EN
The primary objective of the experiment was to determine the average coverage of the sprayed liquid on the plant surface according to the adopted coefficient of the spray surface of plants (Wpo). Examinations were performed under laboratory conditions, using a sprayer, which was moving with a constant operating speed, at various operating pressures. During the study four types of nozzles were used: standard and ejector. They sprayed objects, which were artificial plants, equipped with probes in the form of water-sensitive papers. Probes were placed on the horizontal and vertical surfaces of the plants. The degree of coverage was determined by computer image analysis. The analysis of obtained results showed that the coefficient of the surface spray has a significant impact on the size of the average surface coverage of sprayed objects. It was found that in case where the Wpo <1, standard nozzles are better for spraying, and when Wpo > 1, ejector nozzles and standard double may be used more successfully.
PL
Celem eksperymentu było określenie średniego pokrycia opryskiwanej powierzchni rośliny, w zależności od przyjętego współczynnika powierzchni opryskowych (Wpo). Badania wykonano w warunkach laboratoryjnych, przy użyciu opryskiwacza, który poruszał się ze stałą prędkością roboczą, ale przy różnych ciśnieniach pracy. Do badań użyto czterech typów rozpylaczy (standardowych i eżektorowych). Opryskiwanymi obiektami były sztuczne rośliny zaopatrzone w próbniki w postaci papierków wodoczułych, które umieszczano na powierzchniach poziomych i pionowych. Stopień pokrycia określono metodą komputerowej analizy obrazu. Analiza uzyskanych wyników badań wykazała, że współczynnik powierzchni opryskowych, ma znaczący wpływ na wielkość średniego pokrycia powierzchni opryskiwanych obiektów. Stwierdzono również, iż w przypadku, kiedy Wpo<1 korzystniej jest do oprysku używać rozpylaczy standardowych, a kiedy Wpo>1, z większym powodzeniem można stosować rozpylacze eżektorowe oraz standardowe dwustrumieniowe.
PL
W artykule przedstawiono wyniki analizy porównawczej działania dwóch rozpylaczy na podstawie analizy stopnia pokrycia opryskiwanych obiektów. Do badań wybrano dwa rozpylacze dwustrumieniowe różniące się ustawieniem rozpylonych strug. Były to rozpylacze IDKT firmy Lechler i HiSpeed firmy Agrotop. Podczas badań rozpylacz IDKT odchylono od pionu tak, by uzyskać identyczne ustawienie rozpylonych strug jak w przypadku rozpylacza HiSpeed. Celem badań było porównanie stopnia pokrycia opryskiwanych obiektów przy takim samym ustawieniu rozpylonych strug obu rozpylaczy. Analiza porównawcza uzyskanych wyników obu wybranych do badań rozpylaczy nie wykazała dużego zróżnicowania stopnia pokrycia opryskiwanych obiektów.
EN
The study presents results of the comparative analysis of two sprayers acting on the basis of the coverage degree of sprayed objects. Two double-stream sprayers differing in sprayed streams setting were selected to research. It was the sprayer IDKT of company Lechler and HiSpeed of company Agrotop. During the tests the sprayer IDKT was deflected from vertical so as to obtain the same setting of spray streams as in the case of sprayer HiSpeed. The aim of this study was to compare the degree of coverage of objects sprayed at the same setting of sprayed streams of both sprayers. Comparative analysis of the results of two sprayers selected for studies did not show a large diversity of sprayed objects coverage.
PL
W opracowaniu przedstawiono wyniki badań porównawczych stopnia pokrycia opryskiwanych obiektów przy użyciu rozpylaczy eżektorowych: jednostrumieniowego (AVI 11002) i dwustrumieniowego (AVI TWIN 11002). Pomiary przeprowadzono przy dwóch prędkościach roboczych agregatu, trzech ustawieniach rozpylaczy i stałej dawce cieczy. Badania wykonano w warunkach laboratoryjnych. Użyto nośnika rozpylaczy, symulującego pracę opryskiwacza polowego. W doświadczeniu zastosowano papierki wodnoczułe, zamocowane na trzech sztucznych roślinach, rozstawionych w 3-metrowych odstępach. Próbniki założone na sztuczne rośliny tworzyły obiekty oznaczone jako: poziomy górny (Apog ), poziomy dolny (Apod ), pionowy najazdowy (Anj ) oraz pionowy odjazdowy (Aoj ). Po wykonaniu pomiaru papierki poddano komputerowej analizie obrazu w celu określenia stopnia pokrycia, wartości przedstawiono na wykresach słupkowych. Wyniki poddano wieloczynnikowej analizie wariancji, która wykazała, że zastosowany rozpylacz i prędkość agregatu istotnie wpłynęły na stopień pokrycia obiektów poziomych górnych, nie stwierdzono natomiast, w tym przypadku, istotnego wpływu kąta ustawienia rozpylaczy. Wszystkie przyjęte do badań parametry pracy rozpylaczy istotnie wpłynęły na pokrycie obiektów pionowych. Wyższe wartości stopnia pokrycia obiektów pionowych zaobserwowano dla rozpylacza dwustrumieniowego, natomiast w przypadku obiektu poziomego górnego dla rozpylacza jednostrumieniowego. Na obiektach oznaczonych jako poziome dolne nie odnotowano zauważalnego pokrycia opryskiwaną cieczą.
