Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Powiadomienia systemowe
  • Sesja wygasła!
  • Sesja wygasła!
  • Sesja wygasła!

Znaleziono wyników: 12

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  correction factor
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
Understanding the impact of power harmonic on energy transmission play an important role not only in the operation process but also in the designing procedure of MV grid. In 6kV mining grids of Vietnamese coal mines, because of rapidly utilizing the power electronic machines, the power quality violation occurs very frequently. This lead to many disadvantages such as: the increase of power losses, voltage distortion, over-heating in transformers and conductors. Moreover, the presence of power harmonic bring the bad impact of skin effect and proximity on conductor including overhead-conductors and cables. The actual operation exhibits that the losses of transmission lines are approximately over 50% of total network losses. If there are power quality violation, this amount could be higher. Basing on investigating the fact of power harmonic violations in 6kV grid of both underground and surface mines, the paper will analyze this kind of impact. An algorithm relying on Matlab programming is used to calculate the energy losses. Results are compared with on-site measurement datas and lab-measurement to obtain series of correction factors corresponding to individual line’s cross section. The outcomes of research could be applicable for power utilities to have better analysis in the designing stage of mining MV grids.
EN
The paper presents the issues concerning contact stresses and inter-tooth slip of a power shift gear used in the powertrain of a wheel loader. The kinematic diagrams on individual gear ratios of the transmission are presented. Using appropriate numerical values of contour shift coefficients (correction coefficients), normal bilateral gearing, pre-pitch unilateral gearing, and post-pitch unilateral gearing were considered. In each of the three types of gearing, contact stresses and inter-tooth slip were calculated for each gear pair and at each gear ratio level, using an author's computer program with multi-criteria optimization.
PL
W pracy przedstawiono zagadnienia dotyczące naprężeń kontaktowych i poślizgu międzyzębnego przekładni zębatej power shift stosowanej w układzie napędowym ładowarki kołowej. Na przedmiotowej przekładni zaprezentowano schematy kinematyczne na poszczególnych stopniach przełożenia. Stosując odpowiednie wartości liczbowe współczynników przesunięcia zarysu (współczynników korekcji) rozważano zazębienie dwustronne normalne, zazębienie jednostronne przedbiegunowe oraz zazębienie jednostronne pozabiegunowe. W każdym z trzech rodzajów zazębienia dokonano obliczeń naprężeń kontaktowych oraz poślizgów międzyzębnych dla każdej pary zębatej i na każdym stopniu przełożenia, stosując autorski program komputerowy z optymalizacją wielokryterialną.
EN
The paper includes preliminary considerations on the possibility of correlating results of radiation disturbances emissions’ measurements from sources of disturbances present in tunnels (especially of underground mines). On the one hand, the proposed approach is to detect sources of interference by correlating the measurements results with the simulation results. On the other hand, a correction factor for the initial evaluation of devices generating disturbances in the tunnels is to be derived.
PL
W niniejszym artykule zawarte zostały wstępne rozważania nad możliwością korelacji wyników pomiarów emisji zaburzeń promieniowanych od źródeł zaburzeń pracujących w tunelach (w szczególności w tunelach podziemnych kopalń). Zawarto propozycje podejścia do tematu poszukiwań źródeł zakłóceń poprzez korelowanie wyników pomiarów z wynikami symulacji oraz poprzez wyznaczanie współczynnika pozwalającego na wstępne ocenianie urządzeń generujących zaburzenia a pracujących w tunelach.
PL
W artykule przedstawiono pomiar strumienia przepływu przepływomierzem ultradźwiękowym za kolanem rurociągu. W odległościach do piętnastu średnic rurociągu zmierzono prędkości wody, a następnie wyznaczono współczynniki poprawkowe eliminujące błędy systematyczne związane ze zbyt krótkimi odcinkami prostymi przed przepływomierzem. Pokazano również, że modelując przepływ można również wyznaczyć te współczynniki z błędem nie przekraczającym 2%.
EN
In this article are presented the stream flow measurement behind the pipe’s elbow using ultrasonic flow meter. At distances up to fifteen pipe diameters, water velocities were measured and correction factors were calculated to eliminate systematic errors associated with too short straight sections before the flow meter. Also shown that by modeling the flow it is possible to determine these coefficients with an error not exceeding 2%.
