Protective coating of reinforcement extends the period of safe use of reinforced concrete structures. However, the available literature does not present any methods for reliable evaluation of extended durability of concrete members with galvanized reinforcement compared with conventional rebars without any protection. This paper proposes a simple method of comparative evaluation of durability on the basis of corrosion current density in the function of time measured with polarization (LPR and EIS) methods. After converting distribution of corrosion current density into distribution of corrosion rate CR indicator, accumulated corrosion loss of zinc coating on a rebar was determined by numerical integration of the surface under the distribution of the CR indicator in the function of time. Then, as further corrosion rate of zinc coating was predicted until dissolution of its thinnest fragment, the extended durability of reinforced concrete member was estimated. This extended time was a result of applying the protective coating of reinforcement in the form of hot-dip galvanisation.
PL
W wyniku zastosowania ochrony powłokowej zbrojenia w konstrukcjach żelbetowych istotnie wydłuża się okres ich bezpiecznego użytkowania. W literaturze przedmiotu nie wskazuje się jednak sposobów miarodajnej oceny wzrostu trwałości elementów betonowych z ocynkowanym zbrojeniem w porównaniu z tradycyjnie wykonywanymi elementami z prętami, w wypadku których nie zastosowano żadnej ochrony. W artykule zaproponowano prosty sposób porównawczej oceny trwałości na podstawie realizowanych w funkcji czasu pomiarów gęstości prądu korozyjnego metodami polaryzacyjnymi (LPR i EIS). Po przeliczeniu rozkładów gęstości prądu korozyjnego na rozkłady wartości wskaźnika szybkości korozji CR sumaryczny ubytek korozyjny powłoki cynkowej na pręcie zbrojeniowym wyznaczono przez numeryczne całkowanie powierzchni pod rozkładem wskaźnika CR w funkcji czasu. Następnie, prognozując dalszą szybkość korozji powłoki cynkowej do momentu roztworzenia jej najcieńszego fragmentu, oszacowano czas wydłużenia trwałości elementu żelbetowego dzięki zastosowaniu ochrony powłokowej zbrojenia w formie ogniowej powłoki cynkowej.
PL
W pracy przedstawiono wyniki polaryzacyjnych badań stałoprądowych wykonywanych na fragmentach prętów zbrojeniowych znajdujących się w wyciętych z konstrukcji żelbetowych rdzeniach. W pierwszym etapie badań zastosowano tradycyjny układ trzech elektrod, w którym elektrodą badaną był pręt zbrojeniowy w walcowym rdzeniu, elektrodą pomocniczą krążek blachy ze stali trudnordzewiejącej, a elektrodą odniesienia klasyczna Ag, AgCl | Clˉ w korpusie szklanym. Elektrody pomocnicza i odniesienia były przykładane do płaskiej powierzchni próbki przez wilgotną podkładkę filcową lub żel przewodzący. W drugim etapie badań zastosowano alternatywny układ elektrod, w którym elektrodą pomocniczą była powłoka lakieru z dodatkiem proszku srebra naniesiona na pobocznicę próbki, a pręt grafitowy osadzony w próbce wykorzystywano jako elektrodę odniesienia. Wyniki badań w warunkach powietrzno-suchych wykazały, że tradycyjne - elektrody przykładane do powierzchni betonu powodują duże zaburzenia wyników uniemożliwiające ich analizę, natomiast elektrody na stałe osadzone w betonie w tych samych warunkach wilgotnościowych pozwalają uzyskać zadawalające rezultaty.
