła ścieków przemysłowych powstających w zakładzie do produkcji uszlachetnionych płyt pilśniowych. Zadaniem podstawowym było schładzanie ścieków do temperatury ok. 40ºC umożliwiającej sprawne odwirowanie zawieszonych substancji na etapie wstępnego podczyszczania ścieków. Opracowano wymiennik płaszczowo-rurowy podgrzewający wodę na cele ogrzewania hali produkcyjnej o mocy 473 kW. Opracowano również wymiennik krzyżowy na cele podgrzania powietrza wentylacyjnego w budynku kotłowni, którego moc wynosi 1703 kW. Wykonano obliczenia cieplne i hydrauliczne, dobrano wymaganą powierzchnię wymiany ciepła, określono główne charakterystyki konstrukcyjne obu wymienników.
PL
Poprawne działanie instalacji wentylacji i klimatyzacji zależy od wielu czynników. Na początkowym etapie ważne jest odpowiednie zaprojektowanie i zwymiarowanie poszczególnych elementów wyposażenia instalacji, a następnie poprawne jej wykonanie. Wielu użytkowników instalacji wentylacji i klimatyzacji zaniedbuje jednak kolejny istotny element, którym jest odpowiednie serwisowanie i czyszczenie instalacji. W artykule porównano efektywność odzysku ciepła centrali wentylacyjnej wyposażonej w wymiennik krzyżowy dla dwóch stanów jego czystości. Badania przeprowadzono na stanowisku znajdującym się w Laboratorium Wentylacji i Klimatyzacji Przemysłowej na Wydziale Górnictwa i Geoinżynierii AGH w Krakowie. W wyniku przeprowadzonych badań określono wzrost efektywności odzysku ciepła dla badanego wymiennika krzyżowego po jego czyszczeniu.
EN
Proper ventilation and air conditioning systems working depends on many factors. At the beginning it is very important to perform design each elements of the system. Next important step is construction of the installation. Many users neglect another important element, which is proper servicing and cleaning of the elements of the installation. In the article are presented heat recovery efficiency measurements conducted for air handling unit with cross-flow heat exchanger. Two different cleanliness are considered. Everything were made on research station in Laboratory of Ventilation and Air-Conditioning in Faculty of Mining and Geoengineering at AGH University in Krakow. At the beginning were conducted measurements for dirty cross-flow heat-exchanger. Next the heat exchanger were cleaned, and the same measurements were conducted. According to the achieved results the increase of heat recovery efficiency after heat exchanger cleaning were described.
EN
In order to reduce ventilation heat loss and improve energy efficiency of low-energy buildings air-handling units (AHUs) with heat recovery are used. The article presents results of surveys performed in a passive building located in Katowice concerning the temperature efficiency of heat and cold recovery of two selected AHUs, with different heat exchangers. For this purpose the measurement data from the Building Management System (BMS) for the period 1.08.2015-31.07.2016 were used. The first unit was equipped with a rotary heat exchanger. Its average annual temperature efficiency of heat recovery was 47.2% annually. The efficiency of cold recovery amounted 52.9% on average for the warm half year. The second unit had a cross-flow exchanger. The average annual temperature efficiency of heat recovery in this device was 80.1%. The efficiency of cold recovery amounted 57.2% on average for the warm half year. Additional remarks concerning the temperature measurement in analysed units were also given.
EN
Distributions of media streams flowing in a cross-flow tube and fin heat exchanger are usually non-uniform. This could be an effect of the heat exchanger construction, its installation method, design of a flowing channel or all those factors combined. The problem of the non-uniform media flow in heat exchangers of different types is not new, and it has been investigated by many researchers. Early results were sometimes ambiguous. More recent outcomes indicate that the effect of the non-uniform inflow of heat carriers to the heat exchanger could be significant it may adversely affect the device’s efficiency to a large extent. Investigations of tube and fin cross-flow heat exchangers carried out for almost twenty years at the Institute of Thermal Technology of the Silesian University of Technology, by way of experiments and numerical simulations, also confirm these latest conclusions. The reduction in overall heat exchanger capacity, comparing to the uniform inflow of media, may reach up to 18%. This work presents results of experimental and computational investigations of tube, fin, cross-flow, double row heat exchangers air-water. The heat exchangers under consideration are built in the form of two rows of elliptic tubes with rectangular fins. The ribbing structure of the first heat exchanger is uniform. This device was investigated primarily in order to determine its efficiency but also the range and the form of non-uniform inflow of air. The air flow distribution was tested on a special test station during a series of measurements. The results of the analysis of this heat exchanger were used to design a second heat exchanger with a non-uniform structure of fins on individual tubes. It was assumed that by changing the heat transfer surface (thickening the fins) in the region of high air speed, the efficiency of modified heat exchangers could be enhanced. Testing this hypothesis is the main aim of this work. The experimental results generally confirm the hypothesis, showing a rise in efficiency of up to 8%. However, it should be noted that the design of the modified ribbing structure is not optimal and changing this structure impacts the hydraulic resistance and distribution of air mass flow rate at the heat exchanger inflow. This effect should be considered when evaluating the results.
PL
Celem publikacji jest opracowanie metody projektowania parametrów powietrza w systemie klimatyzacji z wykorzystaniem pompy ciepła do osuszania powietrza obiegowego i wymiennika krzyżowego.
EN
The aim of the publication is to show method of designing the air parameters in air conditioning system for swimming foods using heat pump for drying recirculated air and cross–flow heat exchanger. This article show also an example calculation.
EN
The paper deals with numerical thermodynamic analyses of cross-flow finned tube heat exchangers of the gas-liquid type. The authors postulate that some improvement of the heat exchanger performance may be achieved by applying a special ribbing structure - fitted to certain media flow conditions. First, the measurements have been carried out in order to determine the air inflow non-uniformity and next an own computer code HEWES has been used for numerical simulations in order to evaluate the impact of the measured non-uniformity on the exchangers' efficiency for the heat exchangers with unified ribbing structure. The numerical simulations have been repeated for heat exchangers with special ribbing structures - determined on the basis of experimental results. Results confirm the hypothesis - some increase in the total heat flow rate may be observed for the considered heat exchanger.
PL
Praca dotyczy termodynamicznej analizy krzyżowoprądowego, ożebrowanego wymiennika ciepła typu gaz-ciecz. Autorzy weryfikowali hipotezę zakładającą możliwość uzyskania poprawy efektywności działania urządzenia w wyniku zastosowania specjalnej, dostosowanej do warunków przepływu czynników, struktury ożebrowania. W pierwszej kolejności wykonane zostały pomiary określające zakres i postać niejednorodnego dopływu powietrza do analizowanego wymiennika ciepła, a następnie wykorzystano własny kod komputerowy HEWES do oceny wpływu tej niejednorodności na wydajność cieplną wymiennika. Obliczenia te dotyczyły wymiennika ciepła z jednorodnym ożebrowaniem. Symulacje numeryczne zostały następnie powtórzone dla przypadku wymiennika ze specjalną strukturą ożebrowania, która została dobrana dla wyznaczonych eksperymentalnie warunków dopływu powietrza. Uzyskane rezultaty potwierdzają postawioną na wstępie hipotezę - widoczny jest pewien wzrost wartości strumienia ciepła przekazywanego w wymienniku.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.