Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 3

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  cracked concrete
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
PL
W artykule przedstawiono rodzaje kotew metalowych stosowanych do betonu i sposoby przekazywania obciążenia z ich korpusu na podłoże. Omówiono różnice i ograniczenia wynikające z budowy poszczególnych kotew. Przedstawiono modele zniszczenia i zachowanie się kotew na skutek ich wyciągania bądź ścinania. Poruszono także niezwykle ważny aspekt instalacji kotew w podłożu zarysowanym.
EN
The paper presents the types of metal fasteners used in concrete and the ways of transferring the load from their body to the concrete. Differences and limitations resulting from the construction of particular fasteners are discussed. Models of failure and behaviour of the fasteners due to tension or shear are presented. An extremely important aspect of anchor installation in cracked concrete is also discussed.
EN
Aggregate interlock is a stress transfer mechanism in cracked concrete. After concrete cracks under tensile loading, crack interfaces can experience significant slip deformation due to the applied crack kinematics. Upon rising slip along crack interfaces, aggregate interlock stresses are generated which transfer shear stress and normal stress. Many experimental programmes and analytical expressions have been developed for several decades. However, a finite element model considering realistic crack surfaces was still not developed. The complexity of developing a FE model lies due to the mesoscopic nature of the problem. In this study, concrete mesoscale models were employed to generate realistic cracked concrete surfaces. Uniaxial tensile fracture propagation in concrete mesoscale models were achieved using Zero-thickness cohesive elements approach. Once cracked concrete FE models are developed, validation of the proposed FE models was conducted against two experimental campaigns. The study comprises the evaluation of the surface roughness index of the cracked concrete surfaces. The FE model predicts secondary cracking under low initial crack widths and mixed mode angles. FE predictions were further compared with Walraven’s simplified formulae, Bažant’s rough crack model, Cavagnis’s aggregate interlock formulae and contact density model and consistence agreement was observed. Finally, strengths and weaknesses of the proposed FE modelling approach for aggregate interlock was discussed and further implementations were also highlighted.
3
EN
This paper presents the results of an extensive electrochemical research work that was aimed at reproducing as close as possible the corrosive processes that take place along the rebar which reinforces concrete elements as being treated by mechanical loads and aggressive chloride ions. The tests have been carried out both on cuboidal blocks, reinforced by a plain rebar and on identical blocks reinforced by a ribbed bar. Prior to the measurements each sample had been subjected to a cyclic action of the aggressive environment by being exposed through 3.5 hour's time to the 3.1% strong solution of sodium chloride, and then to a drying process through 68.5 hour's time at the ambient temperature. The electrochemical tests embraced the measuring of the distribution of stationary potential, and that of the electrochemical polarization using the method adapted to the conditions inside the concrete elements. They made it possible to specify among other things the density of corrosion current and the resistance of polarization, which are used for measuring the corrosion process rate. We did find out that portions with a decreased potential did appear around each crack of the covering concrete. The strongest stimulation of electrochemical processes occurred in the presence of several cracks. Values of the corrosive potential, corrosion current density and polarization resistance did not depend on a width of the cracks. Actual values of the corrosion current density were lower in the samples reinforced with ribbed rebars than in the samples reinforced with plain rebars. This result evidences better protective properties of a concrete covering if a ribbed reinforcement is used.
PL
Przedstawiono wyniki badań elektrochemicznych, których celem było odwzorowanie procesów korozyjnych zachodzących wzdłuż pręta zbrojącego elementy betonowe poddane obciążeniom mechanicznym i agresywnemu działaniu jonów chlorkowych. Badania przeprowadzono na elementach prostopadłościennych zbrojonych pojedynczym prętem gładkim oraz identycznych elementach zbrojonych prętem żebrowanym. Przez kilkunastomiesięczny okres badań elementy próbne były obciążone stałymi siłami skupionymi w wykonanych indywidualnie urządzeniach cięgnowo-belkowych. W elementach próbnych generowano jedną rysę lub grupę trzech, czterech rys. Przed pomiarami elektrochemicznymi każdy element był poddawany cyklicznemu działaniu środowiska agresywnego przez 3,5 godziny ekspozycji w 3,1% roztworze chlorku sodowego, a następnie przez 68,5 godziny suszeniu w temperaturze otoczenia. Badania obejmowały pomiary rozkładu potencjału stacjonarnego oraz pomiary polaryzacyjne adaptowane do warunków występujących w elementach z betonu. Rozkład potencjału określono pH-metrem cyfrowym oraz elektrodą kalomelową. Badania polaryzacyjne wykonano metodą potencjodynamiczną, w układzie trójelektrodowym, stosując automatyczny zestaw do pomiarów elektrochemicznych. Zbrojenie elementu było elektrodą badaną, umieszczone w elemencie druty palladowe stanowiły elektrodę pomocniczą, natomiast jako elektrodę odniesienia przyjęto elektrodę kalomelową, przykładaną do powierzchni betonu nad osią zbrojenia. Określono m. in. gęstość prądu korozyjnego oraz opór polaryzacji, stanowiące miarę szybkości procesu korozyjnego. Stwierdzono, że odcinki obniżonego potencjału tworzyły się wokół każdej rysy w otulinie. Największe pobudzenie procesów elektrochemicznych następowało w obecności kilku rys. Wartości potencjału korozyjnego, gęstości prądu korozyjnego i oporu polaryzacji nie zależały od szerokości rys. W elementach zbrojonych prętami żebrowanymi rzeczywista gęstość prądu korozyjnego miała wartości mniejsze niż w elementach zbrojonych prętami gładkimi. Wynik ten świadczy o lepszych właściwościach ochronnych otuliny w wypadku zastosowania zbrojenia żebrowanego.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.