EN
This article describes results from d.c. polarization measurements of rebar fragments in concrete cores drilled from a structure. In the first stage of tests, a traditional arrangement of three electrodes was applied, in which the working electrode was the rebar in a cylindrical core, the counter electrode was a stainless steel disk, and the reference electrode was a traditional Ag, AgCl | Clˉ electrode in a glass body. The counter and reference electrodes were applied to a flat surface of the specimen covered with a wet felt washer or conductive gel. In the second stage of tests, an alternative electrode setup was used, in which the reference electrode was covered with the varnish and silver powder additive present on the specimen side surface, and a graphite rod in the specimen was used as the reference electrode. Results from tests performed under dry air conditions indicated that traditional electrodes applied to concrete surface caused significant discrepancies in results, and consequently their analysis became impossible. And electrodes permanently embedded into concrete provided satisfactory results for tests under the same conditions.
EN
In this paper, the application of interval arithmetic in the affine formulation to the determination of time to initialization of corrosion cracking of reinforced concrete structures was formulated. The calculations ware made with the use of the incremental FEM formulation (backward Euler scheme) and the library of numerical procedures for the interval-affine computations INTALB.
PL
W artykule przedstawiono wyniki badań polaryzacyjnych metodami LPR i EIS wykonanych na próbkach żelbetowych, po dwukrotnym wywołaniu w okresie 3 lat, zaawansowanych procesów korozyjnych na zbrojeniu w betonie. W trakcie badań czynnikiem korozyjnym były chlorki, a przebieg degradacji w komorze klimatyczno-korozyjnej stymulowano otrzymując temperaturę w przedziale 7÷35°C i wilgotność powietrza w zakresie 40÷90%. Trzyletni monitoring rozwoju korozji zbrojenia w betonie pokazał, że wykonana po ponad dwuletniej przerwie ponowna inicjacja zaawansowanych procesów korozyjnych na stali w betonie nie spowodowała znacząco odmiennego rozkładu szybkości korozji, niż przy pierwszej inicjacji korozji. Ponadto długość okresu rozwoju korozji zbrojenia nie miała większego wpływu na uzyskane wyniki badań.
EN
This papers presents results from polarization tests using LPR and EIS techniques, conducted on reinforced concrete specimens after inducing twice advanced corrosion processes on the concrete reinforcement during last 3 years. During the tests, chlorides were corrosion inducing agents, and degradation in a climatic and corrosion chamber was stimulated by obtaining a temperature in a range of 7÷35°C and humidity in a range of 40÷90%. A 3-year monitoring of corrosion development of reinforcement in concrete indicated that inducing advanced corrosion on steel in concrete after more than two years did not result in a significantly different distribution of corrosion rates compared to corrosion induced for the first time. Moreover, the length of corrosion development in reinforcement had little impact on the obtained results.
PL
Przedstawiono badania mikroskopowe styku zbrojenia i betonu z uwzględnieniem procesu korozji wywołanej działaniem roztworu chlorku. Wykonano zdjęcia SEM-BSE oraz mikroanalizy EDS. Stwierdzono dyfuzję produktów korozji do strefy betonu grubości 0,4 mm, odspojenie się zgorzeliny od stali oraz gromadzenie produktów korozji także pod odspajającą się zgorzeliną.
EN
The paper presents microscopic examinations of reinforcement and concrete interface, taking into account corrosion process induced by chloride solution. BSE-SEM images and EDS microanalysis was performed. Diffusion of reinforcement corrosion products to the concrete zone of 0.4 mm thickness, detachment of the mill scale from the steel and the accumulation of steel corrosion products under the mill scale breaking away was stated.
6
Content available remote Elektrochemiczne badania korozji zbrojenia żelbetowych silosów na cement
PL
Użytkowana ponad 40 lat bateria dwunastu żelbetowych silosów na cement wykazywała szereg uszkodzeń płaszcza zewnętrznego pomimo bieżących napraw. W przeprowadzonych badaniach technicznych stwierdzono wiele nieprawidłowości wykonawczych oraz lokalną korozję prętów zbrojeniowych. W celu wykazania rzeczywistego stanu zbrojenia wykonano badania korozyjne na wyciętych z konstrukcji rdzeniach betonowych zawierających fragmenty stalowych prętów zbrojeniowych. Elementy próbne umieszczano w komorze korozyjnej w ściśle określonych warunkach termiczno-wilgotnościowych. Uzyskana w badaniach szybkość korozji była w mniejszym stopniu zależna od tych warunków, natomiast duży wpływ miała jakość betonu otulenia.