EN
The research paper includes results of comparative research of the coverage degree of the sprayed objects with the use of air induction sprayers: a one-stream (AVI 11002) and two-stream (AVI TWIN 11002). The measurements were carried out at two work speeds of an aggregate, three settings of sprayers and a fixed dose of liquids. The research was conducted in laboratory conditions. A sprayer carrier was applied, which stimulates operation of a field sprayer. Water-sensitive papers were used in an experiment. They were mounted to three artificial plants spaced in 3-metres intervals. Samplers placed on artificial plants formed surfaces determined as: an upper level (Apog), a lower level (Apod), vertical approach (Anj) and vertical leaving (Aoj). Upon carrying out the measurement, the papers were subjected to a computer image analysis in order to determine the coverage degree, the values have been presented at bar charts. The results were subjected to a multi-factor analysis of variance, which proved that the sprayer used and the speed of aggregate significantly influence the coverage degree of upper horizontal objects, whereas, no significant influence of the angle of sprayers setting has been determined in this case. All working parameters of sprayers, which were accepted for the research, have significantly influenced coverage of vertical facilities. Higher values of coverage degree of vertical facilities were reported for a two-stream sprayer, while in case of an upper horizontal sprayer for a one-stream sprayer. No noticeable coverage with a sprayed liquid has been noticed on horizontal objects.
PL
W pracy przedstawiono wyniki badań stopnia pokrycia opryskiwanych obiektów z zastosowaniem rozpylacza dwustrumieniowego eżektorowego w zmiennych warunkach i parametrach rozpylania. Badania przeprowadzono w warunkach laboratoryjnych. Obiektami opryskiwanymi były sztuczne rośliny z zamontowanymi na nich papierkami wodoczułymi (PSP). W wyniku przeprowadzonej komputerowej analizy obrazu opryskanych powierzchni stwierdzono istotny wpływ przyjętych parametrów rozpylania na stopień pokrycia przy opryskiwaniu powierzchni pionowej najazdowej i poziomej górnej. Nie stwierdzono natomiast pokrycia powierzchni poziomych spodnich na poziomie statystycznie istotnym.
EN
The work presents results of the research on coverage degree for objects sprayed using a double stream ejector type atomiser at changeable spraying conditions and parameters. The tests were performed in laboratory conditions. Sprayed objects included artificial plants with water sensitive papers (PSP) attached to them. Completed computer image analysis of sprayed surfaces allowed to observe significant impact of the assumed spraying parameters on coverage degree while spraying vertical approach surface and upper horizontal surface. Whereas, the researchers observed no coverage of bottom horizontal surfaces at statistically significant level.
PL
Celem badań było określenie zależności stopnia pokrycia rozpyloną cieczą opryskiwanych powierzchni od parametrów pracy eżektorowego rozpylacza dwustrumieniowego przystosowanego do wykonywania zabiegów z większymi prędkościami roboczymi Badania przeprowadzono w warunkach laboratoryjnych. Analiza wariancji uzyskanych wyników wykazała istotny wpływ przyjętych parametrów na stopień pokrycia opryskiwanych obiektów z wyjątkiem wpływu zmiany ustawienia na pokrycie obiektów poziomych.
EN
The purpose of the research was to determine dependence of coverage degree of sprayed surfaces with sprayed liquid from an ejector double-stream sprayer adjusted to performance with higher working speeds. The studies were carried out in laboratory conditions. Variation analysis of the obtained results proved considerable influence of the accepted parameters on the coverage degree of the sprayed surfaces except the influence of position change for spraying horizontal surfaces.
PL
Badania zostały przeprowadzone w warunkach laboratoryjnych na specjalnie do tego celu skonstruowanym stanowisku badawczym. Celem badań było określenie wpływu ustawienia wybranych rozpylaczy w płaszczyźnie równoległej do kierunku jazdy i prostopadłej do podłoża oraz przyjętych parametrów rozpylania na stopień pokrycia opryskiwanych powierzchni w warunkach działania czołowego strumienia powietrza wynikającego z ruch opryskiwacza. Analiza wyników badań wykazała istotny wpływ przyjętych parametrów pracy i ustawienia rozpylaczy na stopień pokrycia opryskiwanych powierzchni a zwłaszcza wpływ odchylania rozpylonej strugi w kierunku przeciwnym do działania strumienia powietrza na pokrycie opryskiwanych powierzchni pionowych.
EN
The tests were carried out in laboratory conditions at a stand specially designed for that purpose. The purpose of the research was to determine relationship between the impact of positions of selected sprayers in plane parallel to run direction and perpendicular to the ground, and assumed spraying parameters on coverage degree for surfaces sprayed under the influence of air stream generated as a result of spraying machine run. Analysis of test results has proven significant effect of the assumed work parameters and sprayer positions on coverage degree for sprayed surfaces, and in particular the effect of sprayed stream deflection in direction opposite to air stream action on coverage of sprayed vertical surfaces.