PL
W pracy przedstawiono rezultaty pomiarów przepływu wykonanych przy użyciu przepływomierza ultradźwiękowego w rurociągu, w którego skład wchodziło kolano hydrauliczne (łuk hamburski). Do przeprowadzenia pomiarów wykorzystano przepływomierz ultradźwiękowy z głowicami nakładanymi, które ustawiono zgodnie z układem typu Z. Dokonano pomiarów przepływu za zaburzeniem, spowodowanym przez kolano hydrauliczne, dla 12 różnych kątów ustawień głowic przepływomierza w 16 odległościach od kolana hydraulicznego. Wyniki pomiarów porównano z wartościami prędkości obliczonymi przy wykorzystaniu równań 12 modeli prędkości bazujących na równaniu Prandtla. Dla celów porównawczych przeprowadzono także symulację przepływu w warunkach wykonania pomiarów w programie ANSYS CFX. Stwierdzono, że przy odpowiednim układzie głowic przepływomierza ultradźwiękowego możliwe jest wykonanie pomiaru strumienia przepływu zaburzonego przez kolano hydrauliczne w dowolnej odległości od źródła zaburzenia przy zastosowaniu odpowiedniego współczynnika korekcyjnego, wyznaczonego z równania właściwego modelu prędkości.
EN
The results of flow measurements, using an ultrasonic flowmeter in a pipeline consisting hydraulic elbow, have been discussed in this paper. Ultrasonic flowmeter with overlapping heads, which were set to the Z-system, were used for the measurements. Flow measurements with the disturbance caused by the hydraulic elbow for the 12 different flowmeter heads locations were made. The results were compared with speed values calculated using the 12 different speed models based on Prandt equation. For the comparative purposes, a simulation of flow in Ansys CFX program was also made. It has been found that with a suitable position of flowmeter head it is possible to measure a stream flow disturbed by the hydraulic elbow at any distance from the disturbance source using the appropriate correction factor from the equation of the appropriate speed model.
PL
W artykule przedstawiono wyniki oceny wpływu parametrów otoczenia (temperatury i ciśnienia) na napełnienie cylindrów silnika spalinowego. Dane do oceny wyznaczono na podstawie badań modelowych silnika o zapłonie samoczynnym. Masy powietrza zamknięte w przestrzeni roboczej cylindra, dla różnych wartości parametrów otoczenia, obliczono przy zastosowaniu modelu matematycznego opartego na równaniach Naviera-Stokesa. Symulacje wykonano całego zakresu prędkości obrotowych wału korbowego silnika. Wyniki badań modelowych zaprezentowano jako zależności współczynnika napełnienia w funkcji temperatury i ciśnienia otoczenia dla stałej prędkości obrotowej. Wyznaczone równania linii trendu stanowią tym samym zależność do obliczenia współczynnika korekcji dla współczynnika napełnienia.
EN
The article presents the results of assessing the impact of environmental parameters (temperature and pressure) to fill a cylinder internal combustion engine. Data for the assessment determined on the basis of the model diesel engine. The masses of air enclosed in the working space of the cylinder, for different values of the environmental parameters were calculated using a mathematical model based on the Navier-Stokes. Simulations were performed throughout the speed range of the engine. Model results are presented as depending on the filling factor as a function of ambient temperature and pressure for constant speed. Designated trend line equation are the same relationship to calculate a correction factor for the fill factor.
EN
The work presents the components of solar radiation that reaches the horizontal plane and a method of determining the energy value of the radiation that reaches the surface of a photovoltaic receiver inclined to the ground line at a certain angle. A shading assessment diagram and a methodology for determining the vertical angles and the influence of the horizon on the shading of a PV receiver were provided. A method of determining the direct radiation correction factor depending on the horizon line was presented. The influence of light shading on the current and voltage characteristics of a solar module was determined.
PL
W pracy przedstawiono składowe promieniowania słonecznego docierającego do powierzchni horyzontalnej oraz sposób wyznaczenia wartości energii promieniowania padającej na powierzchnię odbiornika fotowoltaicznego nachylonego pod pewnym kątem do ziemi. Zamieszczono diagram oceny cieniowania oraz metodykę wyznaczenia kątów pionowych i wpływu horyzontu na cieniowanie odbiornika PV. Przedstawiono sposób wyznaczania współczynnika korekcyjnego promieniowania bezpośredniego wywołanego linią horyzontu. Określono wpływ słabego cienia na charakterystykę prądowo-napięciową modułu solarnego.
EN
Lead 210Pb, an element of the natural uranium radioactive decay series, is not currently considered a source of radiation risk, especially in a radiation protection system in underground mines in Poland. However, it could be a completely independent element of the radioactive series due to its physical and chemical properties. Routine measurements showed significantly higher than expected concentrations of 210Pb in underground radium rich sediments, based only on the radioactive decay law. This phenomenon implies a need of 210Pb concentration monitoring in such sediments. Nevertheless, the laboratory analysis of 210Pb by gamma radiation spectroscopy is connected with a particular hindrance, the self-attenuation of 210Pb radiation in samples. Current work describes a practical method for obtaining the self-attenuation correction factor in the case of 210Pb concentration analysis. Experimentally obtained correction factors range between 0.51–6.96 cm2/g. Neglecting this factor can cause a significant error or underestimations in radiological risk assessment.
