The development of tourism in valuable natural areas is becoming increasingly dynamic, and therefore this phenomenon requires a more thorough investigation. An increased tourist traffic in a national park entails a range of consequences, which are not irrelevant for the protected nature. The aim of the study is a spatial and quantitative description of tourist traffic in the Stołowe Mountains National Park, basing on the data received from pyro-electric counters in Monitoring System of tourist traffic. The system was created through to cooperation between national park staff and Department of Tourism and Recreation Adam Mickiewicz University in Poznan (Rogowski, Małek, 2016). In the period from 16th September 2016 to 31th August 2017 were 858 346 entries to national park. July and August were the most popular months which accounts for 22% of the total number of entries. All data was presented the visitors flow indicating the most popular areas and regions and the trails sections.
2
Content available Model symulacyjny gęstościomierza radiometrycznego
PL
Gęstościomierze radiometryczne znajdują zastosowanie w układach monitoringu i sterowania różnych procesów technologicznych, w tym również procesów przeróbki węgla kamiennego takich jak: wzbogacanie w cieczy ciężkiej, wzbogacanie w osadzarce, flotacja węgla. Gęstościomierze te działają na zasadzie absorpcji promieniowania gamma. Głowica pomiarowa gęstościomierza składa się ze źródła promieniowania oraz detektora, zwykle w postaci licznika scyntylacyjnego. Sygnał z detektora promieniowania jest ciągiem impulsów, który jest sygnałem stochastycznym o rozkładzie czasowym Poissona. Impulsy te zliczane są często za pomocą licznika impulsów, stanowiącego rodzaj filtru dolnoprzepustowego. Zależność pomiędzy mierzoną średnią wartością gęstości ośrodka, a średnią częstością zliczanych impulsów ma teoretycznie charakter wykładniczy. W artykule przedstawiono model symulacyjny gęstościomierza radiometrycznego. Opisano metodę pomiarową oraz podano równania modelu gęstościomierza. Przedstawiono również przykładowe wyniki badań symulacyjnych w formie graficznej.
EN
Radiometric density meters are widely used in the industry to monitor different technological processes also in coal preparation such as: Heavy-media separation, Jigging, Flotation. Operation of the radiometric density meters is based on the method of gamma radiation absorption. The measuring head of the radiometric density meter consists of a radiation source and a detector usually in the form of a scintillation counter. The output signal from the detector is sequence of pulses which is always a stochastic signal with Poisson distribution. These pulses are often counted by a counter being a kind of a low-pass digital filter. The relation between the measured medium density and the mean intensity of registered pulses is theoretically exponential. In the paper there has been presented a simulation model of the radiometric density meter. There have been described the measurement method and given densitometer model equations. Example simulation results have also been presented in a graphic form.
3
Content available remote Dowodzenie w działaniach przeciwrebelianckich
EN
Counter – rebels activities have complex and unconventional nature. Moreover need especially, comprehensive approach to the problem of command & control during accomplish the mission by task forces in clashes with rebels. Experiences gained by commanders and staffs are valuable field to consideration in those area of science penetration. However, there are a lot of doubts, which should be taken under consideration in aspect of C² in counter – rebel activities. An article will present author's conclusions connected with contemporary counter – rebel activities, their principles and forms, with strong focus on command and control during them. The second part of it will concern desired battlefield management systems in those type of tactical activities. Suggestion connected with this area of interest will finish the article.
PL
Złożoność działań przeciwrebelianckich wiąże się z koniecznością opracowania stosownych procedur oraz zaimplementowania systemów automatyzacji dowodzenia na poziomie taktycznym. Powyższa potrzeba wynika z doświadczeń kolejnych zmian biorących udział w operacjach poza granicami kraju. Artykuł zawiera wyniki badań autora na temat zasad i form prowadzenia działań przeciwrebelianckich, ze zwróceniem szczególnej uwagi na zagadnienia dowodzenia. Ponadto akcentuje potrzebę oraz wymagania stawiane systemom zarządzania polem walki w działaniach tego typu. Sugestie dotyczące powyższego obszaru zawarte zostały w końcowej części niniejszego artykułu
4
Content available remote Design of Digital Circuits with Current-mode Gates
EN
The paper deals with the problem of digital circuit design based on the current-mode gates - novel digital elements operating with a constant, continuous power supply current. The purpose is the provision of a high level noise immunity of chips which contain both analog and digital circuits. The logical properties and several identities of the current-mode logic and some expressions for a conversion of the Boolean functions into the current-mode functions are represented. Based on these properties and expressions, the approaches of minimizing the current logic functions are derived. Moreover, a new concept of the low-voltage current-mode gates realization and the two new types of the current-mode gates are designed for the next reduction of the current mode digital circuit complexity. Based on these approaches and new types of the gates, the functional schemes of some current-mode combinatorial and sequential circuits are derived. The obtained circuits are characterized by lower hardware overheads (up to 35%) in comparison with similar hardware based on the classical voltage type gates.