EN
A battery of twelve reinforced concrete silos for cement being used for over 40 years has shown a series of deteriorations in the external surface of the silo shell although running repairs were performed. The conducted technical tests showed many performance irregularities and the local corrosion of rebars. The corrosion tests aimed at demonstrating the existing conditions of the reinforcement, were performed on concrete cores cut out from the structures. The cores contained fragments of steel rebars. Test elements were placed in a corrosion chamber under precisely specified thermal and humidity conditions. The corrosion rate determined during the tests was less dependent on those conditions, however the quality of concrete cover had a great impact on that rate.
7
Content available remote Badania szybkości korozji zbrojenia żelbetowych zbiorników na wodę
PL
W użytkowanych ponad 20 lat żelbetowych zbiornikach wody pitnej powstały uszkodzenia wewnętrznych wypraw, co zaniepokoiło instytucje nadzoru budowlanego, ze względu na zagrożenie korozją zbrojenia i awarią konstrukcji. W celu wykazania rzeczywistego stanu zbrojenia podjęto badania korozyjne. Badania przeprowadzono na wyciętych z konstrukcji rdzeniach betonowych zawierających fragmenty prętów zbrojeniowych, które umieszczano w komorze korozyjnej w ściśle określonych warunkach termiczno-wilgotnościowych. W komorze modelowano przeciętne warunki występujące w zbiorniku napełnionym wodą oraz warunki sprzyjające rozwojowi procesu korozji. Wyniki badań wykazały brak przesłanek do bezzwłocznego wyłączenia z eksploatacji obiektu i umożliwiły dalsze użytkowanie z jednoczesnym przygotowaniem do generalnego remontu.
EN
Deterioration of internal linings in the reinforced concrete water tanks operated for over 20 years was observed which alarmed the construction supervisory authorities because of a potential risk of reinforcement corrosion and failure of the structure. Corrosion tests were undertaken to present the existing conditions of the reinforcement. The tests were performed on concrete cores cut out from the structures. The concrete cores which contained fragments of rebars, were placed in a corrosion chamber under precisely specified thermal and humidity conditions. The average conditions existing in a tank filled with water and the conditions favourable for the development of corrosion process were simulated in the chamber. The test results demonstrated lack of any reasons for immediate closing down the facility and thus, it could be further operated while simultaneous works preparing the facility for major repair were conducted.
EN
The article describes non-destructive electrochemical method that assesses the severity of corrosion of reinforcement in concrete and presents experimental studies carried out in application of this method. The study was conducted on two types of concrete specimens of differing type cement: CEM I and CEM IIIA. The specimens tests were subjected to cycles of freezing and thawing process in a solution of NaCl. Then on the specimens the measurements were carried out, which allowed for the observation of degradation and the development of concrete cover of reinforcing steel corrosion. The measurements were performed with using a test apparatus by which it was possible to determine the existence of corrosion and its severity using three independent parameters: fixed potential and its gradient, the resistivity of concrete cover and densities of the corrosion current. The results obtained enabled the analysis of corrosion occurring in the specimen of reinforced concrete as well as to assess the effectiveness of the apparatus used for the measurement.
9
Content available remote Podstawowe równania modelu degradacji otuliny w wyniku korozji zbrojenia
EN
This paper presents the sketch of the model that can be used for the analysis of concrete cover in the corrosion conditions. The application of this model requires formulation of FEM theory equations. The presented model in the sense of idea is complete and can be used for determination of exploitation time of the cover in the case as well of chloride and the other type of corrosion.