PL
Izotop 210Pb, element naturalnego szeregu promieniotwórczego 238U, jak dotąd nie był uwzględniany przy ocenie ryzyka zagrożenia radiacyjnego, szczególnie w odniesieniu do systemu ochrony radiologicznej w podziemnych zakładach górniczych (Rozporządzenie 2002) czy kontroli narażenia radiacyjnego związanego z wydobyciem oraz przetwórstwem ropy i gazu (Radiation... 1999). Okazuje się jednak, że ze względu na swoje właściwości fizykochemiczne nuklid ten może zachowywać się zupełnie niezależnie od pozostałych elementów szeregu, w którym występuje. Wyniki badań prowadzonych w ramach rutynowej kontroli zagrożenia radiacyjnego w podziemnych zakładach górniczych świadczą o tym, że dla większości osadów dołowych, powstających na skutek współstrącenia radu i baru w postaci siarczanu radowo-barowego, obserwuje się znacznie wyższe jego stężenia, niż wynikałoby to z samego tylko rozpadu 226Ra. Implikuje to konieczność monitorowania stężenia 210Pb w tych osadach, co jest związane z wieloma trudnościami analitycznymi i pomiarowymi. Niniejszy artykuł poświęcony jest wyznaczaniu współczynnika poprawkowego związanego ze zjawiskiem samoabsorpcji w próbkach stałych podczas oznaczania 210Pb metodą spektrometrii promieniowania gamma. Uzyskane współczynniki wahały się w granicach 0,51–6,96 cm2/g, co dowodzi, że nieuwzględnienie poprawki na samoabsorpcję, może prowadzić do poważnych błędów i niedoszacowań w ocenie zagrożenia radiacyjnego.
PL
W pracy przedstawiono wpływ błędnego połączenia obwodów wtórnych przekładników prądowych na działanie i wskazania układu pomiarowo-rozliczeniowego energii elektrycznej. Uziemienie końców uzwojeń stron wtórnych przekładników prądowych zamiast początków skutkuje zmianą rozpływu prądów w torach prądowych licznika. Przeanalizowano sposób określenia współczynnika korek-cyjnego dla błędnie połączonego układu oraz wielkości mających wpływ na jego wartość.
EN
Influence of incorrect connection of current transformer secondary circuits in Aron circuit on the operation of 3-phase electronic meas-uring and billing system of electrical energy in this paper has been described. Grounding the ends of secondary windings of current transformers instead of beginnings ones causes the current flow change in the measuring system, what was never reported before. Such a mistake connection can happen during the energy meter installation, and is difficult to the detection. It results in significant change of measurement results, lowering the cost of energy to be paid. The explanation of the grounding connection influence into measurement results is given in the paper. The correction factor for long time working incorrectly grounded system is calculated.
EN
Brake squeal is a disruptive high frequency noise generated by friction-induced self excited vibrations of the brake system. Great effort is spent on the improvement of brake squeal prediction reliability, using mathematical-mechanical simulation models. In this context friction material properties are one of the decisive factors for the successful brake squeal simulation. Because of the nonlinear and load dependent friction material behavior, it is mandatory to identify friction material properties under squeal typical loading conditions. For this reason a measurement method reproducing squeal typical operating conditions is under development by the authors’ research group. The present paper shows the actual development stage of this measuremet method, presenting the dynamic compression test rig, estimated friction material characteristics, and emphasizing important influence factors on the dynamic compression measurement results. In this context a particular focus is set on the derivation of correction factors when converting the measured stiffness of specimens with restriced dimensions and boundary conditions into material stiffness.
PL
Autorzy proponują sposób weryfikacji współczynnika przewodzenia ciepła zasolonych materiałów ściennych za pomocą współczynnika poprawkowego, uwzględniającego rodzaj soli oraz zawartość soli i wilgoci w materiale.
EN
The authors propose a method for verifying the heat conduction coefficient of saline wall materials, using a correction factor which takes into account the type of salt and the content of salt and humidity in the material.
EN
Of major concern are the self-absorption correction factors Cs in precise gamma-ray spectrometry of environmental samples. The overview of Cs determination methods (experimental, Monte Carlo calculations, analytical function application) is presented. Among several available methods, the author chose the one proposed by Debertin where the uncertainty level of Cs correction factor is 1÷2%. The point-like detector model is assumed whilst its efficiency is taken to be proportional to the weighted sum (integral) of the number of photons coming from sample volume elements. Computer program was developed to support the computation of Cs by the Debertin's method for samples in cylindrical geometries and Marinelli beakers. The input data are sample dimensions, density and the mass attenuation coefficient. The Cs uncertainty due to an arbitrarily chosen position of a point-like detector would not exceed 1% for the considered photon energies and the sample density range. Utilising this computer program, the relationships Cs(E,ń) were obtained for the applied geometries and a SiO2 matrix to support routine measurements. The SiO2 matrix is widely encountered in environmental spectrometry. This relationship was derived by fitting the computed data with the function Cs(E,ń) in the form proposed by Bolivar. It was shown that while handling this function to samples with the H2O matrix, the error involved in estimations would not exceed 3%.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.