PL
Przedstawiono wyniki badań szybkości korozji zbrojenia w próbnych elementach betonowych w dwóch przypadkach: pasywacji prętów zbrojeniowych oraz korozji stali wywołanej karbonatyzacją otuliny betonowej. Badania przeprowadzono metodą potencjodynamiczną stosując przeciwelektrody o trzech różnych długościach. Wartości gęstości prądu korozyjnego uzyskane za pośrednictwem krótkich przeciwelektrod odniesiono do gęstości prądu wyznaczonego przy użyciu najdłuższej elektrody pomocniczej, o wymiarach zbliżonych do elektrody badanej (zbrojenia), zapewniającej polaryzowanie całego pręta. W ten sposób określono umowny zasięg polaryzowania podłużnych elektrod badanych, który pozwolił na oszacowanie rzeczywistej szybkości korozji zbrojenia w konstrukcjach żelbetowych.
EN
Potentiodynamic polarization tests in concrete structures for passivation and corrosion of steel caused by carbonatization of concrete The test results of reinforcement corrosion rate in concrete specimens have been presented for two cases: passivation of reinforcing bars and corrosion of steel which arose as a result of carbonatizaton of concrete cover. The tests were carried out by potentiodynamic method, using counter electrodes of three different lengths. The values of corrosion current density obtained by short counter electrodes were compared to corrosion current density determined via the longest counter electrode of dimension similar to working electrode (reinforcement), this counter electrode ensured polarization of the whole rod. In this way the assumed polarization range of the oblong working electrodes has been determined, which allowed to assess the real corrosion rate in concrete structures.
EN
The paper is concerned with detection of corrosion of steel reinforcement in reinforced concrete construction by method of measurement change of electric resistance. By change of electric resistance is possible to consequently determine corrosive decrease of inbuilt steel reinforcement. From monitored construction was removed a part of inserted reinforcement therefore, in order that the real corrosion decrease of cross-section of reinforcement could be determined on this reinforcement in laboratory conditions.
EN
The modelling of corrosion tests on steel rod reinforcement has been shown. Three cases have been carried out — passivation, general corrosion and local corrosion. The liquid acting on the reinforcement in pores of concrete is modelled by alkaline solution and water. The tests have been carried out by the polarization method using counter electrodes of three different lengths. Potential changes of the outer edges of rods have been described too. The real corrosion rate of steel has been determined in the measuring vessel. Experimentally determined distribution of potential changes has been confirmed by calculations. The potential changes are insufficient to determine the polarization range, which the real corrosion current density dependents on. On the basis of tests in the measuring vessel it has been confirmed that the values of corrosion current density in models of reinforcement which are polarized on all its length may be recognized as real. The assumed polarization range of the oblong working electrodes has been determined by comparing the corrosion current density obtained by short counter electrodes, with the current density calculated under uniform polarization conditions.
PL
Przedstawiono badania korozyjne stalowych prętów modelujących zbrojenie elementów żelbetowych w trzech charakterystycznych przypadkach — pasywacji, korozji ogólnej wywołanej utratą właściwości ochronnych otuliny oraz korozji lokalnej występującej w obrębie zarysowania betonu. Działającą na zbrojenie ciecz w porach betonu odwzorowano roztworem zasadowym i wodą. Stan pasywny i korozję ogólną modelowano na elektrodach prętowych ze stali zbrojeniowej w roztworze zasadowym i wodzie. Korozję lokalną odwzorowano w wodzie na podobnej elektrodzie prętowej, lecz wykonanej ze stali zbrojeniowej i stali nierdzewnej. Badania przeprowadzono metodą polaryzacji stosując przeciwelektrody o trzech różnych długościach. Oddzielnym układem elektrycznym wyznaczono także wywołane polaryzacją zmiany potencjału skrajnych części prętów. Rzeczywistą szybkość korozji stali zbrojeniowej i nierdzewnej w identycznych roztworach określono metodą polaryzacyjną w typowym naczyniu pomiarowym. Wyniki pomiarów zmian potencjału świadczyły o spolaryzowaniu całych elektrod podłużnych. Wyznaczone eksperymentalnie rozkłady zmian potencjału potwierdzono obliczeniami metodą analogii układów przewodzących. Jednak uzyskane w ten sposób wyniki nie były wystarczające do określenia zasięgu polaryzacji, od którego zależy rzeczywista wartość gęstości prądu korozyjnego. Natomiast gęstość prądu korozyjnego wyznaczona elektrodami pomocniczymi o zróżnicowanych długościach wskazała na znaczenie zasięgu polaryzacji. Na podstawie badań w naczyniu pomiarowym stwierdzono, że wartości gęstości prądu korozyjnego w modelach zbrojenia polaryzowanego na całej długości można uznać za rzeczywiste. W przypadku polaryzowania elektrod podłużnych przeciwelektrodami o mniejszej powierzchni (60% i 20% długości elektrody badanej) gęstości prądu korozyjnego były mniejsze (stan pasywny i korozja ogólna) lub prawie identyczne (korozja lokalna). Odnosząc gęstość prądu korozyjnego uzyskanego za pośrednictwem krótkich przeciwelektrod do gęstości tego prądu wyznaczonego w warunkach odpowiadających rzeczywistej szybkości korozji określono umowny zasięg polaryzowania podłużnych elektrod badanych.
EN
The carbonation of concrete and the corrosion of reinforcement are significant service life factors. The modelling of these phenomena via random fields and subsequent stochastic finite element analysis (SFEM) is suggested in this paper. The statistical variation of carbonation of concrete and the corrosion of reinforcement are taken into account. A constitutive model of deterioration based on the change of the structural stiffness is applied in order to make the model tractable for the use in subsequent structural analysis. For that reasion deterioration constitutive model is implemented into the stochastic finite element method. The two-dimensional plane elastic stress/strain stochastic isoparametric quadrilateral finite elements are used. A Monte Carlo type simulation of random fields is combined with Neumann expansion of the inverse global stiffness matrix. Numerical results are presented for a reinforced concrete beam under given environmental conditions. It is shown that the proposed method of analysis can be used to estimate the statistical variation of displacements and the stress of general deterioration - sensitive concrete structure. The proposed approach can contribute to the efficient prediction of random behaviour of RC structures under deterioration by carbonation of concrete and the corrosion of reiforcement.
PL
Karbonizacja betonu i korozja zbrojenia żelbetu sa istotnymi faktami wpływającymi na jego żywotność. W pracy zaproponowane zostało podejście do modelowania tych zjawisk z wykorzystaniem podporządkowanych elementów skończonych. Przy czym uwzględnia się statystyczne wariacje karbonizacji betonu i korozji zbrojenia. Konstytutywny model degradacji oparty jest na zmianie strukturalnej sztywności i zastosowany został do zbudowania modelu przydatnego do zastosowania podporządkowanej analizy strukturalnej. W ten sposób konstytutywny model degradacji realizowany jest stochastyczną metodą elementów skończonych, przy wykorzystaniu dwuwymiarowych płaskich, sprężyście odkształcalnych, izoparametrycznych elementów czworokątnych. Symulacja typu Monte Carlo przypadkowych pól jest połączona z ekstrapolacją Neumana odwróconej globalnej macierzy sztywności. Wyniki obliczeń numerycznych przedstawione są dla zbrojenia betonu przy zadanych warunkach zewnętrznych. Wykazano, że zaproponowana metoda może być wykorzystana do oceny statystycznej wariacji przemieszczeń i naprężeń degradującej struktury betonowej. Proponowane podejście może być również zastosowane do efektywnego prognozowania przypadkowego zachowania się żelbetu na skutek pogorszenia się właściwości betonu w efekcie karbonizacji i korozji zbrojenia.